Hostname: page-component-74656f9884-rdgjk Total loading time: 0 Render date: 2026-11-08T15:20:06.086Z Has data issue: false hasContentIssue false

Transcatheter creation of a pulmonary artery to left atrial fenestration in a failing Fontan circulation using the Atrial Flow Regulator (AFR)

Published online by Cambridge University Press:  26 March 2021

Emma Pascall*
Affiliation:
Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s & St Thomas NHS Foundation Trust, London, UK
Matthew I. Jones
Affiliation:
Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s & St Thomas NHS Foundation Trust, London, UK
Alexandra Savis
Affiliation:
Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s & St Thomas NHS Foundation Trust, London, UK
Eric Rosenthal
Affiliation:
Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s & St Thomas NHS Foundation Trust, London, UK
Shakeel A. Qureshi
Affiliation:
Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s & St Thomas NHS Foundation Trust, London, UK
*
Author for correspondence: Dr Emma Pascall, Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s & St Thomas NHS Foundation Trust, London, UK. Tel: +44 02071887188; Fax: 02071884556. E-mail: e.pascall1@nhs.net
Rights & Permissions [Opens in a new window]

Abstract

Transcatheter creation of an interatrial communication using the Occlutech Atrial Flow Regulator Device for pulmonary hypertension or heart failure is well described. We report a case of an 8-year-old boy with a failing Fontan circulation, in whom the Atrial Flow Regulator was used to successfully create a fenestration between the pulmonary artery and left atrium, improving his clinical condition.

Information

Type
Brief Report
Copyright
© The Author(s), 2021. Published by Cambridge University Press
Figure 0

Figure 1. Occlutech Atrial Flow Regulator device.

Figure 1

Figure 2. (a) Angiogram performed via femoral venous access with catheter placed in lateral tunnel showing no flow through the baffle stent with contrast injection (indicated by ^); (b) Angiogram after Atlas balloon dilation of the neofenestration demonstrating no extravasation of contrast; (c) and (d) Angiogram performed via femoral venous access with catheter in lateral tunnel showing Atrial Flow Regulator device and flow through it with contrast injection; (e) Transoesophageal echocardiogram during the procedure showing Atrial Flow Regulator device with good flow through the device; (f) Transthoracic echocardiogram the day after the procedure showing Atrial Flow Regulator device with good flow through the device.