RADIOCARBON ANALYSIS AND STATUS REPORT FROM TÜRKIYE: 1MV NATIONAL AMS LABORATORY (TUBITAK-AMS)

Published online by Cambridge University Press:  10 March 2023

Turhan Doğan*
Affiliation:
TÜBİTAK, Marmara Research Center, Climate Change and Sustainability Vice Presidencies, 41470, Gebze, Kocaeli, Türkiye
Erhan İlkmen
Affiliation:
TÜBİTAK, Marmara Research Center, Climate Change and Sustainability Vice Presidencies, 41470, Gebze, Kocaeli, Türkiye
Furkan Kulak
Affiliation:
TÜBİTAK, Marmara Research Center, Climate Change and Sustainability Vice Presidencies, 41470, Gebze, Kocaeli, Türkiye
*
*Corresponding author. Email: turhan.dogan@tubitak.gov.tr
Rights & Permissions [Opens in a new window]

Abstract

In autumn of 2016, the National 1MV Accelerator Mass Spectrometry (AMS) Laboratory at The Scientific and Technological Research Council of Türkiye (TÜBİTAK), Marmara Research Center (MRC), Türkiye (Turkey), started to offer radiocarbon (14C) analysis service internationally. In this article, the process from sample acceptance to reporting and the primary procedures implemented and applied for 14C analysis at the TÜBİTAK AMS Radiocarbon Dating Laboratory are described. The service provided by the laboratory includes sample evaluation for 14C analysis, sample preparation, graphite production, AMS measurement, data supervision, calendar date calculations, and consultancy. For commercial testing and analysis, a one-page official report which shows the 14C age and uncertainty is provided for each sample. In addition to a dedicated wet chemistry laboratory to process samples before measurement with AMS, there are two systems for the conversion of CO2 to elemental carbon process; an automated graphitization system (AGE III) and a manual graphitization system based on a glass high vacuum line. A 1MV UAMS NEC Pelletron system installed in the laboratory is used for natural level 14C samples needed to be analyzed for archeological, geological, geographical, and environmental and forensic science applications. In addition to commercial 14C testing and analysis activities, national and international research projects can be developed or contributed to within the scope of project management or partnership.

Information

Type
Research Article
Copyright
© The Author(s), 2023. Published by Cambridge University Press for the Arizona Board of Regents on behalf of the University of Arizona
Figure 0

Table 1 A checklist of quality control parameters for checking collagen presence in bone samples.

Figure 1

Table 2 Quality control parameters for extracted collagen (after DeNiro 1985; van Klinken 1999).

Figure 2

Table 3 The IAEA standard reference materials used and their obtained values from the earliest measurements during acceptance tests in 2015. The results given in this table were significant parameters for the first performance of the AGE III and TÜBİTAK 1MV AMS systems and their integration with each other. All measured values are achieved with a single cathode. Uncertainties of the measured value (pMC) are calculated as standard deviations of the mean.

Figure 3

Table 4 AMS measurement results of SIRI intercomparison samples.