Evaluation of coaxial cable performance under thermal gradients

Published online by Cambridge University Press:  30 March 2015

Sergio Colangeli*
Affiliation:
Department of Electronic Engineering, University of Rome Tor Vergata, via del Politecnico 1, 00133 Rome, Italy. Phone: +39 7259 7343
Riccardo Cleriti
Affiliation:
Department of Electronic Engineering, University of Rome Tor Vergata, via del Politecnico 1, 00133 Rome, Italy. Phone: +39 7259 7343
Walter Ciccognani
Affiliation:
Department of Electronic Engineering, University of Rome Tor Vergata, via del Politecnico 1, 00133 Rome, Italy. Phone: +39 7259 7343
Ernesto Limiti
Affiliation:
Department of Electronic Engineering, University of Rome Tor Vergata, via del Politecnico 1, 00133 Rome, Italy. Phone: +39 7259 7343
*
Corresponding author: S. Colangeli Email: colangeli@ing.uniroma2.it
Rights & Permissions [Opens in a new window]

Abstract

This paper presents a very flexible tool for numerically evaluating the small-signal and noise parameters of a transmission line subject to an arbitrary thermal gradient. Contrary to previous methods, the proposed approach allows straightforwardly taking into account possible variations of electrical parameters along the propagation direction, such as may be expected when temperature ranges between very different values. The main application of the proposed method is cable modeling in noise-figure measurement setups under cryogenic operation: in such circumstances, indeed, the coaxial cables (or waveguide) at the interface between the outside and the inside of the cryogenic chamber are subject to remarkable temperature excursions. As a consequence, significant de-embedding errors may arise if the cables are not correctly modeled, given the very low values of noise figure which are commonly exhibited by cryo-cooled active devices.

Information

Type
Research Papers
Copyright
Copyright © Cambridge University Press and the European Microwave Association 2015 
Figure 0

Fig. 1. Telegrapher's representation of an elementary section of transmission line. (a) Infinitesimal cell. (b) Discrete cell, with noise sources.

Figure 1

Fig. 2. Sample measured S-parameters in magnitude of a coaxial cable at ambient temperature and under a 150°C thermal excursion. Measurements are carried out by the unterminating method. In the bottom, axis are also shown (cross-markers) the magnitude of S12 under thermal excursion as derived from S12 at ambient temperature through the approach described in Section IV, as well as (dashed line) the difference between measured and estimated magnitude of S12. Normalization impedance is 50 Ω.

Figure 2

Fig. 3. Comparison between the general-purpose approach Section III and the simplified approach of Section IV in computing the noise factor of an ideal coaxial cable on a fixed source termination.

Figure 3

Table 1. Cable parameters used to generate the results of Fig. 3.

Figure 4

Fig. 4. Computed primary parameters of commercial coaxial cables, for temperatures from 25 K (lowest curves) to 298 K (highest curves). Left: Be–Cu cable. Right: steel cable.

Figure 5

Fig. 5. Flow charts illustrating the steps to apply the proposed numerical approaches. Subfigure (a) provides an overview of the general-purpose and simplified algorithms; the dashed arrow applies optionally, and only in case the simplified algorithm is adopted. The dashed box can be expanded as shown in subfigure (b), in case the technique of Section IV is used to estimate the S-parameters of the cable under cryogenic gradient.

Figure 6

Fig. 6. Picture of the custom cryogenic probe station.

Figure 7

Fig. 7. Comparisons of cable loss at ambient temperature (lower curves) and under a 150°C thermal excursion (higher curves). Dotted curves are completely based on simulations. Of the other two curves, that at ambient temperature is measured, whereas that under thermal gradient is derived from the former based on the approach described in Section IV. Normalization impedance is 50 Ω.

Figure 8

Fig. 8. Comparisons of cable noise figure at ambient temperature and under a 150°C thermal excursion. The ambient-temperature measurement is derived from S-parameters. Of the two curves under thermal gradient, the continuous one is obtained by the direct cold-source measurement, whereas the dotted one is derived based with the approach described in Section IV.