Secondary fragmentation and relative biological effectiveness (RBE) study using Bridge SOI microdosimeter: Monte Carlo simulation

Published online by Cambridge University Press:  09 January 2024

C. K. Ying*
Affiliation:
Department of Biomedical Imaging, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Bertam, Penang, Malaysia
M. Arif Efendi
Affiliation:
Department of Nuclear Engineering and Engineering Physics, Faculty of Engineering, Universitas Gadjah Mada, Yogyakarta, Indonesia
Susanna Guatelli
Affiliation:
Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia
Linh T. Tran
Affiliation:
Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia
David Bolst
Affiliation:
Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia
*
Corresponding author: C. K. Ying; Email: ckying7@usm.my
Rights & Permissions [Opens in a new window]

Abstract

Introduction:

This work calculates the microdosimetric spectra and evaluates the relative biological effectiveness (RBE10) of oxygen and carbon ions using Monte Carlo simulation. This study presents a fast, reliable radiation field characterisation and accurate biological dose prediction tool in charged particle therapy for heavy-ion beams using the Bridge silicon-on-insulator (SOI) microdosimeter via Tool for Particle Simulation (TOPAS)-based simulations toolkit.

Method:

The study used the TOPAS simulation to model the Bridge SOI microdosimeter and study its response to carbon beams with an energy of 290 MeV/u and oxygen beams with an energy of 345 MeV/u. Dose-mean lineal energy values $(\overline {{y_D})\;} $and RBE10 values were evaluated using microdosimetric lineal energy spectra with the MKM model.

Results and Conclusions:

The results demonstrate that oxygen ion beams have an advantage for cancer treatment as they provide higher RBE10 values and occur at the same positions as the maximum physical dose (Bragg peak), compared to carbon ion beams. The study provides new understanding of RBE for carbon and oxygen ions, as well as the relationship between physical doses and RBE.

Information

Type
Original Article
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2024. Published by Cambridge University Press
Figure 0

Figure 1. The geometry of the silicon-on-insulator detector (Source: Zhu et al. [15])

Figure 1

Figure 2. The geometry of the mini-tissue equivalent proportional counters (Source: Zhu et al. [15])

Figure 2

Figure 3. Relative absorbed dose profile in water phantom per incident particle for 290 MeV/u 12C (red) and 345 MeV/u 16O (blue) ion beams

Figure 3

Figure 4. Simulated microdosimetric spectra for a 290 MeV/u 12C beam at 20, 80, 120, 158, 159, 160, 161 162 and 165 mm depth in water

Figure 4

Figure 5. Simulated microdosimetric spectra for a 290 MeV/u 12C beam at 200, 250, 260 and 280 mm depth in water

Figure 5

Figure 6. Simulated microdosimetric spectra for a 345 MeV/u 16O beam at 20, 80, 120, 158, 159, 160, 161 and 162 mm depth in water

Figure 6

Figure 7. Simulated microdosimetric spectra for a 345 MeV/u 16O beam at 163, 164, 165, 180, 200 and 250 mm depth in water

Figure 7

Figure 8. Simulated $\overline {{y_D}} $ profile obtained with the Bridge SOI microdosimeter for (a) 290 MeV/u 12C and (b) 345 MeV/u 16O ion beam

Figure 8

Table 1. Comparison of the entrance $\overline {{{\rm{y}}_{\rm{D}}}} {\rm{\;}}$value and maximum $\overline {{{\rm{y}}_{\rm{D}}}} {\rm{\;}}$value for 12C between measurement by Tran et al. [9] and simulation in this study

Figure 9

Table 2. Comparison of relative biological effectiveness values for 12C and 16O ions

Figure 10

Figure 9. Simulated RBE10 distribution obtained with the Bridge SOI microdosimeter for (a) 290 MeV/u 12C and (b) 345 MeV/u 16O ion beam

Figure 11

Figure 10. Comparison of simulated RBE10 profile obtained with the Bridge SOI microdosimeter for 290 MeV/u 12C and 345 MeV/u 16O ion beams

Figure 12

Figure 11. Simulated RBE10 distribution obtained with the Bridge SOI microdosimeter and mini-TEPC for (a) 290 MeV/u 12C and (b) 345 MeV/u 16O ion beam

Figure 13

Figure 12. Secondary fragments contributing to the microdosimetric spectrum obtained with the Bridge SOI micrpdosimeter for 290 MeV/u 12C ion beam set at 20 mm depth (a) log-log scale (b) semi-log scale

Figure 14

Figure 13. Secondary fragments contributing to the microdosimetric spectrum obtained with the Bridge SOI micrpdosimeter for 290 MeV/u 12C ion beam set at 160 mm depth (a) log-log scale (b) semi-log scale

Figure 15

Figure 14. Secondary fragments contributing to the microdosimetric spectrum obtained with the Bridge SOI micrpdosimeter for 290 MeV/u 12C ion beam set at 250 mm depth (a) log-log scale (b) semi-log scale

Figure 16

Figure 15. Secondary fragments contributing to the microdosimetric spectrum obtained with the Bridge SOI micrpdosimeter for 345 MeV/u 16O ion beam set at 20 mm depth (a) log-log scale (b) semi-log scale

Figure 17

Figure 16. Secondary fragments contributing to the microdosimetric spectrum obtained with the Bridge SOI micrpdosimeter for 345 MeV/u 16O ion beam set at 160 mm depth (a) log-log scale (b) semi-log scale

Figure 18

Figure 17. Secondary fragments contributing to the microdosimetric spectrum obtained with the Bridge SOI micrpdosimeter for 345 MeV/u 16O ion beam set at 50 mm depth (a) log-log scale (b) semi-log scale