Transport of intense beams with current-dependent initial conditions in linearly tapered solenoid channels

Published online by Cambridge University Press:  21 October 2019

J. R. Harris*
Affiliation:
Air Force Research Laboratory, Albuquerque, NM87117, USA
*
Author for correspondence: J. R. Harris, Kirtland Air Force Base, 3550 Aberdeen Ave. SE, Albuquerque, NM87117, USA.

Abstract

In electron beams where space charge plays an important role in the beam transport, the beams’ transverse and longitudinal properties will become coupled. One example of this is the transverse–longitudinal correlation produced in a current-modulated beam generated in a DC electron gun, formed through the competition between the time-dependent radial space charge force and the time-independent radial focusing force. This correlation will cause both the slice radius and divergence of the beam extracted from the gun to depend on the slice current. Here we consider the transport of such a beam in a linearly tapered solenoid focusing channel. Transport performance was generally improved with longer taper lengths, minimal initial correlation between slice divergence and slice current, and moderate degrees of initial correlation between initial slice radius and slice current. Performance was also generally improved with lower slice emittances, although surprisingly transport was improved by slightly increasing the assumed slice emittance in certain limited circumstances.

Information

Type
Research Article
Copyright
Copyright © Cambridge University Press 2019
Figure 0

Fig. 1. Initial transverse–longitudinal correlations and well-confined beams. (a) An electron beam is generated with a current which varies along its length, from “zero current” at the beam ends (blue) to a peak current somewhere between those ends (red). (b) The competition between transverse space charge and focusing forces in the gun introduces a correlation between the radius, divergence, and current in each slice of the beam. (c) With longitudinal evolution in the beam neglected, each slice of the beam independently evolves in radius and divergence as it propagates along the transport channel [here, a thin-lens periodic solenoid channel rather than the uniform focusing channel of Harris et al. (2013)]. (d) In this case, the “zero current” slice is strongly mismatched to the channel, so that its radius eventually exceeds that of the peak-current slice. The “zero current” slice, and therefore the overall beam, are considered “not well-confined,” while the remaining slices are all “well-confined.”

Figure 1

Fig. 2. Relationship of slice initial conditions to the parameters a1 and b1. (a) A current-modulated beam consists of multiple slices, each of which is thin enough to be approximated as having a single current. This current varies from “zero” at the ends (blue) to a maximum value somewhere else in the beam (red). Each slice is assumed to be injected into the channel with a radius and divergence which is linearly dependent on that slice's current. In this paper, the beam is assumed to be created from an idealized Pierce gun, which always provides an initial radius of 5 mm and zero divergence for the peak current slice. (b) a1 = b1 = 0, providing no variation of initial radius or divergence on slice current. (c) a1 = 0, b1 > 0, providing no dependence of initial radius on slice current, but some dependence of initial divergence on slice current. (d) a1 > 0, b1 = 0, providing some dependence of initial radius on slice current, but no dependence of initial divergence on slice current. (e) a1 > 0, b1 > 0, providing some dependence of both initial radius and divergence on slice current. The values of a1 and b1 can also be considered to define the magnitude of projected emittance in the injected beam, as described in Harris et al. (2013)

Figure 2

Fig. 3. Focusing channel strength [km(z)] as a function of position z downstream in the channel (left), and the resulting local matched beam radius as a function of position for a 100 mA, 10 keV electron beam (right), for the linear taper with A = 0 m and B = 2.5 m, and taper strengths C of 2 (dash), 1 (solid), and 0.5 (dotted).

Figure 3

Fig. 4. Example of beam transport in a tapered channel. Beam envelopes for 10 keV electron beams injected with currents of 100 mA (red); 75, 50, and 25 mA (black); and 0 mA (blue) into a linearly tapered solenoidal focusing channel with parameters A = 0 m, B = 2.5 m, and C = 2. The beam slices are injected with initial correlations between slice current, radius, and divergence of (0 m/A, 0 A−1) (top), (0.03 m/A, 0 A−1) (middle), and (0.03 m/A, 0.04 A−1) (bottom). The cases with increased initial correlation between slice radius and slice current have much-improved transport and are well confined over the 5 m channel length.

Figure 4

Fig. 5. Linear taper results. Matrix sum as a function of taper strength (C) for several values of taper length (B).

Figure 5

Fig. 6. Linear taper results. Column sum as a function of taper strength (C) for several values of taper length (B) and initial divergence–current correlation (b1). The maximum indicated value of the column sum is 125, slightly less than the theoretical maximum value of 126 (21 values of current  × 6 values of a1). This difference is due to incorrect handling of the zero current slice in the a1 = 0.05 m/A case, as discussed in the text.

Figure 6

Fig. 7. Slice envelopes for three transport conditions near C = 1.

Figure 7

Fig. 8. Slice envelopes for three transport conditions near C = 0.5.

Figure 8

Fig. 9. Linear taper results. Row sum as a function of taper strength (C) for several values of taper length (B) and initial radius–current correlation (a1). Values of 0.03 and 0.04 m/A are preferred over the entire range of channel taper values C, with 0.03 m/A generally being preferred but with 0.04 m/A being preferred for intermediate values of B at very high values of C.

Figure 9

Fig. 10. Effect of beam emittance. Matrix sum as a function of linear taper strength C for taper lengths B of 5 m (solid circles) and 0.1 m (hollow squares), for slice emittances of 1 µm (blue), 5 µm (red), and 10 µm (black).

Figure 10

Fig. 11. Effect of beam emittance. Each panel shows the column sum from Eq. (6) corresponding to a single value of b1.

Figure 11

Fig. 12. Effect of beam emittance. Each panel shows the row sum from Eq. (6) corresponding to a single value of a1.

Figure 12

Fig. 13. Number of well-confined slices as a function of slice emittance and taper strength for the long linearly tapered channel, with a1 = 0.04 m/A.

Figure 13

Fig. 14. Impact of slice current and slice emittance on transport effectiveness for the conditions indicated at right. Green indicates well-confined transport, while red indicates non-well-confined transport.

Figure 14

Fig. 15. Impact of slice current and slice emittance on transport effectiveness for the conditions indicated at right. (a) Average radius of lower-current slices is generally significantly less than that of the peak-current slice in the 1 µm case. (b) This is not true for the 75 mA, and other higher current slices, whose mismatch oscillations are out of phase with that of the peak current slice. (c) These facts combine to enable non well-confined transport for the higher current slices at 1 mm, although the excursions beyond the peak current slice radius are very small. (d) When the emittance is increased to 12 µm, the higher current slices are now more closely in phase with the peak current slice, reducing the opportunity for non well-confined transport, and accounting for the initial improvement in transport indicated in Figure 14 as emittance is increased. (e) Increasing emittance has also caused the mid-current slices to both shift phase and to increase their average radii, causing them to become non well confined. (f) At 12 µm, the lower current slices still have radii which are smaller than the waists of the peak current slice, so their transport is initially still well confined. (g) Moving to still higher emittances, the higher current slices have now continued their phase shifting relative to the peak current slice, to the point where they are beginning to experience non well-confined transport. (h) Increasing values of emittance also now lead to larger average radii for the lower-current slices, opening the opportunity for non well-confined transport with them as well.

Figure 15

Fig. 16. Comparison of linear and ellipsoidal correlations between slice current and slice radius for different values of a1, according to Eq. (1). Note that values of 0.03 m/A generally provide the best match between the linear model and the ellipsoidal model, but under more extreme values of reduced current, values closer to 0.04 m/A may be preferred. This mirrors the results of row sum calculations where 0.03 m/A is generally preferred but in extreme cases, 0.04 m/A is preferred. Note also the greatly improved performance in Figure 8 for a1 = 0.03 m/A.

Figure 16

Fig. 17. (Top) Beam envelopes for 100 mA (red); 75 mA, 50 mA, and 25 mA (black); and 25 mA (blue) slices; for the indicated conditions, as shown previously in Figure 8. (Bottom) The same envelopes, but now assuming injection of a beam with $r \sim \sqrt I$,r′ = 0, and with zero emittance. With emittance increased to 1 µm, this panel looks identical except that very small currents approaching zero become nonphysical due to their being injected with a theoretical radius of zero which yields an infinite emittance-driven impulse. This emphasizes the similarity of a1 = 0.03 m/A to the ideal case for transport.