Comparison of 14C Collected by Precipitation and Gas-Strip Methods for Dating Groundwater

Published online by Cambridge University Press:  30 March 2016

Kotaro Nakata*
Affiliation:
Nuclear Fuel Cycle Backend Research Center, Abiko Research Laboratory, Central Research Institute of Electric Power Industry, 1646 Abiko, Abiko-shi, Chiba-ken 270-1194, Japan.
Takuma Hasegawa
Affiliation:
Nuclear Fuel Cycle Backend Research Center, Abiko Research Laboratory, Central Research Institute of Electric Power Industry, 1646 Abiko, Abiko-shi, Chiba-ken 270-1194, Japan.
Teruki Iwatsuki
Affiliation:
Tono Geoscience Center, Japan Atomic Energy Agency, 1-64, Yamanouchi, Akeyo, Mizunami, Gifu, 509-6132, Japan.
Toshihiro Kato
Affiliation:
Tono Geoscience Center, Japan Atomic Energy Agency, 1-64, Yamanouchi, Akeyo, Mizunami, Gifu, 509-6132, Japan.
*
*Corresponding author. Email: k-nakata@criepi.denken.or.jp.
Rights & Permissions [Opens in a new window]

Abstract

Dissolved inorganic carbon (DIC) in groundwater is used to estimate the residence time based on radiocarbon concentration. DIC is usually extracted by a gas-strip or precipitation (SrCO3 or BaCO3) method. In this study, the gas-strip and precipitation methods of DIC were applied to both artificially prepared NaHCO3 solutions and natural groundwater to estimate the certainty of the two methods for 14C dating. 14C values obtained by the gas-strip method for NaHCO3 solutions with distinct salinity, DIC, and 14C concentrations were close to the theoretically predicted 14C value based on the 14C value of NaHCO3 powder. Conversely, the 14C value obtained by the precipitation method always showed higher values than the predicted values. The difference in 14C value between the gas-strip and precipitation methods was assumed to be caused by the contamination of modern carbon in the NaOH solution used in the precipitation method. The contamination of modern carbon derived from the NaOH solution during precipitation was found to range from less than 1 mg/L to about 1 mg/L. The applicability of the precipitation method for groundwater should be considered carefully according to the DIC, 14C concentration of groundwater, and purpose of the study being conducted.

Information

Type
Research Article
Copyright
© 2016 by the Arizona Board of Regents on behalf of the University of Arizona 
Figure 0

Table 1 Solutions for preliminary comparison of 14C values obtained by the two preparation methods.

Figure 1

Figure 1 Gas-strip line to extract DIC from groundwater

Figure 2

Figure 2 Groundwater sampling point at Mizunami underground research laboratory

Figure 3

Table 2 Comparison of measured 14C and possible ranges of 14C for NaHCO3 solutions.

Figure 4

Table 3 Background DIC concentration of solutions used for precipitation method.

Figure 5

Table 4 Comparison of 13C and 14C of groundwater samples prepared by gas-strip and precipitation methods.

Figure 6

Figure 3 Error in 14C analysis for contamination by modern carbon for groundwater with initial DIC concentrations of 0–20 mg/L. 14C value of contaminated modern carbon is assumed to be 100 pMC. (a) Contamination by modern carbon is 0.5 mg/L. (b) Contamination by modern carbon is 1 mg/L. The shaded area shows error within 10% of the known 14C value. (c) Constraint for DIC and 14C of groundwater that should be analyzed within 10% error in the case of modern carbon contamination with 0.5 and 1 mg/L.

Figure 7

Figure 4 Relationship between concentration of DIC in groundwater and expected 14C ages (14C ageex) for samples prepared by the precipitation method where groundwater 14C (14Cgw) is 10, 50, and 80 pMC. 14C ageex values were calculated using Equations 3 and 4.