Hostname: page-component-7b7567c8c-2rsb6 Total loading time: 0 Render date: 2026-11-12T06:09:37.509Z Has data issue: false hasContentIssue false

Surgical repair for aortopulmonary window with interrupted aortic arch in late childhood

Part of:Surgery

Published online by Cambridge University Press:  07 January 2020

Sachin Talwar*
Affiliation:
Cardiothoracic Center, All India Institute of Medical Sciences, New Delhi110029, India
Niwin George
Affiliation:
Cardiothoracic Center, All India Institute of Medical Sciences, New Delhi110029, India
Saurabh K. Gupta
Affiliation:
Cardiothoracic Center, All India Institute of Medical Sciences, New Delhi110029, India
Shiv K. Choudhary
Affiliation:
Cardiothoracic Center, All India Institute of Medical Sciences, New Delhi110029, India
*
Author for correspondence: Dr S. Talwar, Professor, Department of Cardiothoracic and Vascular surgery, All India Institute of Medical Sciences, New Delhi 110029, India. Tel: +91 9868398136; Fax: +91 1126588663; E-mail: sachintalwar@hotmail.com
Rights & Permissions [Opens in a new window]

Abstract

Aortopulmonary window with interrupted aortic arch is rarely reported beyond infancy. Pre-operative assessment and surgical repair are challenging. We report successful surgical repair of aortopulmonary window with interrupted aortic arch in a 6-year-old girl with near-normal pulmonary artery pressure immediately following surgery.

Information

Type
Brief Report
Copyright
© Cambridge University Press 2020
Figure 0

Figure 1.(a and b) Pre-operative images. (a) Chest X-ray showing cardiomegaly; (b) computed tomographic (CT) angiography, axial view at the level of aortopulmonary window (APW). (c and d) Reconstructed CT angiography images. (c) Anterior view showing APW. (d) Posterior view showing absent isthmus and continuity of patent arterial duct with descending thoracic aorta (DTA).

Figure 1

Table 1.Cardiac catheterisation data

Figure 2

Figure 2.(a and b) Intraoperative images. (a) Pre-repair anatomy of APW and interrupted aortic arch (IAA). The cross-clamp has been placed on the ascending aorta and the right innominate artery has been connected to the arterial circuit of CPB via 6-mm-wide polytetrafluoroethylene graft. Absence of aortic isthmus can be appreciated. (b) Post-repair image showing reconstruction of aortic arch with 16-mm-wide polytetrafluoroethylene ringed graft. (c and d) Line diagram. (c) Pre-operative anatomy. The right pulmonary artery is arising at a higher level from the aorta after the defect. (d) Post-operative anatomy; 1- polytetrafluoroethylene patch used to cover the harvest site of right PA from ascending aorta, 2- direct suture closure of quarter of aortic side of APW, 3- anastomotic line between right PA and main PA at the orifice of pulmonary side of APW, 4- suture closed pulmonary end of patent ductus arteriosus, 5- proximal anastomotic line of no-16 polytetrafluoroethylene graft with ascending aorta at the aortic side of APW, 6- distal anastomotic suture line between interposition graft and DTA.

Figure 3

Figure 3.(a and b) Post-operative CT angiography images. (a) Right PA has been implanted to main pulmonary artery and confluent patent good-sized bilateral PA can be appreciated. (b) Continuity of aortic arch with DTA has been established with 16-mm-wide polytetrafluoroethylene ringed graft. Blood flow through wide patent graft and lack of compression of nearby airways can be appreciated. (c and d) Reconstructed CT angiography images. (c) Anterior view showing repaired APW and IAA. (d) Right-sided view showing reconstructed arch with 16-mm-wide polytetrafluoroethylene ringed graft.