Hostname: page-component-7b7567c8c-wxvwp Total loading time: 0 Render date: 2026-11-16T07:41:35.639Z Has data issue: false hasContentIssue false

Anchoring and migration of balloon in REBOA

Published online by Cambridge University Press:  24 September 2021

C.C. Mei*
Affiliation:
Dept. of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
Y.L. Li
Affiliation:
Katy, TX, USA
S. Michele
Affiliation:
School of Engineering, Computing and Mathematics, University of Plymouth, Drake Circus, Plymouth PL4 8AA, UK
P. Sammarco
Affiliation:
Dept. of Civil Engineering and Computer Science, Università degli Studi di Roma ’Tor Vergata’, 00133 Roma, Italy
P.B. McBeth
Affiliation:
Trauma and Acute Care Surgery, Cumming School of Medicine, University of Calgary, Calgary, AB T3M 1M4 Canada
*
†Email address for correspondence: ccmei@mit.edu

Abstract

A mechanical theory is described for a phenomenon in the surgical procedure of resuscitative endovascular balloon occlusion of the aorta (REBOA). In this procedure a balloon is pushed into the aorta by a catheter and then inflated in order to stop haemorrhage. One of the hazards of this procedure is the tendency for the balloon to migrate away from its intended position. This work examines the mechanics of balloon anchoring and migration by analysing the effects of pressure waves, the sheet flow and solid friction in the thin gap between the walls of the aorta and balloon. A viscoelastic model is adopted for the aorta wall for pressure waves between the left ventricle and the balloon. The lubrication approximation is used for blood flow in the thin gap between the walls of the balloon and aorta. Samples of quantitative predictions are discussed on how the inflation pressure and balloon characteristics affect the balloon anchoring and migration. The crucial roles of solid friction and balloon placement are pointed out, which should help in guiding the manufacturing of balloons and their usage in the field.

Information

Type
JFM Papers
Copyright
© The Author(s), 2021. Published by Cambridge University Press
Figure 0

Figure 1.Symbolic model of REBOA.

Figure 1

Figure 2.Balloon in aorta. Solid curves: geometry under zero blood pressure. Dashed curves: after heart valve opens. Labels ($x,r$): inertial coordinates; Labels ($\xi ,\eta$): coordinates moving with balloon.

Figure 2

Figure 3.Model of pressure pulses released from a ventricle for $T_0=0$ s, $T_1=0.1$ s, $T_2=0.3$ s.

Figure 3

Figure 4.Maximum aortic pressure at the head of balloon at different $X$. Only $\beta =[1.0, 1.5, 2.0]\times 10^{-2}\ \text {s}$ are known to be representative for a human aorta.

Figure 4

Figure 5.Snapshot of gap during the advancing phase of the second pulse at $t=1.45$ s. The circular dots represent numerical results including the thin tail left by the first pulse. The hatched surface is the upstream half of balloon wall.

Figure 5

Figure 6.Snapshot of gap during the retreating phase of the second pulse at $t=1.7\ \text {s}$. The circular dots represent numerical results and the hatched surface is the upstream half of balloon wall.

Figure 6

Figure 7.Balloon movement forced by intermittent cardiac pressure and resisted by friction. Input data: $\ell = 4$ cm, $b_0 = 2$ mm, $V_b=16.185$ ml and $M = 16.3$ g. (a) Blood pressure $p(X, t)$; (b) $F=F_p+F_f$ around the peaks of pressure pulses when the balloon moves; (c) displacement of the balloon; (d) gap tip $\xi _*$.

Figure 7

Figure 8.Numerically computed balloon velocity and forces near the peak of a typical pressure pulse. (a) Pressure $p(X,t)$ (dashed curve) and gap tip $\xi _*(t)$. (b) Balloon velocity (dashed curve) and the total force on balloon $F$ (solid). (c) Viscous drag $F_{s, a_\xi }$ and $F_{s, X_t}$.

Figure 8

Figure 9.Balloon displacement for $X(0)=20$ cm and different $f$. Other inputs are the same as those in figure 7.

Figure 9

Figure 10.Balloon displacement for $f = 0.200$ and different $X(0)$. Other inputs are the same as those in figure 7.

Figure 10

Figure 11.Threshold of $\max (p(X,t))$ for fixed $X(0)=20$ cm and different balloon distention $b_0$ and friction factor $f$. Circular dots: numerical computations. Solid curve: analytical approximations.

Figure 11

Figure 12.Comparison between $\xi _*$ and $\xi _0$ for anchored balloon. Circular dots: numerically computed $\xi _*$ after eliminating $\xi _0$ in (7.8) by using (4.5). Solid curves: $max(\xi _0)$ corresponding to max$(p(X,t))$ according to (4.5).