Hostname: page-component-74656f9884-j7cmm Total loading time: 0 Render date: 2026-11-07T21:57:13.235Z Has data issue: false hasContentIssue false

Promontory osteoma mimicking otosclerosis: case report

Published online by Cambridge University Press:  27 September 2019

S Gülşen*
Affiliation:
Department of Otorhinolaryngology, Private Hatem Hospital, Gaziantep, Turkey
*
Author for correspondence: Dr Secaattin Gülşen, Department of Otorhinolaryngology, Private Hatem Hospital, Allaben District, Kemal Köker Avenue No. 41, Şahinbey/Gaziantep27000, Turkey E-mail: drsecaattingulsen@gmail.com
Rights & Permissions [Opens in a new window]

Abstract

Objective

This case report presents a middle-ear osteoma mimicking otosclerosis that was located at the promontory. The osteoma was successfully excised using an endoscopic transcanal approach without any complication.

Case report

A 21-year-old man presented with a 4-year history of progressive conductive hearing loss (47 dB with a 30-dB air–bone gap) with intermittent tinnitus of recent onset in his right ear. Endoscopic transcanal middle-ear exploration showed that an osteoma located on the promontory was restricting the mobility of the stapes by affecting the anterior crus of the stapes. After transcanal resection of the osteoma, pure tone audiometry improved to 23 dB with a 5-dB air–bone gap. Tinnitus resolved spontaneously without any additional treatment.

Conclusion

Promontory osteomas, a rare and usually asymptomatic clinical entity, should be taken into consideration in the differential diagnosis in patients with progressive conductive hearing loss and tinnitus with intact stapedial reflexes and normal otoscopic findings.

Information

Type
Clinical Records
Copyright
Copyright © JLO (1984) Limited, 2019
Figure 0

Fig. 1. Graphs showing: (a) pre-operative pure tone audiometry result of the right ear, 47 dB air-conduction threshold with 30 dB air–bone gap and Carhart's notch at a frequency of 2 kHz; (b) pure tone audiometry result of the right ear after removal of the middle-ear osteoma, 23 dB air-conduction threshold with a 5 dB air–bone gap.

Figure 1

Fig. 2. Photographs showing: (a) temporal bone high-resolution computed tomography view of the promontory osteoma (left arrow); (b) intra-operative view of the promontory osteoma with the vertical arrow showing an osteoma impinging on the anterior crus of the stapes and the horizontal arrow showing the osteoma; (c) endoscopic view of the middle ear after meticulous removal of the osteoma; and (d) haematoxylin and eosin stained specimen showing fragments of lamellar bone and normal bone tissue. (H&E; ×200)