Electrical measurements on the 2503 m Dome F Antarctic ice core

Published online by Cambridge University Press:  14 September 2017

Shuji Fujita
Affiliation:
Department of Applied Physics, Graduate School of Engineering, Hokkaido University, Sapporo 060-8628, Japan E-mail: sfujita@pmg.nipr.ac.jpNational Institute of Polar Research, Kaga, Itabashi-ku, Tokyo 173-8515, Japan
Nobuhiko Azuma
Affiliation:
Department of Mechanical Engineering, Nagaoka University of Technology, 1603-1 Kamitomioka, Nagaoka 940-2188, Japan
Hideaki Motoyama
Affiliation:
National Institute of Polar Research, Kaga, Itabashi-ku, Tokyo 173-8515, Japan
Takao Kameda
Affiliation:
Kitami Institute of Technology, 165, Koencho, Kitami 090-8507, Japan
Hideki Narita
Affiliation:
Institute of Low Temperature Science, Hokkaido University, Sapporo 060-0819, Japan
Yoshiyuki Fujii
Affiliation:
National Institute of Polar Research, Kaga, Itabashi-ku, Tokyo 173-8515, Japan
Okitsugu Watanabe
Affiliation:
National Institute of Polar Research, Kaga, Itabashi-ku, Tokyo 173-8515, Japan
Rights & Permissions [Opens in a new window]

Abstract

The 320 kyr climatic record from the 2503 m Dome Fuji (Antarctica) ice core was analyzed using two electrical methods: AC-ECM and ECM (electrical conductivity measurements). AC-ECM is a method to detect the complex admittance between electrodes dragged on the ice surface with mm-scale resolution and uses 1V and 1 MHz. the ratio of the real to imaginary part of the admittance is the AC loss factor, which responds linearly to the amount of sulfuric acid and hydrogen ions. Both the AC loss factor and the ECM current respond to acid, but the ECM signal tends to saturate at high acidities. Dome Fuji ice was measured to be highly acidic, with background values of 2–7 μM, and had 4500 major peaks with acidities of up to 90 μM. This ice-core evidence and earlier snow-chemistry survey around the dome region indicates that Dome F may have a better connection to the stratosphere than have sites at lower altitude, which allows more stratospheric aerosol and gases to reach the snow surface. Acidity tends to be high in interglacial periods, but correlation between acidity and δ18O is not straightforward. Electrical signals decreased and smoothed out with increasing depth; the diffusion coefficients deduced from this smoothing were 10–102 times greater than in solid ice. the ice core exhibited electromechanical effects and expelling effects from sulfate peaks.

Information

Type
Research Article
Copyright
Copyright © the Author(s) [year] 2002
Figure 0

Table 1.Experimental conditions for AC-ECMand ECM

Figure 1

Fig. 1An example of raw data from the AC-ECM and ECM. (a) Susceptance (dotted lines) and conductance (solid lines) from the AC-ECM. the ordinate uses a logarithmic scale. the graph shows consecutive measurements on three cores, each about 1.5 m long. Core ends are indicated by ``CE’’ because edge effects caused increases of both susceptance and conductance. (b)AC loss factor defined by Equation (1) (linear scale). (c) ECM current (right axis) and d.c. conductance (left axis). the ordinate uses a logarithmic scale. the d. c. conductance is the ratio of ECM current to the applied voltage.

Figure 2

Fig. 2The entire records of AC-ECM and ECM vs depth of ice (top axis) and, equivalently, age of ice (bottom axis). (a) AC loss factor (one of the right axes) corrected to values of –25˚C using an activation energy of 0.25 eV. This was converted to acidity (left axis) using Equation (2), and to high-frequency conductivity (one of right axes) using Equation (3). Symbols I–VI indicate the experimental conditions shown in Table 1. Data from ice deeper than 2390 m were rejected due to a technical problem. (b) ECM current corrected to values of –25˚Cusing an activation energy of 0.23 eV. (c) Acidity calculated from the AC loss factor is the same as in (a), but the density of data within a unit grid size of 103 years×0.2 μM is shown as an arbitrary gray scale.The blackest regions have the most data points for that particular 103 year period. This gray-scale image shows the mean tendency of the signal. the open squares are data points from pH measurement of the ice core. Five 50 cm long core segments were used. (d) ECM current as in (b) but plotted as a density plot with unit grid of 103 years×0.1 μA. the density-plot style is the same as in (c). (e) Oxygen isotope profile (Watanabe and others, 1999). the temperature scale in the right axis was calculated from a present-day relation between δ18O and mean annual surface temperature on the plateau of east Dronning Maud Land (Satow and others, 1999).

Figure 3

Fig. 3Plot of ECM current vs AC loss factor at –25˚C for three depth levels (Table1). Consecutive data are connected bygray lines to show depth trajectories of data points (lines connecting data at adjacent depths) at peaks in the AC loss factor. Contour lines are drawn for the densities of 80%, 60%, 40% and 20% of the maximum density.

Figure 4

Table 2.Multiple regression analysis between AC loss factor and major ions in the core section from 850 to 2250 m

Figure 5

Table 3.Regression coefficients of sulfate to explain AC loss factor for the six examined depth ranges

Figure 6

Fig. 4Decrease of the electrical signals with increasing depths. Data points are averaged values for every 50 m along the core.

Figure 7

Fig. 5Plot of acidity derived from the AC loss vs oxygen isotope record. Data points are shown in gray. Contour lines are drawn for every 10% of density, with 100% representing the maximum density in the graph. the tentative temperature scale in the top axis is the same as in Figure 2.