Hostname: page-component-74656f9884-npj9w Total loading time: 0 Render date: 2026-11-07T20:58:08.530Z Has data issue: false hasContentIssue false

Monitoring and characterization of particle contamination in the pulse compression chamber of the OMEGA EP laser system

Published online by Cambridge University Press:  20 April 2023

B. N. Hoffman
Affiliation:
Laboratory for Laser Energetics, University of Rochester, Rochester, New York, USA
N. Savidis
Affiliation:
Laboratory for Laser Energetics, University of Rochester, Rochester, New York, USA
S. G. Demos*
Affiliation:
Laboratory for Laser Energetics, University of Rochester, Rochester, New York, USA
*
Correspondence to: B. Hoffman, Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, New York 14623-1299, USA. Email: bhof@lle.rochester.edu

Abstract

The laser-damage performance of optics is known to be negatively affected by microscale particle contamination induced by the operational environment. This work investigates the properties of particles accumulating in various locations near critical optics inside the OMEGA EP grating compressor chamber during quarterly operational periods over a 2-year duration. The particles found were characterized using optical microscopy, scanning electron microscopy and energy dispersive X-ray spectroscopy. The analysis indicates significant concentrations of micrometer- to nanometer-scale particles inside the vacuum chamber, with higher values observed near the port leading to the OMEGA EP target chamber. The distribution of the chemical composition of these particles varies between collection periods. Although understanding of the mechanisms of particle generation and transport remains uncertain, the hypothesis is that this particle load represents a risk for contaminating the surfaces of high-value optics located inside the chamber, including the compression gratings and deformable mirrors, and therefore affecting their laser-damage resistance and overall operational lifetime.

Information

Type
Research Article
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (https://creativecommons.org/licenses/by/4.0), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2023. Published by Cambridge University Press in association with Chinese Laser Press
Figure 0

Figure 1 Simplified schematic depicting the laser beam path of the (a) upper compressor and (b) lower compressor in the OMEGA EP GCC. The blue circles indicate the optics where collection substrates were adjacently positioned. VW, input vacuum window; M, mirror; DM, deformable mirror; G, grating; GIS, grating inspection system; PM, periscope mirror; BC, beam combiner; BD, beam dump.

Figure 1

Figure 2 Particle density on the uncoated collection substrates measured with the 10× objective for each location inside the OMEGA EP GCC over the course of the study.

Figure 2

Figure 3 Particle diameter distribution histogram for each location for the FY22 Q2 operational period with samples imaged with the (a) 10× objective and (b) 50× objective. The histogram bin size for both magnifications is 0.25 μm.

Figure 3

Figure 4 Scanning electron microscope (SEM) images of stainless-steel particles that were generated offline via mechanical shaving with a metal file. The particles have rough, distinct surfaces and edges.

Figure 4

Figure 5 SEM images of stainless-steel particles that were generated offline via laser ablation with a 355-nm, 5-ns pulsed laser. Particles that were not droplets tended to have a foam-like texture, as shown in the inset.

Figure 5

Figure 6 SEM images of different stainless-steel particles collected in the GCC vacuum chamber.

Figure 6

Table 1 Composition distribution of particles characterized using energy dispersive X-ray analysis (EDS) for two operation periods, ‘FY21 Q4’ and ‘FY22 Q1’, and categorized as ‘total’, representing all identified particles found at different locations, and as ‘UC G2’, representing identified particles that were collected near the upper compressor G2.

Figure 7

Figure 7 SEM images of particles that are a conglomeration of smaller particles. (a1) SEM image of an aluminum particle with pieces of silicon attached on top. (a2) EDS map of elements for the particles in (a1). (b)–(e) Additional SEM image examples of particle conglomerations with elements identified.