Hostname: page-component-74656f9884-j7cmm Total loading time: 0 Render date: 2026-11-06T04:31:18.974Z Has data issue: false hasContentIssue false

Quantitative phase analysis of challenging samples using neutron powder diffraction. Sample #4 from the CPD QPA round robin revisited

Published online by Cambridge University Press:  29 April 2016

Pamela S. Whitfield*
Affiliation:
Oak Ridge National Lab, Spallation Neutron Source, PO Box 2008, MS-6475, Oak Ridge, Tennessee 37831
*
a) Author to whom correspondence should be addressed. Electronic mail: whitfieldps@ornl.gov

Abstract

Quantitative phase analysis (QPA) using neutron powder diffraction more often than not involves non-ambient studies where no sample preparation is possible. The larger samples and penetration of neutrons versus X-rays makes neutron diffraction less susceptible to inhomogeneity and large grain sizes, but most well-characterized QPA standard samples do not have these characteristics. Sample #4 from the International Union of Crystallography Commission on Powder Diffraction QPA round robin was one such sample. Data were collected using the POWGEN time-of-flight (TOF) neutron powder diffractometer and analysed together with historical data from the C2 diffractometer at Chalk River. The presence of magnetic reflections from Fe3O4 (magnetite) in the sample was an additional consideration, and given the frequency at which iron-containing and other magnetic compounds are present during in-operando studies their possible impact on the accuracy of QPA is of interest. Additionally, scattering from thermal diffuse scattering in the high-Q region (<0.6 Å) accessible with TOF data could impact QPA results during least-squares because of the extreme peak overlaps present in this region. Refinement of POWGEN data was largely insensitive to the modification of longer d-spacing reflections by magnetic contributions, but the constant-wavelength data were adversely impacted if the magnetic structure was not included. A robust refinement weighting was found to be effective in reducing quantification errors using the constant-wavelength neutron data both where intensities from magnetic reflections were ignored and included. Results from the TOF data were very sensitive to inadequate modelling of the high-Q (low d-spacing) background using simple polynomials.

Information

Type
Technical Articles
Copyright
Copyright © International Centre for Diffraction Data 2016 
Figure 0

Table I. Aggregated mean results from the CPD round robin for the different types of source.

Figure 1

Table II. Refined QPA phase fractions, maximum absolute error, and maximum relative bias obtained from POWGEN and C2 data.

Figure 2

Figure 1. (Color online) Difference plot for the POWGEN refinement with a Q-dependent thermal diffuse background where the magnetic structure was (a) not modelled and (b) modelled. The cumulative χ2 plot is the blue line.

Figure 3

Figure 2. (Color online) Fit to the C2 data where the magnetic structure was (a) not modelled and (b) modelled. The cumulative χ2 plot is the blue line.

Figure 4

Figure 3. (Color online) Fit to the C2 data where the magnetic structure was not modelled and a robust refinement weighting applied. The cumulative χ2 plot is the blue line.

Figure 5

Table III. Comparison of selected POWGEN and C2 results with the participants in the CPD round robin who submitted neutron data for sample #4.

Supplementary material: File

Whitfield supplementary material

Whitfield supplementary material 1

Download Whitfield supplementary material(File)
File 475.8 KB
Supplementary material: File

Whitfield supplementary material

Tables SI-SIII

Download Whitfield supplementary material(File)
File 24.6 KB