Hostname: page-component-7b7567c8c-7pwfn Total loading time: 0 Render date: 2026-11-16T03:18:56.932Z Has data issue: false hasContentIssue false

Size distribution of a drop undergoing breakup at moderate Weber numbers

Published online by Cambridge University Press:  24 March 2023

Someshwar Sanjay Ade
Affiliation:
Center for Interdisciplinary Program, Indian Institute of Technology Hyderabad, Kandi, 502 284 Sangareddy, Telangana, India
Lakshmana Dora Chandrala*
Affiliation:
Department of Mechanical and Aerospace Engineering, Indian Institute of Technology Hyderabad, Kandi, 502 284 Sangareddy, Telangana, India
Kirti Chandra Sahu*
Affiliation:
Department of Chemical Engineering, Indian Institute of Technology Hyderabad, Kandi, 502 284 Sangareddy, Telangana, India
*
†Email addresses for correspondence: lchandrala@mae.iith.ac.in, ksahu@che.iith.ac.in
†Email addresses for correspondence: lchandrala@mae.iith.ac.in, ksahu@che.iith.ac.in

Abstract

The size distribution of child droplets resulting from a dual-bag fragmentation of a water drop is investigated using shadowgraphy and digital in-line holography techniques. It is observed that parent drop fragmentation contributes to the atomisation of tiny child droplets, whereas core drop disintegration predominantly results in larger fragments. Despite the complexity associated with dual-bag fragmentation, we demonstrate that it exhibits a bi-modal size distribution. In contrast, the single-bag breakup undergoes a tri-modal size distribution. We employ the analytical model developed by Jackiw & Ashgriz (J. Fluid Mech., vol. 940, 2022, A17) for dual-bag fragmentation that convincingly predicts the experimentally observed droplet volume probability density. We also estimate the temporal evolution of child droplet production in order to quantitatively illustrate the decomposition into initial and core breakups. Furthermore, we confirm that the analytical model adequately predicts the droplet size distribution for a range of Weber numbers.

Information

Type
JFM Papers
Copyright
© Indian Institute of Technology Hyderabad, India, 2023. Published by Cambridge University Press
Figure 0

Figure 1.Schematic diagram of the experimental set-up (top view).

Figure 1

Figure 2.Demonstration of different steps of the in-line holography. (a) Typical shadowgraphy image of the satellite droplets during the fragmentation process. (b,c) Recorded and pre-processed holograms. (d,e) The reconstructed images at two different planes.

Figure 2

Figure 3.Temporal evolution of the fragmentation process (from shadowgraphy) and DSD (the droplet counts $N$ versus the droplet diameter $d$) for (a) ${{We}} = 12.6$ and (b) ${{We}} = 34.8$. The dimensionless time and droplet position in the flow direction $(y/D_{n})$ are mentioned in each panel. Here, $\tau =0$ represents the onset of breakup. The droplet breakup phenomena for ${{We}} = 12.6$ and 34.8 are provided as supplementary movies 2 and 3, respectively. The corresponding time-series focused holograms are included as supplementary movies 4 and 5, respectively.

Figure 3

Figure 4.Temporal variation of the normalised (a) number mean diameter $(d_{10}/d_0)$ and (b) Sauter mean diameter $(d_{32}/d_0)$ for ${{We}}=12.6$ and 34.8. The error bar represents the standard deviation obtained using three repetitions.

Figure 4

Figure 5.Comparison of the theoretically predicted droplet characteristic breakup sizes with experimental data: (a–c) ${{We}} = 12.6$ at $\tau =0.84$ and (d–f) ${{We}}=34.8$ at $\tau =1.06$. Here, the black and red lines represent the characteristic sizes of the parent and core drops, respectively. The insets in panels (a,c) show the enlarged views for small-size child droplets with the axis for $d/d_0$ in $\log$ scale.

Figure 5

Figure 6.Comparison of the multi-modal distribution obtained from the experiments with the analytical predictions for (a) ${{We}} = 12.6$ at $\tau =0.84$ (single-bag breakup) and (b) ${{We}} = 34.8$ at $\tau =1.06$ (dual-bag breakup). The solid line represents the size distribution due to the sum of all modes (overall size distribution). Panels (c,d) present the results of panels (a,b) in $\log$ scale for $d/d_0$ axis.

Figure 6

Figure 7.Mode decomposition for single-bag breakup at $We=12.6$. (a–c) Shadowgraphy images at three instants corresponding to the maximum bag inflation $(\tau =0)$, rupture of bag $(\tau =0.42)$ and fragmenting of the rim and node $(\tau =0.84)$, respectively. The corresponding size distributions of child droplets at $\tau =0.42$ and 0.84 are shown in panels (d,e), respectively.

Figure 7

Figure 8.Comparison of experimental data with the theoretically predicted characteristic breakup sizes at (a) $\tau =0.42$, and (b,c) $\tau =0.84$ for ${{We}} = 12.6$ (single-bag breakup). The panels (b,c) correspond to the rim and node fragmentations, respectively.

Figure 8

Figure 9.Mode decomposition for the dual-bag breakup at $We=34.8$. Panels (a–d) depict shadowgraphy images at four instants corresponding to the maximum inflation of the parent bag $(\tau =0)$, rupture of parent bag $(\tau =0.3)$, fragmenting of core bag $(\tau =0.61)$ and fragmenting of rim + nodes $(\tau =1.06)$, respectively. The corresponding size distributions of child droplets at $\tau =0.3$, 0.61 and 1.06 are shown in panels (e,f,g), respectively.

Figure 9

Figure 10.Comparison of experimental data with the theoretically predicted characteristic breakup sizes at (a) $\tau =0.30$, (b) $\tau =0.61$ and (c,d) $\tau =1.06$ for ${{We}} = 34.8$ (dual-bag breakup). The panels (c,d) correspond to the rim and node fragmentations, respectively.

Figure 10

Figure 11.Temporal evolution of a water droplet ($d_{0}=4.3$ mm) undergoing multi-bag fragmentation process (${{We}} = 40.15$). Panels (a–e) depict shadowgraphy images at five instants corresponding to the maximum inflation of parent bag $(\tau =0)$, rupture of parent bag $(\tau =0.10)$, fragmenting of second bag $(\tau =0.31)$, inflation of third bag $(\tau =0.62)$ and fragmentation of rim and nodes $(\tau =0.56)$, respectively. The dimensionless time $(\tau )$ and droplet position in the flow direction $(y/D_{n})$ are mentioned in each panel. The corresponding size distributions of the child droplets at $\tau =0.10$, 0.31, 0.62 and 1.06 are shown in panels (f–i), respectively.

Figure 11

Figure 12.Comparison of the multi-modal size distribution obtained from the experiments with the analytical predictions for ${{We}} = 40.15$ at $\tau =1.56$.

Figure 12

Figure 13.Temporal variation of the normalised (a) number mean diameter $(d_{10}/d_0)$ and (b) Sauter mean diameter $(d_{32}/d_0)$ for ${{We}}=40.15$. The error-bar represents the standard deviation obtained using three repetitions.

Figure 13

Figure 14.Comparison of the analytical model with the experimental data for a water drop of initial diameter $d_{0}= 4.3$ mm and ${{We}} = 30.0$. This exhibits a dual-bag breakup.

Figure 14

Figure 15.Comparison of the analytical model with the experimental data taken from Guildenbecher et al. (2017) for an ethanol drop of initial diameter $d_{0}=2.7$ mm at (a) ${{We}}=13.8$ (single-bag breakup) and (b) ${{We}}=55.3$ (sheet-thinning breakup).

Ade et al. Supplementary Movie 1

Transitional breakup of a water droplet at We = 11.4.

Download Ade et al. Supplementary Movie 1(Video)
Video 1.7 MB

Ade et al. Supplementary Movie 2

Single-bag breakup of a water droplet at We = 12.6.

Download Ade et al. Supplementary Movie 2(Video)
Video 1.4 MB

Ade et al. Supplementary Movie 3

Dual-bag breakup of a water droplet at We = 34.8.

Download Ade et al. Supplementary Movie 3(Video)
Video 1.1 MB

Ade et al. Supplementary Movie 4

Time-series focused holograms at We = 12.6.

Download Ade et al. Supplementary Movie 4(Video)
Video 3.1 MB

Ade et al. Supplementary Movie 5

Time-series focused holograms at We = 34.8.

Download Ade et al. Supplementary Movie 5(Video)
Video 3.1 MB