Hostname: page-component-74656f9884-npj9w Total loading time: 0 Render date: 2026-11-07T22:05:09.297Z Has data issue: false hasContentIssue false

Unravelling Quasi-Continuous 14C Profiles by Laser Ablation AMS

Published online by Cambridge University Press:  09 December 2019

C Yeman*
Affiliation:
Laboratory of Ion Beam Physics, ETH Zurich, Otto-Stern-Weg 5, HPK, 8093 Zurich, Switzerland
M Christl
Affiliation:
Laboratory of Ion Beam Physics, ETH Zurich, Otto-Stern-Weg 5, HPK, 8093 Zurich, Switzerland
B Hattendorf
Affiliation:
Laboratory of Inorganic Chemistry, ETH Zurich, Vladimir-Prelog-Weg 1-5/10, HCI, 8093 Zurich, Switzerland
L Wacker
Affiliation:
Laboratory of Ion Beam Physics, ETH Zurich, Otto-Stern-Weg 5, HPK, 8093 Zurich, Switzerland
C Welte
Affiliation:
Laboratory of Ion Beam Physics, ETH Zurich, Otto-Stern-Weg 5, HPK, 8093 Zurich, Switzerland
N Brehm
Affiliation:
Laboratory of Ion Beam Physics, ETH Zurich, Otto-Stern-Weg 5, HPK, 8093 Zurich, Switzerland
H-A Synal
Affiliation:
Laboratory of Ion Beam Physics, ETH Zurich, Otto-Stern-Weg 5, HPK, 8093 Zurich, Switzerland
*
*Corresponding author. Email: yemanc@phys.ethz.ch.
Rights & Permissions [Opens in a new window]

Abstract

Laser ablation (LA) accelerator mass spectrometry (AMS) is a novel method for rapid online radiocarbon (14C) analysis of carbonates. The quasi-continuous 14C profiles obtained with this technique demand a customized data evaluation protocol to relate the acquired 14C data to the analyzed sample. We take into account the mixing effects due to the minimal counting (integration) time of the AMS, the finite width of the laser beam and the gas washout of the ablation volume. Thereby we mathematically describe our LA setup with a system function that acts on the produced CO/CO2 (COX) from the sample resulting in a mixing of the 14C profiles obtained by AMS analysis. Furthermore, we analyze the long-term target memory effect in the gas ion source and establish a routine for correction. The correction routine is tested with a stalagmite comprising a growth stop that is analyzed at different scanning velocities indicating that only the slow scanning velocity can provide the necessary resolution to determine the width of the growth stop of 365 μm.

Information

Type
Research Article
Copyright
© 2019 by the Arizona Board of Regents on behalf of the University of Arizona
Figure 0

Figure 1 Schematic view of the LA-AMS system. CO and CO2 are produced by LA in the ablation volume (left box) and then transported via a glass capillary to the ion source of the AMS (right box) passing two consecutive filters. A valve allows switching between the cell head and a He line for flushing the capillary to the ion source. The mixing effects are marked with red numbers: 1—laser-beam width, 2—washout, 3—target memory. (Please see electronic version for color figures).

Figure 1

Table 1 Key factors for carbon production.

Figure 2

Figure 2 A—12C current of a typical LA AMS measurement with rise of the current when the laser is turned on and drop in the current when the laser is turned off. B—zoom into 5 cycles to show schematically the movement of the laser-beam spot on the sample. The black rectangles indicate the area of the overlap which is the size of the laser-beam spot. The colors imply that material from this area contributes to two cycles. C—depth profile on the sample; colors show contribution to the respective cycles.

Figure 3

Figure 3 Functions describing A—minimum counting time, B—overlap due to laser-beam width, C—cell washout and short-term target memory, and D—system function. The convolution is implicated by “*” following Eq. (2).

Figure 4

Figure 4 A—12C ion current on the high energy side from four different targets at same carbon flow from GIS into the ion source. Carbon flow was stopped after counting times of 20, 40, 60, 80 cycles; B—zoom into the drop of 12C current of the black curve in A. The decline follows two exponential function with long and short time constant.

Figure 5

Figure 5 A—rectangular function (blue) measured with LA AMS (black). Parameters are fitted so after target memory correction the measured data yield the sample value (red). B—build-up of target memory, C—evolution of F14C on target.

Figure 6

Figure 6 In pink the convolution of rectangular function (blue) with the system function and fitted to the long-term target memory corrected data (black).

Figure 7

Figure 7 Growth stop in a stalagmite measured with different velocities and scanning directions in black, in blue the idealized F14C of the sample, and in pink its convolution with the system function. The grey area in B is the equivalent distance covered in A.

Supplementary material: File

Yeman et al. supplementary material

Yeman et al. supplementary material

Download Yeman et al. supplementary material(File)
File 241.8 KB