Transcatheter pulmonary valve insertion, expanded use and future directions*

Published online by Cambridge University Press:  09 January 2014

Jeremy M. Ringewald*
Affiliation:
Division of Pediatric Cardiology, The Congenital Heart Institute of Florida (CHIF), St. Joseph's Children's Hospital of Tampa, Pediatric Cardiology Associates/Pediatrix Medical Group, Saint Petersburg, Florida, United States of America
Elsa J. Suh
Affiliation:
Division of Pediatric Cardiology, The Congenital Heart Institute of Florida (CHIF), St. Joseph's Children's Hospital of Tampa, Pediatric Cardiology Associates/Pediatrix Medical Group, Saint Petersburg, Florida, United States of America
*
Correspondence to: Jeremy M. Ringewald, MD, Pediatric Cardiology Associates, 3003 W. Dr. MLK Jr. BLVD, Tampa, FL 33607. Tel: 8135548701; Fax: 8138700100; Email: tampakidhrtdoc@gmail.com
Rights & Permissions [Opens in a new window]

Abstract

Transcatheter pulmonary valve replacement with the Melody® valve is an accepted alternative to surgical replacement of the pulmonary valve for some patients and therefore a complementary strategy in the long-term management of several groups of patients with congenital heart disease. It allows at least extending the time between sternotomies and possibly improving late outcomes. With a combined surgical and percutaneous approach, late morbidity for some of these patients will likely be diminished. This manuscript will review the current expanded applications for this technology, demonstrate several examples of its use and discuss future directions for this evolving equipment.

Information

Type
Original Article
Copyright
Copyright © Cambridge University Press 2013 
Figure 0

Figure 1 (a) A lateral view of the conduit before intervention; note the marked calcification and narrowing of the valve and severe regurgitation. (b) Marked enlargement of the conduit with stenting. (c) The competent new valve.

Figure 1

Figure 2 (a) A lateral view of the conduit before intervention; note the complete lack of calcification but significant narrowing at the prior valve annulus. (b) Marked compliance of the conduit with balloon sizing. (c) The competent new valve.

Figure 2

Figure 3 (a) A lateral view of the dysfunctional ePTFE bivalve during systole; note the marked calcification and thickening of the posterior leaflet stuck in a partially open position. (b) Balloon sizing with a slight waist, at the valve, corresponding to the calcified posterior leaflet. (c) The competent new valve.