Closure of small fenestrations without optimal rims with a PDA coil far from primary atrial septal defects: a new approach

Published online by Cambridge University Press:  08 October 2024

Sylvia K. Sánchez González*
Affiliation:
National Medical Center “20 of November”, Department of Congenital and Structural Intervention, México City, México
José L. Colín Ortiz
Affiliation:
National Institute of Paediatrics, Department of Paediatric Cardiology, México City, México
Alejandro Flores Arizmendi
Affiliation:
National Medical Center “20 of November”, Department of Congenital and Structural Intervention, México City, México
Alfredo Bobadilla Aguirre
Affiliation:
National Institute of Paediatrics, Department of Paediatric Cardiology, México City, México
Carlos A. Corona Villalobos
Affiliation:
National Institute of Paediatrics, Department of Paediatric Cardiology, México City, México
*
Corresponding author: Sylvia K. Sánchez González; Email: dra.sylvia.sanchez@outlook.com
Rights & Permissions [Opens in a new window]

Abstract

An ostium secundum atrial septal defect (ASD) is a CHD that can be treated percutaneously since 1974, mostly cases with only one main defect. In cases with fenestrations close to the main defect, a single occluder can be used for treatment because the discs extend beyond the waist of the device. In some cases where the defects are far from each other, they may require either more than one device or surgical closure. We present two patients in whom we observed fenestrations far from the primary defect. Initially, the main ASDs were closed with an ASD occluder, and then the fenestrations were closed with a patent ductus arteriosus (PDA) coil, resulting in complete closure of both defects. This shows that closing small fenestrations that are far away from the primary interatrial defect without rims and using other devices instead, such as a PDA coil, is feasible and can avoid the need for an open-heart surgical procedure; moreover, it is important to note that leaving these fenestrations open can have the same physiology as a patent foramen oval.

Information

Type
Original Article
Copyright
© The Author(s), 2024. Published by Cambridge University Press
Figure 0

Figure 1. Intracardiac echocardiogram. (a) Primary OS ASD 9 x 12 mm. (b) Distal fenestration 1.2 mm L–R shunt.

Figure 1

Figure 2. (a) Closure of the primary defect with a 15-mm Figulla flex II Occluder. (b) Deployment of PDA coil device. (c) After confirmation, PDA coil is released.

Figure 2

Figure 3. (a) Right atrium angiography showing the coil and ASD device in adequate positions. (b/c) Follow-up chest X-ray showing both devices in good positions.

Figure 3

Figure 4. (a) Closure of the primary defect with a 15-mm Figulla flex II occluder. (b) Deployment of the PDA coil device. (c) After the PDA coil was released, no residual shunt was observed.

Figure 4

Figure 5. (a/b) Right atrium fluoroscopy showing the coil and ASD device in adequate positions. (c) Follow-up chest X-ray showing both devices in good positions.