Hostname: page-component-74656f9884-j7cmm Total loading time: 0 Render date: 2026-11-05T21:25:00.168Z Has data issue: false hasContentIssue false

UV Photochemical Oxidation and Extraction of Marine Dissolved Organic Carbon at UC Irvine: Status, Surprises, and Methodological Recommendations

Published online by Cambridge University Press:  15 April 2019

Brett D Walker*
Affiliation:
Department of Earth and Environmental Sciences, University of Ottawa, Ottawa, ON K1N 6N5, Canada Department of Earth System Science, University of California Irvine, CA 92697-3100, USA
Steven R Beaupré
Affiliation:
School of Marine and Atmospheric Sciences, Stony Brook University, Stony Brook, NY 11794-5000, USA
Sheila Griffin
Affiliation:
Department of Earth System Science, University of California Irvine, CA 92697-3100, USA
Ellen R M Druffel
Affiliation:
Department of Earth System Science, University of California Irvine, CA 92697-3100, USA
*
*Corresponding author. Email: brett.walker@uottawa.ca.
Rights & Permissions [Opens in a new window]

Abstract

The first ultraviolet photochemical oxidation (UVox) extraction method for marine dissolved organic carbon (DOC) as CO2 gas was established by Armstrong and co-workers in 1966. Subsequent refinement of the UVox technique has co-evolved with the need for high-precision isotopic (Δ14C, δ13C) analysis and smaller sample size requirements for accelerator mass spectrometry radiocarbon (AMS 14C) measurements. The UVox line at UC Irvine was established in 2004 and the system reaction kinetics and efficiency for isolating seawater DOC rigorously tested for quantitative isolation of ∼1 mg C for AMS 14C measurements. Since then, improvements have been made to sampling, storage, and UVox methods to increase overall efficiency. We discuss our progress, and key UVox system parameters for optimizing precision, accuracy, and efficiency, including (1) ocean to reactor: filtration, storage and preparation of DOC samples, (2) cryogenic trap design, efficiency and quantification of CO2 break through, and (3) use of isotopic standards, blanks and small sample graphitization techniques for the correction of DOC concentrations and Fm values with propagated uncertainties. New DOC UVox systems are in use at many institutions. However, rigorous assessment of quantitative UVox DOC yields and blank contributions, DOC concentrations and carbon isotopic values need to be made. We highlight the need for a community-wide inter-comparison study.

Information

Type
Conference Paper
Copyright
© 2019 by the Arizona Board of Regents on behalf of the University of Arizona 
Figure 0

Figure 1 Dissolution of crystals from thawed seawater samples. Pictured is a time series of a thawed, acidified sample with abundant crystals. The sample was vigorously shaken every 1 min to achieve crystal re-dissolution. (A) 1.0 mL of phosphoric acid is added to the 1-L amber Boston round sample bottle, a flashlight behind the bottle helps illustrate the mound of crystals. (B) Half of the original crystals remain after 6 min of repeated shaking. (C) Almost 100% of crystals have re-dissolved by 20 min of shaking.

Figure 1

Figure 2 Example of monitoring CO2 gas leaving the DOC UVox line over an experiment. At the beginning of the day, DIC and residual CO2 in the DOC line is removed via acidification of the sample and sparging with UHP He (DIC Sparge). When all residual CO2 is removed, the He flow is stopped, the line isolated from atmosphere and UVox started. Throughout UVox, the system vent tubing slowly “bleeds up” to lab air. This does not affect the DOC sample, because it is isolated. After 4 hr, the UVox is stopped and He gas is used to sparge all resultant CO2 for isolation in the Horibe trap (DOC Sparge). In this example, a flow rate of 200 mL min–1 was used. Several minutes later, we see sample C breaking through the Horibe trap and leaving the system (0–10 ppm). BT lasts between 45 and 70 min, depending on [DOC] and flow rate.

Figure 2

Figure 3 Mass and C isotopic effects of sample breakthrough (BT) at differing OX-I [DOC] and flow rates. (a) relationship between mass of BT as CO2 (µgC) at two He flow rates and three [DOC] values. (b) DOC OX-I Fm values, both uncorrected and corrected, showing no effect of sample BT C on corrected 14C measurements. (c) uncorrected DOC OX-I δ13C values show no isotopic fractionation with sample C BT. In plots B and C, the green line represents the consensus Fm and δ13C value of OX-I. (Please see electronic version for color figures.)

Figure 3

Figure 4 Hybrid stainless steel cryogenic trap design and C BT results. (A) Side-view of the hybrid 0.25 in and 0.125 in OD stainless cryotrap next to a 15 cm ruler. (B) View of hybrid stainless trap in use. The bottom third of the cryotrap is placed in liquid nitrogen (LN2) allowing CO2 gas to heat up and re-freeze on each pass around the trap. (C) LiCOR trace of CO2 (ppm; black line) and rate of CO2 loss (µgC min–1; green line) exiting the system as CO2 (400 ppm) in He reference gas is flowed at 150 mL min–1. (D) LiCOR trace of CO2 (ppm; black line) and rate of CO2 loss (µgC min–1; green line) exiting the system as CO2 (400 ppm) in He reference gas is flowed at 50 mL min–1. Plots C and D, the blue line represents the baseline CO2 ppm value achieved with pure UHP He (no CO2) prior to the beginning of the experiment. Black arrows indicate the moment liquid nitrogen (LN2) was added to the trap, at which point the resultant LiCOR CO2 ppm values decrease. Grey shaded regions show the 10 min integration periods, from which equilibrated trap BT CO2 ppm values were determined.

Figure 4

Figure 5 Conceptual diagram of carbon mass contributions and aqueous volumes for DOC samples, standards, diluent and line blanks. Various amounts of extraneous C are added for each sample type and diluent volume used. A ubiquitous, volume-less extraneous carbon “line blank” is inherent to all DOC UVox measurements. A seawater sample prepared using the dilution method also contains 100–200 mL of low carbon Milli-Q water as a diluent. A DOC isotopic standard (0.2–0.8 mgC) is accurately weighed and quantitatively transferred to the reactor with diluent. Standards contain far more MQ diluent by both mass (10–15 µgC) and aqueous volume (1000 mL) than samples. A diluent blank (MQ) is comprised only of MQ carbon and the line blank.

Figure 5

Figure 6 Fraction modern (Fm) values of DOC isotopic standards at UC Irvine. (A) DOC OX-I Fm values (n = 109) vs. date of UVox, (B) DOC OX-I Fm values vs. size, (C) DOC Glycine Fm values vs. date of UVox, (D) DOC Glycine Fm values (n = 67) vs. size. In all plots, open and closed symbols represent uncorrected and blank corrected Fm data, respectively. Green lines indicate OX-I and Glycine consensus Fm values. Error bars represent 1-sigma propagated errors of blank corrected Fm values.

Figure 6

Figure 7 Bland-Altman difference plot illustrating direct and indirect blank corrected DOC sample Fm data. Green line indicates no difference between the two correction methods. The dashed blue line represents the least squares linear regression of the method difference vs. average Fm value of the two methods. Data are from n = 34 DOC sample “unknowns” measured at UC Irvine in March 2018.

Figure 7

Figure 8 Stable isotopic (δ13C) permil values of DOC isotopic standards at UC Irvine. (A) DOC OX-I δ13C values vs. date of UVox, (B) DOC OX-I δ13C values vs. samples size, (C) DOC Glycine δ13C value vs. date of UVox, (D) DOC Glycine δ13C value vs. sample size. In all plots, open symbols represent uncorrected δ13C values. Green lines indicate consensus δ13C values for OX-I (IAEA reported value) and Glycine (determined at UCI by routine EA-IRMS and closed tube combustion measurements). Error bars represent assigned ±0.2‰ errors of UVox δ13C values.