Hostname: page-component-74656f9884-c52kr Total loading time: 0 Render date: 2026-11-08T22:03:56.103Z Has data issue: false hasContentIssue false

Subnanosecond magnetization dynamics driven by strain waves

Published online by Cambridge University Press:  09 November 2018

Michael Foerster
Affiliation:
ALBA Synchrotron, Spain; mfoerster@cells.es
Lucia Aballe
Affiliation:
ALBA Synchrotron, Spain; laballe@cells.es
Joan Manel Hernàndez
Affiliation:
Department of Condensed Matter Physics, University of Barcelona, Spain; jm_hernandez@ub.edu
Ferran Macià
Affiliation:
Institut de Ciència de Materials de Barcelona (ICMAB-CSIC), Spain; fmacia@icmab.es

Abstract

The magnetic properties of a magnetic material can be modified by elastic deformation—termed the magnetoelastic effect. This effect is considered an alternative approach to magnetic fields for the low-power control of magnetization states of nanostructures since it avoids charge currents that create heat dissipation. This article describes the effects of dynamic strain accompanying a surface acoustic wave on magnetic nano-elements. We use a technique based on stroboscopic x-ray microscopy to simultaneously image the evolution of both strain and magnetization at the nanometer length and picosecond time scales. The study shows that there is a delayed response of the magnetization to dynamic strain, adjustable by the magnetic properties of the material. The presented analysis provides insights into dynamic magnetoelastic coupling in nanostructures with implications for the design of strain-controlled nanodevices.

Information

Type
Materials for Strain-Mediated Magnetoelectric Systems
Copyright
Copyright © Materials Research Society 2018 
Figure 0

Figure 1. Schematic plot of the experimental setup. X-rays (blue) with different circular polarization illuminate the sample with a repetition rate of f0 ∼ 500 MHz (20 ps pulse length). A radio-frequency (RF) electric signal is sent to the interdigital transducer (IDT, [yellow]) having the same frequency as the synchrotron repetition rate. The IDT generates a piezoelectric surface acoustic wave (SAW) that propagates through the LiNbO3 substrate (gray) and interacts with the magnetic nanostructures (red) deposited on the acoustic path. The phase-resolved variation of the piezoelectric voltage at the surface sample is probed with the photoemission electron microscope (PEEM) (upper left image), as well as the magnetic contrast (upper right image) along the x-ray propagation direction arising from the x-ray magnetic circular dichroism (XMCD) effect.

Figure 1

Figure 2. X-ray photoemission electron microscope images of a surface acoustic wave (SAW) at sample bias of (a) –3 V and (b) +0.5 V. The photon energy 848 eV, the total exposure time (10 s), and the size ≈ 30 × 23 μm2 are the same for both. The SAWs produce a contrast in the images because of the piezoelectric voltage associated with the wave. In the lower left and upper right corner of the images, the same alignment markers are visible as dark squares. (c) Local photoelectron bias voltage scans for the centers of the different stripes. The vertical lines mark the conditions at which the images in (a–b) were recorded. The maximum shift between local spectra shown in (c) allows for a quantification of the strain associated with the SAW. Green and blue rectangles indicate the regions of the sample where the local spectra shown in (c) were extracted.17

Figure 2

Figure 3. Simultaneous images of piezoelectric voltage and magnetization. (a–b) Photoemission electron microscope shows the piezoelectric voltage. Dashed blue lines illustrate the strain wave. (c–d) X-ray magnetic circular dichroism–photoemission electron microscope images show the magnetic configuration. Images of 2 × 2 µm2 Ni squares and are taken at opposite phases of the surface acoustic wave (SAW). The images correspond to maximum and minimum magnetic anisotropy values at 30° and 210°, respectively. The simple comparison with (a) and (b) where the square is not centered in white/black zone already permits visualizing the delay. Solid blue lines guide the eye to the different domains. (e–f) Schematic plots of the effect of SAW on Ni squares for maximal values of strain associated with the SAW. White and black arrows indicate the direction of magnetization. (g) Analysis of the domain configuration from multiple Ni squares as a function of the phase with respect to the SAW. The combined area of black (B) and white (W) domains (amount of magnetization along the x-ray incidence direction) as a fraction of the total square is shown. The best fit to the data with a sinusoidal function is plotted in red. A phase delay of 48° with respect to the strain wave is obtained. A schematic strain wave (without any delay) is plotted in gray in order to highlight the phase difference of the magnetic response. The green dashed horizontal line shows the averaged value without strain, which indicates some residual Ni anisotropy from the deposition process. Note: τ, phase delay.17

Figure 3

Figure 4. Micromagnetic modeling of the magnetic response in Ni squares caused by a surface acoustic wave (SAW). Amplitude (upper panel) and phase (lower panels) of the magnetic response of a system of 2 × 2 μm2 nickel square to an oscillating spatially varying anisotropy as a function of the excitation frequency. Two configurations are shown. (a) Squares are aligned with SAW and (b) squares are tilted 45° with respect to the SAW propagation direction (red arrow). Black and white arrows indicate the magnetization direction of the domains. The same quantities analyzed for the experimental data are plotted in (a) the variation (in %) of the fraction area of black (B) and white (W) domains and in (b), the variation (in %) of the normalized difference between the x-ray magnetic circular dichroism gray intensities between the left and right gray domains, labeled G1 and G2. Different resonances are found, corresponding to the gyration of the central vortex, the motion of domain walls (only in the aligned configuration), and the magnetization rotation within the domains (stronger in the tilted configuration). Dashed lines (in black) mark the frequency f = 500 MHz and the corresponding delay obtained in the phase for both configurations.17