Hostname: page-component-74656f9884-2dmjx Total loading time: 0 Render date: 2026-11-07T08:45:33.588Z Has data issue: false hasContentIssue false

Harbour porpoise (Phocoena phocoena) static acoustic monitoring: laboratory detection thresholds of T-PODs are reflected in field sensitivity

Published online by Cambridge University Press:  17 March 2008

Line A. Kyhn*
Affiliation:
National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde, Denmark Aarhus University, Department of Zoophysiology, C.F. Møllers Allé Building 1131, DK-8000 Aarhus, Denmark
Jakob Tougaard
Affiliation:
National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde, Denmark
Jonas Teilmann
Affiliation:
National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde, Denmark
Magnus Wahlberg
Affiliation:
Aarhus University, Department of Zoophysiology, C.F. Møllers Allé Building 1131, DK-8000 Aarhus, Denmark
Poul B. Jørgensen
Affiliation:
National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde, Denmark
Nikolaj I. Bech
Affiliation:
National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde, Denmark
*
Correspondence should be addressed to: Line A. KyhnNational Environmental Research InstituteFrederiksborgvej 399 DK-4000 RoskildeDenmark email: lky@dmu.dk
Rights & Permissions [Opens in a new window]

Abstract

The T-POD (Timing POrpoise Detector) is a self-contained acoustic data logger used for detecting and monitoring the presence of echolocation clicks of small cetaceans. It has become a standard tool in environmental impact assessments and monitoring programmes. Yet, little is known about the variability in sensitivity and detection range of T-PODs. In this study the field performance of ten v3 T-PODs was compared to detection thresholds measured in a tank. The T-POD thresholds ranged from 123 to 132 dB re 1μPa (pp). The detection thresholds of the ten individual T-PODs were different and the differences increased over time. The more sensitive a T-POD was in the laboratory (i.e. the lower the threshold) the more clicks were recorded by it in the field. Threshold correlated differently to the five analysed T-POD parameters (encounters, encounter duration, waiting time, porpoise positive minutes, clicks per porpoise positive minute). This study demonstrates that individual threshold calibrations of T-PODs are necessary to obtain comparable results when monitoring odontocetes with this tool. Regression equations for relationships between T-POD detection thresholds and study parameters obtained during field trials may allow comparisons of T-PODs with different detection thresholds.

Information

Type
Research Article
Copyright
Copyright © Marine Biological Association of the United Kingdom 2008
Figure 0

Fig. 1. Mean Timing POrpoise Detector (T-POD) detection thresholds measured in an experimental set-up at four angles of incidence around the hydrophone before field deployment in this study (X-axis) and after seven months deployment (Y-axis) in a subsequent study. Stars mark three T-PODs that were lost before second calibration. The regression line signifies the shift in mean detection threshold per T-POD between the two calibrations.

Figure 1

Fig. 2. The five porpoise indicators recorded in the field in relation to detection threshold for each Timing POrpoise Detector (T-POD). (A) Waiting time; (B) encounter duration; (C) clicks per porpoise positive minute (CPPM); (D) porpoise positive minutes (PPM); and (E) number of encounters as a function of T-POD detection threshold measured in a tank. Number of encounters and porpoise positive minutes are totals per T-POD for the study period, whereas encounter duration, waiting time and clicks per porpoise positive minutes are means per T-POD. The standard error of the mean (SEM) is largely due to the natural clumped occurrence of porpoises around the T-PODs at the study site. All parameters are built on clicks in the category ‘Cet All’ (see text).

Figure 2

Fig. 3. Number of clicks detected as a function of the Timing POrpoise Detector (T-POD) detection threshold. Stars are field values and circles are modelled values. The model assumed a fixed porpoise source level of 205 dB re μPa (pp), and a beam pattern modelled on the properties of a circular piston (Au, 1993). The slopes are statistically similar (see text for details). Differences in intercept on the Y-axis between the two functions are due to the lower number of clicks put into the model as compared to the field trials.