Hostname: page-component-74656f9884-npj9w Total loading time: 0 Render date: 2026-11-08T18:16:25.794Z Has data issue: false hasContentIssue false

Particle-in-cell simulations of current loss in magnetically insulated transmission line with inductive helical support

Published online by Cambridge University Press:  15 August 2019

Wei Luo
Affiliation:
Key Laboratory for Physical Electronics and Devices of the Ministry of Education, School of Electronic and Information Engineering, Xi'an Jiaotong University, Xi'an 710049, China
Yongdong Li*
Affiliation:
Key Laboratory for Physical Electronics and Devices of the Ministry of Education, School of Electronic and Information Engineering, Xi'an Jiaotong University, Xi'an 710049, China
Hongguang Wang
Affiliation:
Key Laboratory for Physical Electronics and Devices of the Ministry of Education, School of Electronic and Information Engineering, Xi'an Jiaotong University, Xi'an 710049, China
Fan Guo
Affiliation:
Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China
Wenkang Zou
Affiliation:
Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China
Pengfei Zhang
Affiliation:
State Key Laboratory of Intense Pulse Radiation of Simulation and Effect, NINT, Xi'an 710024, China
Lei Zhang
Affiliation:
Key Laboratory for Physical Electronics and Devices of the Ministry of Education, School of Electronic and Information Engineering, Xi'an Jiaotong University, Xi'an 710049, China
Yu Gu
Affiliation:
Key Laboratory for Physical Electronics and Devices of the Ministry of Education, School of Electronic and Information Engineering, Xi'an Jiaotong University, Xi'an 710049, China
Jianwei Zhang
Affiliation:
Key Laboratory for Physical Electronics and Devices of the Ministry of Education, School of Electronic and Information Engineering, Xi'an Jiaotong University, Xi'an 710049, China
*
Author for correspondence: Yongdong Li, Key Laboratory for Physical Electronics and Devices of the Ministry of Education, School of Electronic and Information Engineering, Xi'an Jiaotong University, Xi'an 710049, China. E-mail: leyond@mail.xjtu.edu.cn

Abstract

High inductive helical support provides a solution to controlling the alignment error of inner electrodes in magnetically insulated transmission lines (MITLs). Three-dimensional particle-in-cell simulations were performed to examine the current loss mechanism and the effects of structural parameters on electron flow in an MITL with a helical inductor. An empirical expression related to the ratio of electron current loss to anode current and the ratio of anode current to self-limited current was obtained. Electron current loss caused by helical inductor with different structures was displayed. The results indicate that the current loss in an MITL, near an inductive helical support, comprises both the inductor current and the electron current loss. The non-uniform structure and current of a helical inductor cause an abrupt change in the magnetic field near the helical support, which leads to anomalous behavior and current loss of electron flow. In addition, current loss in the inductive helical-supported MITL is negligible when the inductance of the support is sufficiently high. This work facilitates the estimation of electron current loss caused by the inductive helical support in MITLs.

Information

Type
Research Article
Copyright
Copyright © Cambridge University Press 2019 
Figure 0

Fig. 1. Simulation model of high inductive helical-supported MITL.

Figure 1

Fig. 2. Time histories of voltage and current for the helical-supported MITL with d = 21 mm. The inductance is 26.5 µH.

Figure 2

Fig. 3. Current loss of the helical-supported MITL with d = 21 mm. The inductance is 26.5 µH.

Figure 3

Fig. 4. Snapshots of electrons in the MITL in the YZ plane at 100 ns. d is 21 mm in (a) and 18 mm in (b). The inductance is 26.5 µH.

Figure 4

Fig. 5. Magnitude of magnetic fields of (a) absolute value, (b) Bx, and (c) By in the MITL of Figure 4a in the YZ plane at 100 ns, d = 21 mm.

Figure 5

Fig. 6. Magnitude of magnetic fields of (a) absolute value, (b) Bx, and (c) By in the MITL of Figure 4a in the XY plane at 100 ns, d = 21 mm.

Figure 6

Fig. 7. Snapshots of electrons in the MITL of Figure 4 in the XY plane at 100 ns. (a), (b), and (c) describe the particle plots at cross-sections of z = 0.3 m, z = 0.5 m, and z = 0.7 m when d = 21 mm, respectively. (d), (e), and (f) describe the particle plots at cross-sections of z = 0.3 m, z = 0.5 m, and z = 0.7 m when d = 18 mm, respectively.

Figure 7

Fig. 8. Electron current for the MITL in Figure 4a at different positions in the z direction.

Figure 8

Fig. 9. Plots of $I_{\rm e}^{{\rm Loss}} /I_{\rm a}$ as functions of $I_{\rm a}/I_{\rm a}^{{\rm SL}} $ for simulation results (labeled 0.72 and 4.9 MV) and fitting results. $I_{\rm e}^{{\rm Loss}} $, Ia, and $I_{\rm a}^{{\rm SL}} $ are the electron current loss near the support (0.3 m < z < 0. 7 m), anode current after the support, self-limited current of the MITL, respectively.

Figure 9

Fig. 10. Inductor current for the helical-supported MITL in the self-limited case. The peak voltage is 0.74 MV.

Figure 10

Fig. 11. Electron current loss for the helical-supported MITL in the self-limited case in Figure 10.

Figure 11

Fig. 12. Snapshots of electrons in the MITLs with different inductances in the YZ plane at 100 ns. The MITLs are operated in the self-limited case. The inductance of helical inductors in (a) and (b) are 26.5 and 2.4 µH, respectively.

Figure 12

Fig. 13. Snapshots of (a) electrons and (b) the magnitudes of magnetic fields in the MITLs in Figure 12b in the XY plane at 100 ns.

Figure 13

Fig. 14. Electron current loss versus voltage for MITLs in the self-limited case. The lengths of the helical spring are 12, 24, and 36 cm. The interval between the wings of the helical inductor varies from 4.8 to 9.6 mm.

Figure 14

Fig. 15. Electron current loss versus voltage for MITLs of geometry 3 in the self-limited case. The radius of the helical inductor varies from 20 to 60 mm.

Figure 15

Fig. 16. Magnetic fields of MITLs at the center of the inductor in the (a) YZ plane and (b) XY plane at 100 ns. The MITL is operated in the self-limited case. V = 0.74 MV.

Figure 16

Fig. 17. Magnetic fields of MITLs with (a) 5 cm-radius and (b) 3 cm-radius inductor at 100 ns. The MITL is operated in the self-limited case.

Figure 17

Fig. 18. Electron current loss versus voltage for MITLs in the self-limited case, with different distances from the helical support to the load in (a) and snapshots of electrons in MITL when DSL is 70 cm in (b). The helical spring is the same as that in Figure 4.

Figure 18

Fig. 19. Plots of $I_{\rm e}^{{\rm Loss}} /I_{\rm a}^{{\rm SL}} $ as functions of operating voltage of the MITL with varied (a) distance from support to the load and (b) radius of helical spring. The inductance of the helical spring is 26.5 µH.

Figure 19

Fig. 20. Self-limited impedance as a function of voltage for MITLs with varied-radius springs. The inductance of the helical spring is 26.5 µH.