Hostname: page-component-74656f9884-2dmjx Total loading time: 0 Render date: 2026-11-08T03:24:01.863Z Has data issue: false hasContentIssue false

Extra-cardiac and complex Fontan baffle fenestration using radio frequency current via surgical electrocautery

Published online by Cambridge University Press:  24 April 2023

Asra Khan*
Affiliation:
Pediatric Interventional Cardiology, Baylor College of Medicine, Texas Children’s Hospital, 6651 Main Street, Suite E1920, Houston, TX 77030, USA
Athar M. Qureshi
Affiliation:
Pediatric Interventional Cardiology, Baylor College of Medicine, Texas Children’s Hospital, 6651 Main Street, Suite E1920, Houston, TX 77030, USA
Manish Bansal
Affiliation:
Pediatric Interventional Cardiology, Baylor College of Medicine, Texas Children’s Hospital, 6651 Main Street, Suite E1920, Houston, TX 77030, USA
Gary Stapleton
Affiliation:
Pediatric Interventional Cardiology, Baylor College of Medicine, Texas Children’s Hospital, 6651 Main Street, Suite E1920, Houston, TX 77030, USA
Melissa K. Webb
Affiliation:
Pediatric Interventional Cardiology, Baylor College of Medicine, Texas Children’s Hospital, 6651 Main Street, Suite E1920, Houston, TX 77030, USA
Wilson Lam
Affiliation:
Pediatric Interventional Cardiology, Baylor College of Medicine, Texas Children’s Hospital, 6651 Main Street, Suite E1920, Houston, TX 77030, USA
Lindsay Eilers
Affiliation:
Pediatric Interventional Cardiology, Baylor College of Medicine, Texas Children’s Hospital, 6651 Main Street, Suite E1920, Houston, TX 77030, USA
Harinder R. Singh
Affiliation:
The Children’s Hospital of San Antonio, 333 N. Santa Rosa Street, San Antonio, TX 78207, USA
Srinath T. Gowda
Affiliation:
Pediatric Interventional Cardiology, Baylor College of Medicine, Texas Children’s Hospital, 6651 Main Street, Suite E1920, Houston, TX 77030, USA
*
Author for correspondence: Asra Khan MD, Pediatric Interventional Cardiology, Assistant Professor, Baylor College of Medicine, Texas Children’s Hospital, 6651 Main Street, Suite E1920, Houston, TX 77030, USA. Tel: 8328265682. E-mail: asrak@bcm.edu
Rights & Permissions [Opens in a new window]

Abstract

Background:

Fontan baffle punctures and creation of Fontan fenestration for cardiac catheterisation procedures remain challenging especially due to the heavy calcification of prosthetic material and complex anatomy.

Objectives:

We sought to evaluate our experience using radiofrequency current via surgical electrocautery needle for Fontan baffle puncture to facilitate diagnostic, electrophysiology, and interventional procedures.

Methods:

A retrospective chart review of all Fontan patients (pts) who underwent Fontan baffle puncture using radiofrequency energy via surgical electrocautery from three centres were performed from January 2011 to July 2021.

Results:

A total of 19 pts underwent 22 successful Fontan baffle puncture. The median age and weight were 17 (3–36 years) and 55 (14–88) kg, respectively. The procedural indications for Fontan fenestration creation included: diagnostic study (n = 1), atrial septostomy and stenting (n = 1), electrophysiology study and ablation procedures (n = 8), Fontan baffle stenting for Fontan failure including protein-losing enteropathy (n = 7), and occlusion of veno-venous collaterals (n = 2) for cyanosis. The type of Fontan baffles included: extra-cardiac conduits (n = 12), lateral tunnel (n = 5), classic atrio-pulmonary connection (n = 1), and intra-cardiac baffle (n = 1). A Fontan baffle puncture was initially attempted using traditional method in 6 pts and Baylis radiofrequency trans-septal system in 2 pts unsuccessfully. In all pts, Fontan baffle puncture using radiofrequency energy via electrocautery needle was successful. The radiofrequency energy utilised was (10–50 W) and required 1–5 attempts for 2–5 seconds. There were no vascular or neurological complications.

Conclusions:

Radiofrequency current delivery using surgical electrocautery facilitates Fontan baffle puncture in patients with complex and calcified Fontan baffles for diagnostic, interventional, and electrophysiology procedures.

Information

Type
Original Article
Copyright
© The Author(s), 2023. Published by Cambridge University Press
Figure 0

Figure 1. An illustration of FBP using RF energy via surgical electrocautery system. (a). The cautery blade was connected to the electrocautery system and set to “cutting” mode and desired watts. (b). The trans-septal needle was held and advanced against the chosen point of the FB by the primary operator. (c). The cautery tip is held in contact on the proximal portion of the trans-septal needle by the secondary operator and delivers the selected energy facilitating FBP. FBP; Fontan baffle puncture, FB; Fontan baffle.

Figure 1

Table 1. Demographics, indications, and procedural details in patients with Fontan baffle puncture

Figure 2

Figure 2. A complex extra-cardiac Fontan baffle and native atrial septum puncture for an atrial stent placement. A 7-year-old child with history of restrictive atrial septum, severe mitral stenosis, and failing Fontan. An angiogram demonstrated extra-cardiac Fontan conduit (a), a FBP was performed using RF energy (b) and the sheath was positioned in the RA (c). A TEE demonstrated intact atrial septum (d, arrow) and septal puncture was performed using RF energy (e), and the sheath was advanced to the LA (f). An atrial septal stent was then positioned (g) and deployed across the septum (h). RF; radio-frequency, RA; Right atrium, FBP; Fontan baffle puncture, LA; Left atrium, TEE; Transesophageal echocardiogram.

Figure 3

Figure 3. An extra-cardiac Fontan conduit fenestration creation and stent placement using RIJ vein. Angiograms demonstrated extra-cardiac conduit in two patients (a,e). The FBP was performed from the RIJ approach in both (b,f) due to bilateral femoral vein occlusion using RF energy and stents were positioned (c,g) and deployed (arrows, d,h) successfully. RIJ; Right internal jugular vein, FBP; Fontan baffle puncture.

Figure 4

Figure 4. A FBP was performed on extra-cardiac conduits to access and occlude large venous collaterals. Two patients with history of cyanosis post-Fontan (a, e) underwent FBP (b, f) to access large venous collaterals: LSVC (c) and hemi-azygoys vein (g) draining to the atrium were successfully occluded using vascular plugs (arrows, d,h). LSVC; Left superior vena cava; FBP; Fontan Baffle puncture.

Figure 5

Figure 5. A complex calcified lateral tunnel baffle underwent FBP for an EP study. A 25-year-old male with TA had recurrent IART. (a, b) A CT scan demonstrated a heavily calcified (arrows) lateral tunnel Goretex patch and dilated Fontan baffle on angiogram (c). An attempt to puncture the conduit using Baylis RF system failed as the needle tip fractured (d, arrows). The FBP was performed successfully using trans-septal needle (e) and RF energy delivery using electro-cautery (f). TA; Tricuspid atresia, IART; Intra-atrial reentrant tachycardia; CT; Computerized tomography, RF; Radio frequency; FBP; Fontan Baffle puncture.

Figure 6

Figure 6. A complex lateral tunnel FBP was performed in close proximity to the atrial appendage. (a) An angiogram demonstrating lateral tunnel FB, with successful FBP using RF energy just inferior to an Amplatzer device (b), and the sheath was positioned carefully for ablation at the base of the narrow atrial appendage (white outline). EP; Electrophysiology, RF; radiofrequency, FBP; Fontan Baffle puncture, FB; Fontan baffle.