Hostname: page-component-7b7567c8c-kwt9d Total loading time: 0 Render date: 2026-11-12T07:25:40.872Z Has data issue: false hasContentIssue false

Observations of the dynamic structure of snow avalanches

Published online by Cambridge University Press:  20 January 2017

K. Nishimura
Affiliation:
Institute of Low Temperature Science, Hokkaido University, Sapporo 060, Japan
N. Maeno
Affiliation:
Institute of Low Temperature Science, Hokkaido University, Sapporo 060, Japan
F. Sandersen
Affiliation:
Norwegian Geotechnical Institute, Tasen N-0801, Oslo, Norway
K. Kristensen
Affiliation:
Norwegian Geotechnical Institute, Tasen N-0801, Oslo, Norway
H. Norem
Affiliation:
Norwegian Geotechnical Institute, Tasen N-0801, Oslo, Norway
K. Lied
Affiliation:
Norwegian Geotechnical Institute, Tasen N-0801, Oslo, Norway
Rights & Permissions [Opens in a new window]

Abstract

During two winters, 1990–92, the dynamic structures of snow avalanches were studied in western Norway. Artificially released wet-snow avalanches ran down the avalanche chute and stopped in front of the retaining dam. Running velocity distributions were obtained not only by video tape recorder, but also by various other recording instruments. Internal velocity was derived for the last avalanche by frequency analysis of impact pressure and optical sensor data. The vertical velocity shear of the avalanche flow has been estimated to be in the range 1–10 s−1.

Information

Type
Research Article
Copyright
Copyright © International Glaciological Society 1993
Figure 0

Fig. 1.Cross-section of the Ryggfonn avalanche path.

Figure 1

Fig. 2.Schematic representation of the impact-pressure sensors (a-d) set on the tubular tower.

Figure 2

Fig. 3.Schematic representation of the measuring apparatus set on the concrete structure, e andf impact pressure sensors; g and h, optical sensors.

Figure 3

Fig. 4.Recording of ground vibration during the avalanche on 20 March 1991.

Figure 4

Fig. 5.Front velocity of the avalanches estimated from the video-tapes and the recordings from the sensors.

Figure 5

Fig. 6.Recordings obtained during the passage of the avalanche on 20 May 1992. The units of the vertical axes are arbitrary. A, impact pressure on the tower (d in Fig. 2) ; B, light reflectivity on the concrete structure (g in Fig. 3); C, impact pressure on the concrete structure (measuring plate area is 0.6 × 1.2m2).

Figure 6

Fig. 7.Internal velocity of the avalanche on 20 May 1992. Squares and triangles refer to the velocities calculated from the pair recordings of impact pressures, a and b, and c and d, respectively (Fig. 2).

Figure 7

Fig. 8.Internal velocity of the avalanche on 20 May 1992. Squares refer to the velocities calculatedfrom the recordings of impact pressures (e and ƒ in Fig. 3), and triangles to those calculated from recordings of optical sensor output (g and h).