Hostname: page-component-6898cfcb55-zsp5v Total loading time: 0 Render date: 2026-11-11T16:38:38.820Z Has data issue: false hasContentIssue false

Novel use of a mechanical suction thrombectomy system for interposition graft occlusion in complex congenital heart disease

Published online by Cambridge University Press:  25 November 2021

Preston J. Boyer
Affiliation:
University of Michigan Congenital Heart Center, C.S. Mott Children’s Hospital, Ann Arbor, MI, USA
Jeffrey D. Zampi
Affiliation:
University of Michigan Congenital Heart Center, C.S. Mott Children’s Hospital, Ann Arbor, MI, USA
Arash Salavitabar*
Affiliation:
Nationwide Children’s Hospital, The Heart Center, Department of Pediatrics, The Ohio State University, Columbus, OH, USA
*
Author for correspondence: Arash Salavitabar, MD, FSCAI, FPICS, Cardiac Catheterization & Interventional Therapies, The Heart Center, Nationwide Children’s Hospital, Assistant Professor of Pediatrics, The Ohio State University College of Medicine, Columbus, OH, USA. Tel: +1 614-722-6150; Fax: 614-722-5030. E-mail: arash.salavitabar@nationwidechildrens.org
Rights & Permissions [Opens in a new window]

Abstract

Complete thrombosis of a pulmonary artery interposition graft in an adolescent with complex repaired CHD was treated successfully with a combination of a novel mechanical thrombectomy system, stent implantation, and thrombolysis. This thrombectomy system used a flexible catheter with a built-in mechanism to attenuate blood loss, while providing effective recanalisation of a foreign graft.

Information

Type
Brief Report
Copyright
© The Author(s), 2021. Published by Cambridge University Press
Figure 0

Figure 1.Cardiac catheterisation. A: Complete interposition graft occlusion. B: Extensive interposition graft thrombosis. C: Interposition graft following mechanical thombectomy. D: Interposition graft following stent implantation and thrombolysis.

Figure 1

Figure 2.Mechanical thrombectomy system. A: The Penumbra Indigo Lightning Aspiration System with clot detection indicator. B: Angled catheter tip.