Foreign body ingestion: comparison of diagnostic accuracy of computed tomography versus endoscopy

Published online by Cambridge University Press:  27 November 2008

W-H Luk*
Affiliation:
Department of Diagnostic Radiology and Organ Imaging, United Christian Hospital, Hong Kong SAR
W C Fan
Affiliation:
Department of Diagnostic Radiology and Organ Imaging, United Christian Hospital, Hong Kong SAR
R Y Y Chan
Affiliation:
Department of Diagnostic Radiology and Organ Imaging, United Christian Hospital, Hong Kong SAR
S W W Chan
Affiliation:
Department of Surgery, United Christian Hospital, Hong Kong SAR
K H Tse
Affiliation:
Department of Surgery, United Christian Hospital, Hong Kong SAR
J C S Chan
Affiliation:
Department of Diagnostic Radiology and Organ Imaging, United Christian Hospital, Hong Kong SAR
*
Address for correspondence: Dr Wing-Hang Luk, Department of Diagnostic Radiology and Organ Imaging, United Christian Hospital, 130 Hip Wo Street, Kwun Tong, Kowloon, Hong Kong SAR. Fax: 852 35135637 E-mail: lukwinghang@gmail.com
Rights & Permissions [Opens in a new window]

Abstract

Purpose:

To investigate and compare the sensitivity and specificity of computed tomography and of endoscopy, as diagnostic tests for foreign body ingestion.

Materials and methods:

Over a two-year period, Asian patients with suspected foreign body ingestion were studied. The clinical findings, computed tomography images, endoscopic results, treatment and outcomes were prospectively analysed.

Results:

Over the study period, 193 patients were admitted for foreign body ingestion, complaining of a persistent foreign body sensation in the neck. The sensitivity and specificity of computed tomography were 78 and 96 per cent, respectively; the positive predictive value was 75 per cent and the negative predictive value 97 per cent. The diagnostic accuracy of computed tomography was 94 per cent.

Conclusion:

Our study showed that computed tomography had high negative predictive value and accuracy in the diagnosis of foreign body ingestion. It was useful if endoscopy showed negative findings but the patient still had persistent symptoms of foreign body ingestion.

Information

Type
Main Articles
Copyright
Copyright © JLO (1984) Limited 2008
Figure 0

Fig. 1 Flow chart of study stages. FB = foreign body; +ve = positive; −ve = negative; CT = computed tomography; OGD = oesophagogastroduodenoscopy.

Figure 1

Table I Summary of results

Figure 2

Fig. 2 (a) Transverse computed tomography image showing a linear hyperdensity at the hypopharynx at the level of the hyoid bone (arrow); endoscopy identified this as a foreign body. (b) Fish bone removed at endoscopy, measuring approximately 1.2 cm long.

Figure 3

Table II Types of foreign body ingested

Figure 4

Table III Endoscopic sites of foreign body ingestion within CT range*

Figure 5

Table IV Foreign body detection outcomes for CT and endoscopy

Figure 6

Table V Endoscopic sites of foreign body ingestion outside CT range

Figure 7

Table VI Endoscopic sites of foreign body ingestion missed by CT

Figure 8

Table VII Foreign body detection outcomes for CT and endoscopy, excluding 15 cases with foreign body outside the CT range

Figure 9

Fig. 3 Transverse computed tomography (CT) image showing a small, linear hyperdensity at the posterior hypopharynx at the level of the hyoid bone (arrow). Endoscopy found no foreign body but identified a small haematoma in the same region. The small hyperdensity seen on CT may have been due to a haematoma left after an impacted foreign body had dislodged.

Figure 10

Fig. 4 Transverse computed tomography image showing a small, oval, hyperdense focus at the left oropharynx (arrow), which may have been due to soft tissue calcification. Endoscopy was normal.

Figure 11

Fig. 5 Transverse computed tomography image showing a linear hyperdensity at the cricopharyngeus (arrow), which was missed at initial endoscopy. Repeat endoscopy revealed a foreign body impacted at the cricopharyngeus.