Hostname: page-component-7b7567c8c-tnkh4 Total loading time: 0 Render date: 2026-11-16T23:26:40.740Z Has data issue: false hasContentIssue false

Spanwise localized control for drag reduction in flow passing a cylinder

Published online by Cambridge University Press:  29 March 2021

Xuerui Mao*
Affiliation:
Faculty of Engineering, University of Nottingham, Nottingham NG7 2RD, UK
Bofu Wang
Affiliation:
Faculty of Engineering, University of Nottingham, Nottingham NG7 2RD, UK
*
†Email address for correspondence: maoxuerui@sina.com

Abstract

Active and passive controls for drag reduction in flow around a cylinder are obtained by computing the sensitivity of drag with respect to surface velocity perturbations and roughness, respectively. Both controls are concentrated around the separation line and localized in the spanwise direction, producing suction effects to the separating boundary layers. In the wake, the control induces localized vertical displacements and streamwise stretches of the upper and lower vorticity sheets, and subsequently delay the vortex shedding and push the local pressure minimum away from the cylinder. Instead of suppressing separation and recirculation as commonly observed in two-dimensional controls, the present three-dimensional control extends the recirculation zone to produce a virtual surface converting the bluff body flow to a streamlined body flow. Through this mechanism, the control reduces drag by 20 % at maximum control velocity 2 % of the free-stream velocity (or momentum coefficient $10^{-4}$) at Reynolds number $Re=190$. The control is much more efficient than the previously tested spanwise uniform suction or periodic suction/blowing, both requiring maximum control velocity above 8 % (or momentum coefficient above $10^{-3}$) to achieve similar drag reduction effects. The power savings ratio, defined as the ratio of the control-reduced drag power and the maximum input power, is above 20, up to $Re=1000$, the highest Reynolds number considered in this work. This ratio reduces slightly to 17.8 when the control is simplified to spanwise localized suction around the separation lines in order to facilitate practical implementations.

Information

Type
JFM Papers
Copyright
© The Author(s), 2021. Published by Cambridge University Press
Figure 0

Figure 1.Schematic plot of (a) surface-normal roughness and (b) surface-normal and surface-tangential roughness. Here $r$ represents the roughness. The solid lines denote the smooth surfaces without roughness $\boldsymbol {B}$, dashed lines represent surfaces with roughness $\boldsymbol {B}_r$ and dotted lines illustrate the direction of roughness.

Figure 1

Figure 2.Mesh and boundary conditions in (a) the entire domain and (b) the subdomain around the cylinder. The three components of the control are marked in (b).

Figure 2

Figure 3.Iso-surfaces of spanwise vorticity 0.4 and $-0.4$, coloured by streamwise velocity, in unperturbed flow around a cylinder at $Re=190$. The thick solid lines represent the vortex lines associated with the lower vortex sheet.

Figure 3

Table 1.Convergence of the sensitivity of drag to active perturbations in flow past a cylinder at $Re=190$ and $\omega =0$. (a) The final time is fixed at $\tau =40$ and the polynomial order in the spectral element method is varied. Here $c_{\mathcal {P}}$ is a correlation factor defined in (3.1). (b) The polynomial order is fixed at $\mathcal {P}=6$ and the final time is varied. Here $c_{\tau }(\tau _1,\tau _2)$ as defined in (3.2) denotes the correlation of sensitivities obtained at two final times.

Figure 4

Figure 4.Contours of the sensitivity to active perturbations normalized by the boundary norm at $Re=190$ and $\omega =0$. Panels (a,b,c) are the wall-normal, azimuthal and spanwise components of the sensitivity, respectively. The dash-dotted lines represent the mean separation lines.

Figure 5

Figure 5.Contours of the wall-normal component of the sensitivity normalized by the boundary norm at $Re=190$, $\omega =0$ and spanwise length 4, 8 and 12 for (a,b,c), respectively. The dash-dotted lines represent the mean separation lines.

Figure 6

Figure 6.The active control scaled from sensitivity at $S_a=-7 \times 10^{-3}$, $\omega =0$ and $Re=190$. (a) Spanwise distribution at various azimuthal locations and (b) dominant spanwise modes, with $\beta$ denoting the spanwise wavenumber.

Figure 7

Figure 7.Drag reduction at $Re=190$ and various control magnitudes. The control is scaled from sensitivity of drag to wall-normal active perturbations at $\omega =0$ (see figure 4a). The drag coefficient, denoted as $\hat {C}_D$, is averaged over the spanwise direction and will be used in all the following relevant plots.

Figure 8

Figure 8.Drag reduction induced by individual spanwise modes of the control. In panel (a), the control is the spanwise-decomposed components of the scaled sensitivity of drag to wall-normal active perturbations at $Re=190$, $\omega =0$ and $S_a=-7 \times 10^{-3}$ (see figure 6b). In panel (b), all the individual modes are scaled to boundary norm $7 \times 10^{-3}$.

Figure 9

Figure 9.Controlled drag coefficients at various Reynolds numbers. The control is scaled from sensitivity of drag to wall-normal active perturbations at $\omega =0$, $S_a=-7 \times 10^{-3}$ and $Re=190$.

Figure 10

Table 2.The uncontrolled drag coefficient ($\hat {C}_D$ at $S_a=0$), controlled drag coefficient ($\hat {C}_D$ at $S_a=-7 \times 10^{-3}$), ideal actuation power, maximum actuation power and power savings ratio at various Reynolds numbers. The control is scaled from the sensitivity of drag to wall-normal perturbations at $Re=190$ and $\omega =0$. The power savings ratio is defined as the ratio of the control-reduced drag and the maximum actuation power $\dot {W}_{B\text {-}max}$.

Figure 11

Figure 10.Distribution of the simplified control. Positive contour levels denote suction control.

Figure 12

Figure 11.Drag reduction under the simplified control in figure 10.

Figure 13

Figure 12.Contours of the instantaneous spanwise vorticity on the $z=0$ plane. The black circles mark the points where pressure reaches local minimum. The control is scaled from the wall-normal sensitivity at $Re=190$ and $\omega =0$, and the magnitude of the control is $S_a=0$ (without control), $-5 \times 10^{-3}$ and $-7 \times 10^{-3}$ for (a,b,c), respectively.

Figure 14

Figure 13.Streamlines and pressure contours in the spanwise and temporally averaged flow. The control is scaled from the wall-normal sensitivity at $Re=190$ and $\omega =0$, and the magnitude of the control is $S_a=0$ (without control), $-5 \times 10^{-3}$ and $-7 \times 10^{-3}$ for (a,b,c), respectively.

Figure 15

Figure 14.Spanwise and temporally averaged distribution of the pressure on the surface of the cylinder. In the controlled cases, the control magnitude is $S_a=-7 \times 10^{-3}$.

Figure 16

Figure 15.Iso-surfaces of spanwise vorticity 0.5 (red) and $-0.5$ (blue) at $S_a=-7 \times 10^{-3}$ and $Re=190$. Panels (a,b,c) are 3-D, side ($x$–$y$ plane) and top ($x$–$z$ plane) views of the same surface, respectively. The flow field is repeated in $z$ to highlight the spanwise variation. The thick solid lines in panel (a) represent the vortex lines associated with the lower vortex sheet.

Figure 17

Figure 16.Schematics of the drag reduction mechanism. Panel (a) is the vortex shedding at $z=0$ showing the uncontrolled scenario; panel (b) shows the suction effect of the control and its induced $y$-displacement; panel (c) illustrates the displacement induced velocity in the streamwise direction; panel (d) presents the stretch in streamwise direction owing to the induced velocity. Lengths of the arrows in panel (c) represent the magnitude of the induced velocity. Blue and red denote negative and positive vorticity, respectively.

Figure 18

Figure 17.Panel (a) is the contour of the sensitivity to wall-normal passive perturbations normalized by its boundary norm at $Re=190$. The dash-dotted lines represent the mean separation lines. Panel (b) is the surface of the cylinder with roughness scaled from the sensitivity at $S_r=-0.04$.

Figure 19

Figure 18.Passively controlled drag coefficient at $Re=190$. The control is scaled from the passive sensitivity of drag to wall-normal roughness. The surface with passive control at $S_r=-0.04$ has been illustrated in figure 17(b).

Figure 20

Figure 19.Drag coefficients under passive control (see figure 17(b) for the deformed geometry) at various Reynolds numbers. The control is scaled from the sensitivity of drag to wall-normal roughness at $S_r=-0.04$ and $Re=190$.