Hostname: page-component-7b7567c8c-7pwfn Total loading time: 0 Render date: 2026-11-15T19:04:35.235Z Has data issue: false hasContentIssue false

Early transition, relaminarization and drag reduction in the flow of polymer solutions through microtubes

Published online by Cambridge University Press:  10 January 2020

Bidhan Chandra
Affiliation:
Department of Chemical Engineering, Indian Institute of Technology, Kanpur, 208016, India
V. Shankar*
Affiliation:
Department of Chemical Engineering, Indian Institute of Technology, Kanpur, 208016, India
Debopam Das
Affiliation:
Department of Aerospace Engineering, Indian Institute of Technology, Kanpur, 208016, India
*
†Email address for correspondence: vshankar@iitk.ac.in

Abstract

Experiments are performed to investigate the onset of early transition and drag reduction in the flow of polymer (polyacrylamide and polyethylene oxide) solutions through rigid microtubes of diameters in the range 0.49–2.84 mm. We measure friction factor variation with Reynolds number for varying polymer concentrations and tube diameters, and the Reynolds number, $Re_{t}$, at which the experimental data deviate from the laminar value represents the onset of transition. Crucially, owing to the high shear rates encountered in our experiments, we show that it is important to account for shear thinning of the fluid in the theoretical estimation of the friction factor in the laminar regime. We accomplish this using a Carreau model, and show that the use of laminar friction factor calculated without shear thinning leads to an erroneous overestimation of $Re_{t}$. The $Re_{t}$ obtained from friction factor data in the present study is in good agreement with that inferred using micro particle image velocimetry analysis in Chandra et al. (J. Fluid Mech., vol. 844, 2018, pp. 1052–1083). For smaller concentrations of the added polymer, there is a marginal delay in the onset of turbulence, but as the concentration is increased further, the transition Reynolds number decreases much below $2000$, the usual value at which transition occurs in Newtonian pipe flows. Thus, the present study further corroborates the phenomenon of early transition leading to an ‘elasto-inertial’ turbulent state in the flow of polymer solutions. For concentrations such that there is a delay in transition, if $Re$ is maintained above the $Re_{t}$ for Newtonian fluids, the flow is transitional or turbulent in the absence of polymers. At such a fixed $Re$, if the concentration of the polymer is increased gradually, the friction factor decreases and the flow relaminarizes. With further increase in polymer concentration, the flow undergoes a transition due to elasto-inertial instability. The effect of addition of small amounts of polymer on turbulent drag reduction in the flow of water through microtubes is also investigated. Increase in polymer concentration, molecular weight and decrease in tube diameter causes an increase in drag reduction. The friction factor data for different polymer concentrations, molecular weights, tube diameters and $Re$, when plotted with $Wi(1-\unicode[STIX]{x1D6FD})$, show a reasonable collapse, where $Wi$ is the Weissenberg number defined as the product of the longest relaxation time of the polymer solution and the average shear rate in the tube and $\unicode[STIX]{x1D6FD}$ is the ratio of solvent to total solution viscosity. Interestingly, the onset of the maximum drag reduction asymptote, for experiments using varying tube diameters and polymer concentrations, appears to occur at $Wi(1-\unicode[STIX]{x1D6FD})\sim O(1)$.

Information

Type
JFM Papers
Copyright
© The Author(s), 2020. Published by Cambridge University Press
Figure 0

Figure 1.Schematic figure showing the fabrication protocol for the preparation of tubular bore in a PDMS block.

Figure 1

Figure 2.Experimental set-up for measuring pressure for flow through the 0.49 mm micro-tube. For larger diameters of tubes i.e. 1.24 mm and 2.84 mm, glass tubes have been used.

Figure 2

Figure 3.Comparison of present friction factor results with those of Neelamegam & Shankar (2015). Solid line represents the laminar line and dashed line is the turbulent Blasius line. Panel (b) represents the normalized deviation in friction factor from its laminar value as a function of $Re$.

Figure 3

Figure 4.Friction factor data for 500 ppm solution taken from Samanta et al. (2013). Solid line represents the Carreau fit for the 500 ppm PAAm solution used in the experiments and dashed line depicts the laminar regime for a Newtonian fluid without shear thinning. Inset shows the same plot in a linear scale near to the transition regime. The vertical dotted line shows the $Re$ at which the friction factor data deviate from the laminar friction factor data (corrected for shear thinning). Panel (b) represents the normalized deviation in friction factor from its laminar value as a function of $Re$.

Figure 4

Figure 5.Friction factor charts for 100 ppm PAAm solutions. Solid line depicts the numerical Carreau model fitting for the corresponding concentration of polymer used. Dotted line depicts the laminar regime for a Newtonian fluid without the effect of shear thinning. Dotted line with symbol on top is an indicator for the onset of transition as marked by a deviation from the laminar Carreau model prediction. Panel (b) represents the normalized deviation in friction factor from its laminar value as a function of $Re$.

Figure 5

Figure 6.Friction factor charts for (a) 300 ppm and (c) 400 ppm PAAm solutions. The solid line depicts the numerical Carreau model fitting corresponding to the concentration of polymer used. The dotted line depicts the laminar prediction for a Newtonian fluid without shear thinning. Dotted vertical line with symbol on top is an indicator for the onset of transition as marked by a deviation from the laminar Carreau model prediction. For the 300 ppm solution, the MDR asymptote is also plotted and our experimental data (for $Re>2500$) approach this asymptote. Panels (b,d) represent the normalized deviation in friction factor from its laminar value at the given $Re$ for 300 ppm PAAm and 400 PAAm respectively.

Figure 6

Figure 7.Friction factor chart for 800 ppm PAAm solution. Solid line depicts the numerical Carreau model fitting corresponding to the concentration of polymer used. Dotted line depicts the laminar prediction for a Newtonian fluid without shear thinning. The dotted vertical line with symbol on top is an indicator for the onset of transition as marked by a deviation from the laminar Carreau model prediction. Panel (b) represents the normalized deviation in friction factor from its laminar value as a function of $Re$.

Figure 7

Figure 8.Friction factor for 600 ppm PAAm solution for flow through 2.84 mm tube. Solid line depicts the numerical Carreau model fitting corresponding to the concentration of polymer used. Dotted line depicts the laminar prediction for a Newtonian fluid without shear thinning. Dotted vertical line with symbol on top is an indicator for the onset of transition as marked by a deviation from the laminar Carreau model prediction. Panel (b) represents the normalized deviation in friction factor from its laminar value as a function of $Re$.

Figure 8

Figure 9.Friction factor charts for 300 ppm PEO solutions. Solid line depicts the numerical Carreau model fitting corresponding to the concentration of polymer used. Dotted line depicts the laminar prediction for a Newtonian fluid without the effect of shear thinning. Dotted vertical line with symbol on top is an indicator for the onset of transition as marked by a deviation from the laminar Carreau model prediction. Panel (b) represents the normalized deviation in friction factor from its laminar value as a function of $Re$.

Figure 9

Figure 10.Variation of $Re_{t}$ with the dimensionless group $E(1-\unicode[STIX]{x1D6FD})$ for different polymer solutions and tube diameters. The $Re_{t}$ obtained using friction factor measurements in the present study are consistent with those obtained from the micro-PIV measurements of Chandra et al. (2018).

Figure 10

Table 1.Variation of $Re_{t}$ with polymer concentration for PAAm solutions for two different tube diameters 0.49 mm and 2.84 mm. The uncertainty in obtaining $Re_{t}$ is less than $\pm 10$.

Figure 11

Figure 11.Normalized deviation in friction factor as a function of normalized deviation of $Re$ from $Re_{t}$ for 300 ppm, 400 ppm and 800 ppm PAAm solutions. The solid lines represent power law fitting with $(Re/Re_{t}-1)^{1/2}$ which is suggestive of a supercritical bifurcation.

Figure 12

Table 2.Variation of $Re_{t}$ with polymer concentration for PEO solutions for two different tube diameters 0.49 mm and 2.84 mm. The uncertainty in obtaining $Re_{t}$ is less than $\pm 10$.

Figure 13

Figure 12.(a) Friction factor chart for the flow of 0–30 ppm PAAm solutions through 0.49 mm tube and (b) 0.5–20 ppm PEO solutions. Solid line represents the friction factor corresponding to the Fanning friction factor when the flow is laminar for a tube which scales as $f=16/Re$.

Figure 14

Figure 13.Friction factor chart for 0–50 ppm PAAm solution for a 2.84 mm tube. Solid line represents the friction factor corresponding to the Fanning friction factor when the flow is laminar for a tube which scales as $f=16/Re$.

Figure 15

Figure 14.(a) Friction factor for the flow of PAAm solution through 0.49 mm tube as a function of concentration represented on a friction factor versus $Re$ chart and (b) friction factor ratio versus concentration plot for $Re=3150$. (c) Friction factor ratio versus $Wi(1-\unicode[STIX]{x1D6FD})$ plot for $Re=2030$ and 2050 from the present experiments, and for the data from the DNS for viscoelastic channel flow by Shekar et al. (2019) at $Re=1500$. (d) Schematic showing a comparison of variation of $Re_{t}$ versus concentration for the present study, Samanta et al. (2013) and Choueiri et al. (2018).

Figure 16

Figure 15.(a) Friction factor for the flow of PAAm solution (procured from Polysciences Europe GmbH, Lot no. 709190) through 2.84 mm tube as a function of concentration (30–80 ppm) represented on a friction factor versus $Re$ chart and (b) friction factor versus concentration plot.

Figure 17

Figure 16.A comparison of friction factor values at $Re=3150$ with varying concentrations of polymer for polymer procured from two different manufacturers.

Figure 18

Figure 17.A comparison of friction factor values at $Re=3150$ and $Re=3600$ with varying concentrations of polymer for polymer procured from Polysciences for two different tube diameters i.e. 2.84 mm and 1.44 mm.

Figure 19

Figure 18.Velocity profile comparison of pure water turbulence at $Re=3150$ when compared to a drag-reduced state by the addition of 5–20 ppm PAAm at $Re=3150$. Continuous line represents laminar velocity profile for a Newtonian fluid. Here $V$ is the local velocity obtained from micro-PIV and $V_{avg}$ is the cross-sectional average velocity obtained from the flow rate measurements. Panel (b) shows the asymmetry in velocity profile for the flow of 20ppm PAAm solution at $Re=3150$. Symbols in panel (b) represent the reflection about $x=0$. Velocity profile for the flow of pure water does not show any asymmetry.

Figure 20

Figure 19.Comparing friction factor values for a fixed $Re=3150$ for different tube diameters for PAAm and PEO for different $Wi$ (different polymer concentrations) when the relaxation time for all concentrations is taken as the Zimm relaxation time (a) linear plot and (b) semi-log plot.

Figure 21

Figure 20.Comparing friction factor values for a fixed $Re=3150$ for different tube diameters for PAAm and PEO for different $Wi$ (different polymer concentrations) when relaxation time is inferred from CaBER relaxation time data (a) linear plot and (b) semi-log plot.

Figure 22

Figure 21.(a) Variation of per cent drag reduction, as calculated using the difference in pressure drop for polymeric and Newtonian flows for a given flow rate, with $Wi$ for different $Re$, different concentrations and different tube diameters; (b) variation of friction factor with varying $Wi$ for different $Re$, different concentrations and different tube diameter. Here, CaBER relaxation time is used for the calculation of $Wi$, and (c) (semi-log) and (d) (linear) plot of percentage reduction in friction factor in the drag-reduced state as compared to the Newtonian case plotted as a function of $Wi(1-\unicode[STIX]{x1D6FD})$.

Figure 23

Table 3.Table showing the value of $Wi(1-\unicode[STIX]{x1D6FD})$ and $Wi_{\unicode[STIX]{x1D70F}}(1-\unicode[STIX]{x1D6FD})$ required for the onset of MDR in the experimental studies of Samanta et al. (2013) (tubes), Owolabi et al. (2017) (tubes and channels) and the present work (tubes). The work of Xi & Graham (2010) and Housiadas & Beris (2013) are DNS studies of viscoelastic channel flows.

Figure 24

Figure 22.A comparison of results obtained from micro-PIV from Chandra et al. (2018), friction factor data from the present study and normalized pressure fluctuation data from Samanta et al. (2013). The lack of data collapse for different tube diameters suggests that shear thinning is important for the smaller tube diameters used.

Figure 25

Figure 23.Friction factor, $f_{Carreau}$, obtained using the Carreau model approaching the Newtonian friction factor value at low $Re$ and showing a deviation at higher $Re$, where $Re$ is calculated using the zero-shear viscosity of the polymer solution. The green dotted line represents the laminar Newtonian ($f_{Newtonian}$) result based on polymer solution viscosity, while the red dotted line represents the Newtonian friction factor ($f_{water}$) calculated using the solvent viscosity (i.e. pure water). The solid line represents the friction factor result from the Carreau model with the following parameters: (i) zero-shear viscosity, $\unicode[STIX]{x1D702}_{0}=0.002~\text{Pa}~\text{s}$, obtained from rheological measurements, (ii) power law index, $n=0.8$ which is obtained by fitting the Carreau model prediction with experimental data at lower $Re$, (iii) the elasticity number is calculated as $E=(\unicode[STIX]{x1D706}_{0}\unicode[STIX]{x1D702}_{0})/\unicode[STIX]{x1D70C}D^{2}=0.017$ and (iv) $\unicode[STIX]{x1D6FD}=0.45$ is the ratio of solvent to solution viscosity. To aid comparison, we also show the corresponding variation of $\unicode[STIX]{x1D702}/\unicode[STIX]{x1D702}_{\infty }$ with $Re$ at a fixed $E$, which explains the approach to the two asymptotic limits at low and high $Re$.