Successful ductal stent implantation for initial palliation in two patients with aortic atresia and interrupted aortic arch

Published online by Cambridge University Press:  13 March 2024

Ensar Duras*
Affiliation:
Department of Pediatric Cardiology, University of Health Sciences, Istanbul Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Center, İstanbul, Turkey
Hacer Kamali
Affiliation:
Department of Pediatric Cardiology, University of Health Sciences, Istanbul Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Center, İstanbul, Turkey
Selman Gokalp
Affiliation:
Department of Pediatric Cardiology, University of Health Sciences, Istanbul Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Center, İstanbul, Turkey
Aysel Turkvatan
Affiliation:
Department of Radiology, University of Health Sciences, Istanbul Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Center, İstanbul, Turkey
Alper Guzeltas
Affiliation:
Department of Pediatric Cardiology, University of Health Sciences, Istanbul Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Center, İstanbul, Turkey
*
Corresponding author: E. Duras; Email: ensarduras@gmail.com
Rights & Permissions [Opens in a new window]

Abstract

The coexistence of aortic valve atresia and interrupted aortic arch are an extremely rare condition. In this pathology, blood flow to the ascending aorta and coronary arteries should be provided through the ductus arteriosus or collaterals originating from the descending aorta. In rare cases where bilateral ductus arteriosus is present, they can provide circulation. Here, we report two cases in which coronary arteries and ascending aorta were supplied by one ductus arteriosus and distal systemic circulation is supplied by a second ductus arteriosus in one patient and a collateral artery in the other. Initial palliation was successfully performed by bilateral pulmonary artery banding and transcatheter ductal stent implantation in both cases.

Information

Type
Brief Report
Copyright
© The Author(s), 2024. Published by Cambridge University Press
Figure 0

Figure 1. (a) CT angiogram 3DVR images show interrupted aortic arch type C with right arterial ductus continues as descending aorta and a left-sided ductus arteriosus supplying the head and neck vessels, hypoplastic ascending aorta. (b) Angiogram shows right ductus arteriosus with 8x17-mm stent deployed; left ductus arteriosus with 7x19-mm stent deployed. MPA = main pulmonary artery; R-PDA = right ductus arteriosus; RSA = right subclavian artery; RCA = right common carotid artery; DAo = descending aorta; LCA = left common carotid artery; LSA = left subclavian artery; L-PDA = left ductus arteriosus; AAo = ascending aorta.

Figure 1

Figure 2. (a) CT angiogram 3DVR images show interrupted aortic arch type between the ascending and descending aorta, an abnormally wide collateral artery acts like a second ductus arteriosus, a large ductus arteriosus originating from the main pulmonary artery continued as descending aorta. (b) Angiogram shows ductus arteriosus with 9x17-mm stent deployed, the ascending aorta and coronary arteries were filling retrogradely from this collateral artery. MPA = main pulmonary artery; AAo = ascending aorta; CA = collateral artery; PDA = patent ductus arteriosus; RSA = right subclavian artery; RCA = right common carotid artery; LCA = left common carotid artery; LSA = left subclavian artery.