Hostname: page-component-74656f9884-npj9w Total loading time: 0 Render date: 2026-11-08T00:10:02.837Z Has data issue: false hasContentIssue false

Transient transmission oscillations in doped and undoped lithium niobate induced by near-infrared femtosecond pulses

Published online by Cambridge University Press:  09 November 2018

Bryan J. Crossman
Affiliation:
Department of Physics, College of St. Benedict/St. John’s University, Collegeville, Minnesota 56321, USA
Gregory J. Taft*
Affiliation:
Department of Physics, College of St. Benedict/St. John’s University, Collegeville, Minnesota 56321, USA
*
a)Address all correspondence to this author. e-mail: gtaft@csbsju.edu

Abstract

Transient transmission oscillations in X-cut and Z-cut congruent, iron-doped, and magnesium-doped lithium niobate samples were measured using 50 fs, 800 nm, 0.5 nJ pulses from a self-mode-locked Ti:sapphire laser in an optical pump–probe system. Several Raman-active oscillation modes excited by these pulses were observed as changes in the transmitted probe intensity versus time delay between the pump and probe pulses. The samples were rotated to determine how the incident polarization of the pump pulses affects the mode excitations. The observed Raman-active oscillations correspond to previously reported symmetry modes measured with traditional, continuous-wave, Raman spectroscopy using the same scattering geometry. In addition, a polariton mode and other, previously unreported, lower-frequency modes were observed in each of the samples. The transmission intensity data for each sample were fit successfully to a superposition of sinusoidal functions with exponentially decaying amplitudes.

Information

Type
Article
Copyright
Copyright © Materials Research Society 2018 
Figure 0

FIG. 1. Diagram of pump–probe system.

Figure 1

FIG. 2. Experimental determination of interaction between pump and probe pulses (cross-correlation) in the sample: (a) measured cross-correlation using a second-harmonic-generation crystal and (b) full scan of transmitted probe light using a Z-cut CLN crystal showing the large nonlinear signal occurring only when the pump and probe pulses are both in the sample.

Figure 2

FIG. 3. (a) Scan data taken for Z-cut CLT with pump polarization in both the X and Y directions and (b) accompanying FFT for each of the scans.

Figure 3

FIG. 4. Increasing the average pump power causes a proportional change in the FFT maximum intensity. The plots show (a) FFTs of transmission scans using the Z-cut CLN with X pump polarization with varying power and (b) a linear fit of maximum FFT intensity versus average pump power.

Figure 4

FIG. 5. Observation of how the (a) scans and (b) corresponding FFTs change when rotating the CLN sample about the Z-cut face.

Figure 5

FIG. 6. (a) Transmission scans of X-cut CLN samples using both polarizations of pump pulses and (b) FFTs associated with each scan.

Figure 6

FIG. 7. Observation of the effects of doping on lithium niobate samples. Each sample was Z-cut with pump polarization in the X-direction. The graphs show (a) the time-resolved transmission change for CLN and two types of doping and (b) FFTs for each of these scans.

Figure 7

FIG. 8. Fit to the Z-cut CLN scan with pump polarization in the X-direction. The fit function is a superposition of decaying sinusoidal functions. In the case of this fit, there are four frequencies used to recreate the scan. The fit parameters for each of the Z-cut scans are shown in Table I.

Figure 8

TABLE I. Fit parameters used to reproduce the dynamic transmission data for all Z-cut scans using both X and Y pump polarizations.

Figure 9

TABLE II. Fit parameters used to reproduce the dynamic transmission data for the X-cut CLN scans using both X and Y pump polarizations.