Certification of Standard Reference Material 1976B

Published online by Cambridge University Press:  12 August 2015

David R. Black*
Affiliation:
National Institute of Standards and Technology, Gaithersburg, Maryland 20899
Donald Windover
Affiliation:
National Institute of Standards and Technology, Gaithersburg, Maryland 20899
Marcus H. Mendenhall
Affiliation:
National Institute of Standards and Technology, Gaithersburg, Maryland 20899
Albert Henins
Affiliation:
National Institute of Standards and Technology, Gaithersburg, Maryland 20899
James Filliben
Affiliation:
National Institute of Standards and Technology, Gaithersburg, Maryland 20899
James P. Cline
Affiliation:
National Institute of Standards and Technology, Gaithersburg, Maryland 20899
*
a) Author to whom correspondence should be addressed. Electronic mail: david.black@nist.gov

Abstract

The National Institute of Standards and Technology (NIST) certifies a suite of Standard Reference Materials (SRMs) to address specific aspects of the performance of X-ray powder diffraction instruments. This report describes SRM 1976b, the third generation of this powder diffraction SRM. SRM 1976b consists of a sintered alumina disc, approximately 25.6 mm in diameter by 2.2 mm in thickness, intended for use in the calibration of X-ray powder diffraction equipment with respect to line position and intensity as a function of 2θ-angle. The sintered form of the SRM eliminates the effect of sample loading procedures on intensity measurements. Certified data include the lattice parameters and relative peak intensity values from 13 lines in the 2θ region between 20° and 145° using CuKα radiation. A NIST-built diffractometer, incorporating many advanced and unique design features was used to make the certification measurements.

Information

Type
Technical Articles
Copyright
Copyright © International Centre for Diffraction Data 2015 
Figure 0

Figure 1. (Color online) Deviations in relative intensity values obtained from profile fitting compared with those obtained from the observed structures factors via GSAS.

Figure 1

Table I. Average relative intensity values for each data analysis method.

Figure 2

Table II. Certified relative intensity data from SRM 1976b.

Figure 3

Table III. Certified lattice parameters of SRM 1976b.

Figure 4

Table IV. Ancillary peak position data for SRM 1976b, lines listed with a relative intensity >5%, computed using CuKα radiation, λ = 0.154 059 29 nm.

Figure 5

Table V. Ancillary biased relative intensity data for SRM 1976b.