Hostname: page-component-74656f9884-8rzl6 Total loading time: 0 Render date: 2026-11-06T08:05:49.937Z Has data issue: false hasContentIssue false

Classification of pseudocalcium visual responses from mouse retinal ganglion cells

Published online by Cambridge University Press:  10 November 2021

H. Shabani
Affiliation:
Institute for Ophthalmic Research, Centre for Ophthalmology, Eberhard Karls University, Tübingen, Germany
Mahdi Sadeghi
Affiliation:
Institute for Ophthalmic Research, Centre for Ophthalmology, Eberhard Karls University, Tübingen, Germany
E. Zrenner
Affiliation:
Institute for Ophthalmic Research, Centre for Ophthalmology, Eberhard Karls University, Tübingen, Germany Werner Reichardt Centre for Integrative Neuroscience (CIN), Tübingen, Germany
D.L. Rathbun*
Affiliation:
Institute for Ophthalmic Research, Centre for Ophthalmology, Eberhard Karls University, Tübingen, Germany Department of Ophthalmology, Detroit Institute of Ophthalmology, Henry Ford Health System, Detroit, Michigan
Z. Hosseinzadeh*
Affiliation:
Department of Molecular and Cellular Mechanisms of Neurodegeneration, Paul Flechsig Institute for Brain Research, University of Leipzig, Leipzig, Germany
*
Corresponding author: D.L. Rathbun,e-mail: drathbu2@hfhs.org; Z. Hosseinzadeh, e-mail: Zohreh.Hosseinzadeh@medizin.uni-leipzig.de
Corresponding author: D.L. Rathbun,e-mail: drathbu2@hfhs.org; Z. Hosseinzadeh, e-mail: Zohreh.Hosseinzadeh@medizin.uni-leipzig.de
Rights & Permissions [Opens in a new window]

Abstract

Recently, a detailed catalog of 32 retinal ganglion cell (RGC) visual response patterns in mouse has emerged. However, the 10,000 samples required for this catalog—based on fluorescent signals from a calcium indicator dye—are much harder to acquire from the extracellular spike train recordings underlying our bionic vision research. Therefore, we sought to convert spike trains into pseudocalcium signals so that our data could be directly matched to the 32 predefined, calcium signal-based groups. A microelectrode array (MEA) was used to record spike trains from mouse RGCs of 29 retinas. Visual stimuli were adapted from the Baden et al. study; including moving bars, full-field contrast and temporal frequency chirps, and black–white and UV-green color flashes. Spike train histograms were converted into pseudocalcium traces with an OGB-1 convolution kernel. Response features were extracted using sparse principal components analysis to match each RGC to one of the 32 RGC groups. These responses mapped onto of the 32 previously described groups; however, some of the groups remained unmatched. Thus, adaptation of the Baden et al. methodology for MEA recordings of spike trains instead of calcium recordings was partially successful. Different classification methods, however, will be needed to define clear RGC groups from MEA data for our bionic vision research. Nevertheless, others may pursue a pseudocalcium approach to reconcile spike trains with calcium signals. This work will help to guide them on the limitations and potential pitfalls of such an approach.

Information

Type
Research Article
Copyright
© The Author(s), 2021. Published by Cambridge University Press
Figure 0

Fig. 1. Sample raw data and equivalent pseudocalcium trace. (a) 100 ms of filtered voltage recording excerpted from (d). (b) Average of extracellular action potentials (mean ± s.d.). Dashed lines highlight baseline and peak. (c) OGB kernel. (d) 11 s sample of filtered data from an ON cell in response to the cycling flash stimulus. (e) Rastergram of spike times for this cell (note excluded spikes around 25 s assigned to a different cell). (f) Pseudocalcium trace produced by convolving the rastergram (e) with the OGB kernel (c).

Figure 1

Fig. 2. Pseudocalcium trace generation for the chirp stimulus. (a) Stimulus brightness over time including 3 s ON and 3 s OFF full-field flash; gray, and two “chirps” composed of increasing frequency and increasing contrast respectively. (Vertical dashed lines separate various stimuli as well as the mean gray background). (b) Raster of spike times across multiple repetitions of the stimulus. (c) Peri-stimulus time histogram (PSTH) of these spike times across all trials using 100 ms time bins. (d) Pseudocalcium trace generated by convolving the rastergrams with the OGB kernel and averaging across trials.

Figure 2

Fig. 3. Average time varying calcium signals for the 49 RGC clusters reported in Baden et al. (2016) (left) average pseudocalcium signals for the spiking data assigned to these clusters from our present dataset (middle), and from an expanded dataset (right). Each trace was normalized to its respective peak. Value at left of each cluster is the percent of RGCs assigned to each cluster, rounded up. Clusters were combined to produce the 32 distinct RGC groups (indicated at far left), and loosely organized with OFF cells near the top, ON–OFF cells in the middle, and ON cells at the bottom. Vertical dashed lines separate stimuli from one another and from baseline responses to the mean gray background stimulus. The segments in order were: gray, white (ON), black (OFF), gray, frequency chirp, gray, contrast chirp, gray (and black), drifting bar, green, black, blue, and black.

Figure 3

Fig. 4. Response of classified cells to electrical noise stimulus. (left) Cluster averages for only the cells with significant electrical STAs, taken from Fig. 3, right. (Order of visual stimuli is as in Fig. 3). (right) Electrical STAs averaged across all cells assigned to the cluster. For each STA, horizontal line represents the stimulus mean of −800 mV. Traces above this line indicate that stimuli preceding spikes were on average a higher (less negative) voltage, traces below the line reflect more negative voltages. STA amplitudes were scaled to show detail. Traces to the right of time zero reflect the variation of random noise.