Label-free RF biosensors for human cell dielectric spectroscopy

Published online by Cambridge University Press:  19 January 2010

Claire Dalmay*
Affiliation:
XLIM Research Institute, Centre National de la Recherche Scientifique (CNRS), University of Limoges, 87060 Limoges Cedex, France.
Arnaud Pothier
Affiliation:
XLIM Research Institute, Centre National de la Recherche Scientifique (CNRS), University of Limoges, 87060 Limoges Cedex, France.
Mathilde Cheray
Affiliation:
Laboratory of “Homeostasie cellulaire et Pathologies”, University of Limoges, 87060 Limoges Cedex, France.
Fabrice Lalloue
Affiliation:
Laboratory of “Homeostasie cellulaire et Pathologies”, University of Limoges, 87060 Limoges Cedex, France.
Marie-Odile Jauberteau
Affiliation:
Laboratory of “Homeostasie cellulaire et Pathologies”, University of Limoges, 87060 Limoges Cedex, France.
Pierre Blondy
Affiliation:
XLIM Research Institute, Centre National de la Recherche Scientifique (CNRS), University of Limoges, 87060 Limoges Cedex, France.
*
Corresponding author: C. Dalmay Email: claire.dalmay@xlim.fr
Rights & Permissions [Opens in a new window]

Abstract

This paper presents an original biosensor chip allowing determination of intrinsic relative permittivity of biological cells at microwave frequencies. This sensor permits non-invasive cell identification and discrimination using an RF signal to probe intracellular medium of biological samples. Indeed, these sensors use an RF planar resonator that allows detection capabilities on less than 10 cells, thanks to the microscopic size of its sensitive area. Especially, measurements between 15 and 35 GHz show the ability label-free biosensors to differentiate two human cell types using their own electromagnetic characteristics. The real part of permittivity of cells changes from 20 to 48 for the nervous system cell types studied. The proposed biodetection method is detailed and we show how the accuracy and the repeatability of measurements have been improved to reach reproducible measurements.

Information

Type
Original Article
Copyright
Copyright © Cambridge University Press and the European Microwave Association 2010
Figure 0

Fig. 1. 3D view of the proposed micro biosensors: (a) using a support media during cell analysis and (b) with on chip cell culture.

Figure 1

Fig. 2. SEM photograph of 15.7 GHz RF biosensor.

Figure 2

Fig. 3. Equivalent RLC circuit of the unloaded biosensor and biosensor loaded by cells.

Figure 3

Fig. 4. Electric field distribution plot at the biosensor resonance frequency.

Figure 4

Table 1. Extracted RLC values of designed resonators.

Figure 5

Fig. 5. Simulated results of the biosensor response versus number of cells.

Figure 6

Fig. 6. Measured effect of different biological media on the biosensor frequency response.

Figure 7

Fig. 7. Fabricated 34.5 GHz biosensor photograph including micro culture chambers.

Figure 8

Fig. 8. Measured transmission response of the unloaded biosensor and sensor loaded with pure ficoll media.

Figure 9

Table 2. Evaluation of the global electrical parameters of ficoll and glial cells around 18 GHz at T = 20°C.

Figure 10

Fig. 9. Photograph of the biosensor loaded by U87-type glial cells embedded in dried ficoll matrix.

Figure 11

Fig. 10. Comparison between the measured transmission parameter of the unloaded sensor with the sensor loaded by pure ficoll and by ficoll containing glial cells.

Figure 12

Fig. 11. 3D view of the mesh used to simulate the cell effect on the biosensor response.

Figure 13

Fig. 12. Experimental protocol flow used for on chip cell culture.

Figure 14

Fig. 13. Comparison between measured RF sensor resonant frequency before and after glial cell adhesion.

Figure 15

Fig. 14. Photograph of the 15.7 GHz biosensor after the cell culture: glial cell locations are indicated by circles.

Figure 16

Fig. 15. 3D EM full wave modeling and experimental data fitting of glial cells interaction with the 16 GHz biosensor.

Figure 17

Fig. 16. Real part of permittivity versus frequency for glial cells and neuronal cells at 20°C.

Figure 18

Table 3. Evaluation of the real part of permittivity of glial and neuronal cells at 20°C.