Hostname: page-component-74656f9884-rngvg Total loading time: 0 Render date: 2026-11-05T14:31:52.462Z Has data issue: false hasContentIssue false

A novel morphing soft robot design to minimize deviations

Published online by Cambridge University Press:  10 October 2024

Varell Ferrandy
Affiliation:
The Hamlyn Centre, Mechanical Engineering, Imperial College London, London SW7 2AZ, UK
Arnau Garriga-Casanovas
Affiliation:
The Hamlyn Centre, Mechanical Engineering, Imperial College London, London SW7 2AZ, UK
Enrico Franco
Affiliation:
The Hamlyn Centre, Mechanical Engineering, Imperial College London, London SW7 2AZ, UK
Indrawanto
Affiliation:
Engineering Design and Production Research Group, Faculty of Mechanical and Aerospace Engineering - Institut Teknologi Bandung, Bandung, Indonesia
Ferdinando Rodriguez y Baena
Affiliation:
The Hamlyn Centre, Mechanical Engineering, Imperial College London, London SW7 2AZ, UK
Andi Isra Mahyuddin
Affiliation:
Dynamics and Control Research Group, Faculty of Mechanical and Aerospace Engineering - Institut Teknologi Bandung, Bandung, Indonesia
Vani Virdyawan*
Affiliation:
Engineering Design and Production Research Group, Faculty of Mechanical and Aerospace Engineering - Institut Teknologi Bandung, Bandung, Indonesia
*
Corresponding author: Vani Virdyawan; Email: vani.virdyawan@itb.ac.id
Rights & Permissions [Opens in a new window]

Abstract

Soft robotics is rapidly advancing, particularly in medical device applications. A particular miniaturized manipulator design that offers high dexterity, multiple degrees-of-freedom, and better lateral force rendering than competing designs, has great potential for minimally invasive surgery. However, it faces challenges such as the tendency to suddenly and unpredictably deviate in bending plane orientation at higher pressures. In this work, we identified the cause of this deviation as the buckling of the partition wall and proposed design alternatives along with their manufacturing process to address the problem without compromising the original design features. In both simulation and experiment, the novel design managed to achieve a better bending performance in terms of stiffness and reduced deviation of the bending plane. We also developed an artificial neural network-based inverse kinematics model to further improve the performance of the prototype during vectorization. This approach yielded mean absolute errors in orientation of the bending plane below $5^{\circ }$.

Information

Type
Research Article
Copyright
© The Author(s), 2024. Published by Cambridge University Press
Figure 0

Figure 1. Original design manipulator and cross-section dimensional specifications. $\gamma$ and $\theta$ depict the bending plane orientation angle and the bending angle of the manipulator when actuated.

Figure 1

Figure 2. Original design simulation results. (a) Bending plane orientation angle ($\gamma$) versus bending angle ($\theta$) of the manipulator with different types of winding. (b) The manipulator and its cross-section during pressurization at three different pressure values given to one of the chamber (depicted with red shading).

Figure 2

Figure 3. Proposed designs’ cross-section geometry and dimensional specifications. (a) Proposed design 1: angled walls. (b) Proposed design 2: zig-zag walls. (c) Proposed design 3: hollow diamond walls. (d) Proposed design 4: hollow circle walls. (e) Proposed design 5: hollow hybrid walls.

Figure 3

Figure 4. Comparison of the designs simulation results. (a) Bending plane orientation angle ($\gamma$) versus bending angle ($\theta$). (b) Bending angle ($\theta$) versus pressure. (c) Proposed design 2 manipulator and its cross-section during pressurization. Side view of the manipulator reveals deviating but a constant bending throughout pressurization. (d) Proposed design 3 manipulator and its cross-section during pressurization.

Figure 4

Table I. Relative comparison table

Figure 5

Figure 5. (a) Manufacturing process of the proposed design. (b) The three-part and two part mold of the proposed design. (c) Experimental setup.

Figure 6

Figure 6. Experimental results comparison of original and proposed design. (a) $\theta$ versus pressure for chamber 1 (top), chamber 2 (middle), and chamber 3 (bottom) (b) $\gamma$ versus $\theta$ for each chamber pressurization. (c) vectorization performance - $\gamma$ versus order of pressurized chamber.

Figure 7

Figure 7. Neural network experimental validation results. (a) Target versus actual measured $\theta$. (b) Target versus actual measured $\gamma$. (c) Error heat map of $\theta$. (d) Error heat map of $\gamma$. Error grids were generated through linear interpolation using the recorded data points (depicted as cross markers).