Real-time imaging of chromophore alignment in photorefractive polymer devices through multiphoton microscopy

Published online by Cambridge University Press:  19 May 2015

Brittany Lynn
Affiliation:
College of Optical Sciences, The University of Arizona, Tucson, Arizona, USA
Alexander Miles
Affiliation:
College of Optical Sciences, The University of Arizona, Tucson, Arizona, USA
Soroush Mehravar
Affiliation:
College of Optical Sciences, The University of Arizona, Tucson, Arizona, USA
Pierre-Alexandre Blanche*
Affiliation:
College of Optical Sciences, The University of Arizona, Tucson, Arizona, USA
Khanh Kieu
Affiliation:
College of Optical Sciences, The University of Arizona, Tucson, Arizona, USA
Robert A. Norwood
Affiliation:
College of Optical Sciences, The University of Arizona, Tucson, Arizona, USA
N. Peyghambarian
Affiliation:
College of Optical Sciences, The University of Arizona, Tucson, Arizona, USA
*
Address all correspondence to Pierre-Alexandre Blanche atpablanche@optics.arizona.edu

Abstract

A model with which to predict the effect of coplanar electrode geometry on diffraction uniformity in photorefractive polymer display devices was developed. Assumptions made in the standard use cases are no longer valid in the regions of extreme electric fields present in this type of device. Using electric-field induced second-harmonic generation through multiphoton microscopy, the physical response in regions of internal electric fields which fall outside the standard regimes of validity were probed. Adjustments to the standard model were made and the results of the new model corroborated through holographic four-wave mixing measurements.

Information

Type
Polymers/Soft Matter Research Letters
Copyright
Copyright © Materials Research Society 2015 
Figure 0

Figure 1. (a) Diagram of the electric field applied by the standard sandwich electrode configuration and the required use case for transmission hologram recording; (b) top view of the coplanar, interdigitated electrode configuration; (c) side view of the electric-field orientations and writing geometry for devices using coplanar electrodes.

Figure 1

Figure 2. Cross-section of the intensity [log10 (counts)] of the second-harmonic signal measured through the thickness of the polymer in the case of (a) hole-conducting PATPD, 2000 V applied bias and (b) non-conductive polystyrene, 4000 V applied bias. The grounded electrode is the right electrode imaged, located ~50 μm.

Figure 2

Figure 3. Intensity of the second-harmonic signal as a function of applied electric field. Low range fit is for applied electric fields <2500 V, while the high range fit is for the >2500 V range.

Figure 3

Figure 4. (a) Electric-field magnitude and (b) horizontal vector component applied by coplanar electrodes at 4000 V bias. Electrode width 10 μm, spacing between electrodes 100 μm, magnitude units in V/μm; (c) comparison of theoretical horizontal electric-field component at the electrode surface (z = 0) with the value obtained from EFISHG measurements at 4000 V applied bias.

Figure 4

Figure 5. Propagated reconstructed beam at 0°, 10°, and 20° degree tilt angle geometries of the recording beams in (a) electrode and (b) full beam scales.

Figure 5

Figure 6. Cross-sections of the measured incident and diffracted beam profiles taken (a) out of the plane of diffraction and (b) in the plane of diffraction for various tilt angles.