Hostname: page-component-74656f9884-npj9w Total loading time: 0 Render date: 2026-11-10T22:15:00.883Z Has data issue: false hasContentIssue false

Role of liquid driving on the clogging of constricted particle suspensions

Published online by Cambridge University Press:  16 December 2022

Mathieu Souzy*
Affiliation:
INRAE, Aix-Marseille Univ, UMR RECOVER, 13182 Aix-en-Provence, France Physics of Fluids, University of Twente, 7522NB Enschede, The Netherlands
Alvaro Marin*
Affiliation:
Physics of Fluids, University of Twente, 7522NB Enschede, The Netherlands
*
†Email addresses for correspondence: mathieu.souzy@inrae.fr, a.marin@utwente.nl
†Email addresses for correspondence: mathieu.souzy@inrae.fr, a.marin@utwente.nl

Abstract

Forcing dense suspensions of non-cohesive particles through constrictions might result in a continuous flow, an intermittent one, or indefinite interruption of flow, i.e. a clog. While one of the most important (and obvious) controlling parameters in such a system is the neck-to-particle size ratio, the role of the liquid driving method is not so straightforward. On the one hand, widespread volume-controlled systems such as syringe pumps result in pressure and local liquid velocity increases upon eventual clogs. On the other hand, pressure-controlled systems result in a decrease of the flow through the constriction when a clog is formed. The root of the question therefore lies in the role of interparticle liquid flow and hydrodynamic forces on both the formation and stability of an arch blocking the particle transport through a constriction. In this work, we study experimentally a suspension of non-cohesive particles flowing through a constricted channel (with neck-to-particle size ratio $3.03\leq D/d\leq 5.26$) in an intermittent fashion, in which they are most sensitive to parametric changes. Due to the stochastic nature of the intermittency, we make use of statistical distributions of arrest times and of discharged particles, and surprisingly, we find that the transport of non-cohesive suspensions through constrictions actually follows a ‘slower is faster’ principle under pressure-controlled driving: low imposed pressures yield intermittent non-persistent clogs, while high imposed pressures result in longer-lasting clogs, eventually becoming everlasting, and thus reducing the net particle transport rate.

Information

Type
JFM Papers
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2022. Published by Cambridge University Press.
Figure 0

Figure 1. Successive snapshots of a burst in a suspension of particles with diameter $d$ that flows intermittently through a constriction having neck width $1.1D$ and height $D=100\,\mathrm {\mu }{\rm m}$, with $D/d=3.03$. (a) Clog previous to a burst; (b) burst; and (c) clog after the burst. (a) and (c) are separated by approximately 10 ms.

Figure 1

Figure 2. Spatio-temporal diagrams at the constriction neck for $D/d=4.61$. (a) For volume-controlled driving, varying the flow rate $0.005< Q<2\,{\rm ml}\,{\rm min}^{-1}$ does not affect the intermittent flow of particles. (b) For pressure-controlled driving, increasing $P$ induces fewer particles escaping (dark) before a clog forms, and longer arrest times (in grey). The red-framed diagrams highlight two similar $Re$ configurations (see also table 1).

Figure 2

Table 1. Values of $Re$, $\langle s\rangle$ and $\alpha$ for various neck-to-particle size ratios, for volume-controlled and pressure-controlled driving. Grey areas indicate non-investigated parameter values. NA indicates non-intermittent configurations for which we could not estimate the corresponding values: $^{a}$continuous particle flow, and $^{b}$everlasting clog. Red frames highlight two similar Reynolds number configurations (see also the corresponding spatio-temporal diagrams in figure 2).

Figure 3

Figure 3. Average number $\langle s\rangle$ of escapees per burst, for various neck-to-particle size ratios $D/d$. (a) In the volume-driven configuration, $\langle s\rangle$ remains almost constant when varying the flow rate $Q$. For $D/d=3.03$, no intermittency is observed for $Re > 0.478$ ($Q > 0.1\, {\rm ml}\,{\rm min}^{-1}$) as any developed clog is permanent and everlasting. (b) In the pressure-driven configuration, $\langle s\rangle$ decreases when increasing the imposed pressure $P$. For $D/d=5.26$, the flow of particles is continuous for $Re\leq 0.025$ ($P\leq 48$ kPa).

Figure 4

Figure 4. Distribution of the arrest time lapses normalized by the Stokes time $T/\tau$ for $D/d=3.03$ with pressure-controlled driving. The lines correspond to the best power-law fits with their exponent $\alpha$, as given by the Clauset–Shalizi–Newman method (Clauset et al.2009).

Figure 5

Figure 5. Exponent $\alpha$ of the power-law tail of the time lapse distribution $P(T/\tau )\propto (T/\tau )^{-\alpha }$. (a) In the volume-driven configuration, $\alpha$ remains almost constant when varying the flow rate $Q$. For $D/d=3.03$, no value of $\alpha$ could be defined for $Re > 0.478$ ($Q > 0.1\, {\rm ml}\,{\rm min}^{-1}$) as there is no intermittency. (b) In the pressure-driven configuration, $\alpha$ exhibits a power-law decrease $\alpha \propto Re^{-0.076}$. For $D/d=5.26$, no value of $\alpha$ could be defined for $Re\leq 0.025$ ($P\leq 48$ kPa) as there is a continuous flow of particles. The explicit values of $\alpha$ can be found in table 1.

Figure 6

Figure 6. Distribution of the burst time $P(T_{flow}/\tau )$ for pressure-controlled driving for $D/d=4.61$. The lines correspond to the expected exponential trend. The difference in the slopes of the exponential fits indicates that the average number of escapees $\langle s\rangle$ is quantitatively different between these two configurations.

Figure 7

Figure 7. For volume-controlled driving: (a) particle velocity at the neck (measured using PIV); and (b) clogging events ($1\rightarrow$ clog, $0\rightarrow$ particle burst) for $D/d=4.61$, $Re=0.031$, $\left \langle s\right \rangle =46\,000$ and $\alpha =1.83$. For pressure-controlled driving: (c) particle velocity at the neck; and (d) clogging events for $D/d=4.61$, $Re=0.063$, $\left \langle s\right \rangle =15\,000$ and $\alpha =1.85$. Note that velocity can be measured only during particle bursts.

Figure 8

Figure 8. For volume-controlled driving: (a) flow rate measurement performed upstream of the constriction; and (b) clogging events ($1\rightarrow$ clog, $0\rightarrow$ particle burst), for neck-to-particle ratio $D/d=3.03$ and Reynolds $Re=0.17$.

Figure 9

Figure 9. Average particle flow rate during a burst, (number of particles per second) taking into account only the periods when the particles are continuously flowing. Horizontal error bars indicate the standard deviation of the flowing particle velocity measurement $U$, and vertical error bars are computed using the standard deviation of the number of escapees.