Bragg peak characteristics of proton beams within therapeutic energy range and the comparison of stopping power using the GATE Monte Carlo simulation and the NIST data

Published online by Cambridge University Press:  31 July 2019

Shiva Zarifi
Affiliation:
Department of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran
Hadi Taleshi Ahangari*
Affiliation:
Department of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran
Sayyed Bijan Jia
Affiliation:
Department of Physics, University of Bojnord, Bojnord, Iran
Mohammad Ali Tajik-Mansoury
Affiliation:
Department of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran
Milad Najafzadeh
Affiliation:
Department of Radiology, Faculty of Para-Medicine, Hormozgan University of Medical Sciences, Bandare-Abbas, Iran
Milad Peer Firouzjaei
Affiliation:
Department of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran
*
Author for correspondence: Hadi Taleshi Ahangari, Department of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran. Tel: +98 9127101772. E-mail: Taleshi@semums.ac.ir
Rights & Permissions [Opens in a new window]

Abstract

Purpose:

To examine detail depth dose characteristics of ideal proton beams using the GATE Monte Carlo technique.

Methods:

In this study, in order to improve simulation efficiency, we used pencil beam geometry instead of parallel broad-field geometry. Depth dose distributions for beam energies from 5 to 250 MeV in a water phantom were obtained. This study used parameters named Rpeak, R90, R80, R73, R50, full width at half maximum (FWHM), width of 80–20% distal fall-off (W(80–20)) and peak-to-entrance ratio to represent Bragg peak characteristics. The obtained energy–range relationships were fitted into third-order polynomial formulae. The present study also used the GATE Monte Carlo code to calculate the stopping power of proton pencil beams in a water cubic phantom and compared results with the National Institute of Standards and Technology (NIST) standard reference database.

Results:

The study results revealed deeper penetration, broader FWHM and distal fall-off and decreased peak-to-entrance dose ratio with increasing beam energy. Study results for monoenergetic proton beams showed that R73 can be a good indicator to characterise a range of incident beams. These also suggest FWHM is more sensitive than W(80–20) distal fall-off in finding initial energy spread. Furthermore, the difference between the obtained stopping power from simulation and NIST data almost in all energies was lower than 1%.

Conclusion:

Detail depth dose characteristics for monoenergetic proton beams within therapeutic energy ranges were reported. These results can serve as a good reference for clinical practitioners in their daily practice.

Information

Type
Original Article
Copyright
© Cambridge University Press 2019
Figure 0

Figure 1. Schematic image of phantom geometry and incident beams.

Figure 1

Figure 2. Pristine depth–dose profiles for proton beams with an energy range of 5–250 MeV. A zoom of the depth–dose curve for 0–50 MeV is shown for better understanding.

Figure 2

Figure 3. Diagrams of 2D dose distribution for a monoenergetic proton pencil beam in water.

Figure 3

Figure 4. (a) Range of proton beams as a function of energy defined at different distal dose levels, that is, Rx. (b) Deviations of characteristic beam range parameters from the NIST data.

Figure 4

Figure 5. Least squares value as a function of Rx. (NIST values used as reference to calculate least squares).

Figure 5

Table 1. Third-order formulae for fitting GATE-simulated data of the characteristic range parameters to incident beam energy

Figure 6

Figure 6. FWHM and W(80–20) values of depth–dose profiles as a function of beam energies.

Figure 7

Figure 7. PER in terms of incident energy.

Figure 8

Table 2. Stopping power of protons in water and comparison with NIST, along with relative percentage differences

Figure 9

Figure 8. Proton stopping power as a function of proton energy.

Figure 10

Figure 9. Absorbed depth–dose profile for a 150 MeV proton pencil beam in water phantom (green curve, left-hand axis) and its associated relative statistical uncertainty (purple curve, right-hand axis).

Figure 11

Table 3. Comparison between the difference obtained for the proton range with simulation and NIST data and statistical uncertainty