A cone beam CT-based study on fiducial seed migration and planning target volume margin in prostate radiotherapy

Published online by Cambridge University Press:  21 November 2019

Divya K. Thuruthiyil*
Affiliation:
Department of Radiotherapy, United Lincolnshire Hospitals NHS Trust, Lincoln, UK
Martin Cawley
Affiliation:
Department of Radiotherapy, United Lincolnshire Hospitals NHS Trust, Lincoln, UK
Mohamed Metwaly
Affiliation:
Department of Radiotherapy, United Lincolnshire Hospitals NHS Trust, Lincoln, UK
*
Author for correspondence: Divya K. Thuruthiyil, Department of Radiotherapy Physics, United Lincolnshire Hospitals NHS Trust, Lincoln LN2 5QY, UK. E-mail: divya.kizhakkethuruthiyil@ulh.nhs.uk
Rights & Permissions [Opens in a new window]

Abstract

Aim:

This study attempts to investigate fiducial marker (FM) migration and calculate the prostate planning target volume (PTV) margin considering the setup errors after translation corrections alone (T) and translation plus rotational corrections (T+R) and anatomy variation with respect to the corrected fiducial position, analysed on cone beam computed tomography (CBCT) images.

Methods and materials:

CBCT images from 25 patients are analysed for FM movements, setup error and anatomy variation with respect to the seed match positions. Systematic and random components of setup error and prostate movements are used to calculate the PTV margin for CBCT-based FM localisation in two scenarios, translation corrections only and translation plus rotational correction. MTNW887825 soft tissue gold markers (Civco, Orange City, FL, USA) were used with the department-specific immobilisation system and rectal and bladder filling protocols.

Results:

The average directional inter-marker distance variation is −0·05 ± 0·90 mm. The systematic setup errors for T+R are 0·40, 0·63 and 0·80 mm in right–left (RL), anterior–posterior (AP) and superior–inferior (SI), respectively. The corresponding values for T only are 0·54, 0·69 and 0·90 mm. The systematic prostate movement from T+R corrected FM positions are 0·65, 1·27 and 1·32 mm in the RL, AP and SI directions.

Findings:

Minimal FM movements are noted from the study. The PTV margins to incorporate the daily T+R corrected setup error and prostate deformation are found to be 2·5, 4·5 and 5·2 mm in the RL, AP and SI directions, respectively. The corresponding margins for T only corrected scenario are found to be 2·8, 4·8 and 5·7 mm.

Information

Type
Original Article
Copyright
© Cambridge University Press 2019
Figure 0

Figure 1. Diagrammatic representation of the methods used in the study.

Figure 1

Figure 2. ‘Inter marker distance’ represents the magnitude of the displacement vector between two fiducial markers.

Figure 2

Table 1. The statistical parameters for IMD variation study method 1—considering the RL, AP and SI components separately and as a whole

Figure 3

Table 2. The statistical parameters of residual error after seed match and setup correction. ∑setup and σsetup represent the systematic and random components of setup error after corrections

Figure 4

Table 3. The statistical parameters of anatomy variation. ∑anatomy and σanatomy represent the systematic and random components of anatomy variation with respect to setup corrected FM positions

Figure 5

Table 4. PTV margins from residual setup errors and anatomy variation. Setup correction follows two scenarios, translation+rotation correction and translation correction alone

Figure 6

Figure 3. IMD variation in each patient. Blue points represent average in each patient and error bars represent the SD. Y-axis—IMD variation in millimeter.

Supplementary material: File

Thuruthiyil et al. supplementary material

Figures S1-S4 and Tables S1-S2

Download Thuruthiyil et al. supplementary material(File)
File 29.8 MB