Hostname: page-component-74656f9884-j7cmm Total loading time: 0 Render date: 2026-11-10T03:12:51.237Z Has data issue: false hasContentIssue false

Analysis of liquid column atomization by annular dual-nozzle gas jet flow

Published online by Cambridge University Press:  13 June 2022

Daehyun Choi
Affiliation:
Department of Mechanical Engineering, Seoul National University, Seoul 08826, Korea
Jungwon Byun
Affiliation:
Global Technology Center, Samsung Electronics, Suwon 16677, Korea
Hyungmin Park*
Affiliation:
Department of Mechanical Engineering, Seoul National University, Seoul 08826, Korea Institute of Advanced Machines and Design, Seoul National University, Seoul 08826, Korea
*
†Email address for correspondence: hminpark@snu.ac.kr

Abstract

The atomization of a water column by a gas jet flow (Reynolds number $\sim O(10^{4}\unicode{x2013}10^{5})$) issued from a two-stage annular nozzle is investigated experimentally. Varying the nozzle geometry, the momentum flux ratio of the upper and lower jets, and the water flow rate, we measure the processes of atomization with high-speed imaging, analysed analytically into four regimes. In the bulk atomization regime, the atomization is driven by the lower jet, but it is forced to occur earlier by the stronger upper jet before the water column reaches the lower jet in the droplet atomization regime. Interestingly, the size of the atomized droplets remains unaffected by the momentum flux ratio of upper to lower jets. The atomization process is governed by the Rayleigh–Taylor instability, by which the estimated droplet size agrees well with the measurement. In the backflow regime, a strong reverse flow is induced to force a substantial portion of atomized droplets to be drawn backward to the nozzle; a floating liquid column regime is captured transitionally, i.e. the column stagnates near the lower nozzle when the water flow rate is very low. To understand the mechanisms of each regime, the single-phase jet flow is measured separately using particle image velocimetry, and implemented into the control volume analysis with which we predicted analytically and validated the conditions for the occurrence of each regime. It is found that the acceleration of gas flow (velocity gradient) experienced by the falling water is the key parameter to drive the atomization.

Information

Type
JFM Papers
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright
© The Author(s), 2022. Published by Cambridge University Press
Figure 0

Figure 1. Schematic of the flow-assisted atomization of a liquid column: (a) conventional single-nozzle configuration; (b) dual-nozzle configuration considered in the present study. In panel (b), the droplet and bulk atomization (distinguished by the dashed centreline) can occur in the same nozzle configuration by varying the operating conditions.

Figure 1

Figure 2. (a) Schematic of the experimental set-up for dual-nozzle gas atomization. (b) Detailed geometry of the dual-nozzle atomizer (cross-section at the $z = 0$ plane).

Figure 2

Table 1. Nozzle geometry and gas–liquid flow conditions tested in the present study, where S indicates shadowgraphy, and P indicates particle image velocimetry.

Figure 3

Figure 3. Representative instantaneous image to show the disintegration process of the falling water column by dual gas jets, with $\theta _{2}=40^{\circ }$, $m_{12} = 0.27$, $m_{L2} = 0.051$, $We_{eff1} = 7.4$, $We_{eff2} = 112$, $Re_{1} = 6.2 \times 10^{4}$ and $Re_{2} =1.1 \times 10^{5}$.

Figure 4

Figure 4. Instantaneous flow images showing the disintegration process of the falling water column by the gas jet depending on the momentum flux ratio ($m_{12}$): (a) $m_{12} = 0$; (b) $m_{12} = 0.17$; (c) $m_{12} = 0.27$ ($We_{eff2} = 110$, $Re_{2} = 1.1 \times 10^{5}$); (d) $m_{12} = 0.27$ ($We_{eff2} = 210$, $Re_{2} = 1.5 \times 10^{5}$). For all cases, $\theta _{2} = 40^{\circ }$ and $m_{L2} = 0.051$, except in (d), where $m_{L2} = 0.027$. See also supplementary movie 1 for the details.

Figure 5

Figure 5. Time-averaged gas-phase flow field with (a–c) $m_{12}=0$, (d–f) $m_{12}=0.11$. (a,d) Vertical velocity ($\bar {u}_{y}/u_{2}$); (b,e) horizontal r.m.s. velocity ($u'_{x,rms}/u_{2}$); (c, f) vertical r.m.s. velocity ($u'_{y,rms}/u_{2}$). Here, $Re_{2} = 1.09 \times 10^{5}$ and $\theta _{2} = 20^{\circ }$. In the region near the jet exit ($0.2<|x/D_{2}|<0.8$), vectors with low fidelity (where the number of valid vectors is below a specific fraction (${\sim }40\,\%$) of the total number of vectors, determined according to the set-up) are masked to avoid misrepresentation of the flow.

Figure 6

Figure 6. Time-averaged gas-phase flow field with (a–c) $m_{12}=0$, (d–f) $m_{12}=0.11$. (a,d) Vertical velocity ($\bar {u}_{y}/u_{2}$); (b,e) horizontal r.m.s. velocity ($u'_{x,rms}/u_{2}$); (c, f) vertical r.m.s. velocity ($u'_{y,rms}/u_{2}$). Here, $Re_{2} = 1.09 \times 10^{5}$ and $\theta _{2} = 40^{\circ }$. In the region near the jet exit ($0.2<|x/D_{2}|<0.8$), vectors with low fidelity (where the number of valid vectors is below a specific fraction (${\sim }70\,\%$) of the total number of vectors, determined according to the set-up) are masked to avoid misrepresentation of the flow.

Figure 7

Figure 7. (a–c) Time-averaged vertical velocity profiles ($\bar {u}_{y}/u_{2}$), (d–f) horizontal r.m.s. velocity fluctuation profiles ($u'_{x,rms}/u_{2}$), and (g–i) vertical r.m.s. velocity fluctuation profiles ($u'_{y,rms}/u_{2}$) along the centreline ($x = 0$), where: (a,d,g) $\theta _{2} =20^{\circ }$; (b,e,h) $40^{\circ }$; (c,f ,i) $60^{\circ }$. Symbols: $\circ$ indicates $m_{12} = 0$; $\times$ indicates $m_{12} = 0.067$; $\vartriangle$ indicates $m_{12} = 0.11$; $+$ indicates $m_{12} = 0.14$; $\lozenge$ indicates $m_{12} = 0.17$. For all cases, $We_{eff2} = 83\unicode{x2013}747$ and $Re_{2} = 1.9 \times 10^{5}$. The arrows denote the direction of increasing $m_{12}$.

Figure 8

Figure 8. Sequential atomization process of the falling water column with (a) $\theta _{2} = 20^{\circ }$; (b) $\theta _{2} = 40^{\circ }$; (c) $\theta _{2} = 60^{\circ }$. The time difference between two instants is $1.4$ ms in (a,b), and $0.45$ ms in (c). For all cases, $m_{12} = 0.11$, $We_{eff2} = 28\unicode{x2013}252$, $Re_{2} = 1.1 \times 10^{5}$, and $m_{L2} = 0.051$.

Figure 9

Figure 9. Representative instantaneous flows showing the atomization process of the falling water column depending on (a,b) $m_{L2} = 0.0056$, (c) $m_{L2} = 0.051$, (d) $m_{L2} = 0.14$. For all cases, $We_{eff2} = 112$, $Re_{2} = 1.1 \times 10^{5}$ and $\theta _2 = 40^{\circ }$. See also supplementary movie 2.

Figure 10

Figure 10. Sauter mean diameter ($d_{32}$) of the atomized droplets depending on (a) momentum flux ratio between the two gas jets ($m_{12}$), (b) angle of the lower nozzle ($\theta _2$), and (c) momentum flux ratio of the liquid to the lower gas jet ($m_{L2}$). For (a,b): closed symbols use $m_{L2} = 0.051$, $We_{eff2} = 28\unicode{x2013}252$, $Re_{2} = 1.1 \times 10^{5}$; open symbols use $m_{L2} = 0.027$, $We_{eff2} = 52\unicode{x2013}468$, $Re_{2} = 1.5 \times 10^{5}$. For (c), $\theta _{2} = 40^{\circ }$, $m_{12} = 0$, $We_{eff2} = 112$ and $Re_{2} = 1.1 \times 10^{5}$.

Figure 11

Figure 11. Variations of the droplet diameter ($d_{32}$) normalized by the liquid exit size depending on the effective Weber number. The dashed line corresponds to the curve $d_{32}/D_{L} \sim We_{eff}^{-0.7}$.

Figure 12

Figure 12. The probability distribution function of the droplet size depending on $We_{eff2} = 45$ ($\circ$), $72$ ($\times$), $114$ ($\vartriangle$), and $210$ ($+$), when $m_{12} = 0$. The symbol $\lozenge$ corresponds to the dual-nozzle case ($We_{eff1} = 210$, $We_{eff2} = 210$ and $m_{12} = 0.27$). For all cases, $\theta _{2} = 40^{\circ }$. Inset shows the p.d.f. for single ($+$) and dual ($\lozenge$) nozzle in log-log scale, and the solid and dashed lines denote the fitted log-normal curve for single and dual nozzles, respectively, while the dotted line denotes the gamma distribution.

Figure 13

Figure 13. Atomization regime map according to the momentum flux ratio between two gas jets ($m_{12}$), the angle of the lower nozzle ($\theta _2$), and the mass flux ratio of the liquid jet ($m_{L2}$). Representative snapshots visualizing the instantaneous atomization process are shown together, being matched with each symbol in the regime map. Here, the coordinate $s$ is set to the line $m_{12} = m_{L2}$.

Figure 14

Figure 14. Two-dimensional regime maps projected on (a) the $m_{12}$–$\sin \theta _2$ plane, (b) the $(m_{12} + m_{L2})$–$\sin \theta _2$ plane, and (c) the $m_{12}$–$m_{L2}$ plane, from the data in the three-dimensional map (figure 13). The dashed lines in (a,b,c) correspond to equations (4.7), (4.9) and (4.12), respectively.

Figure 15

Figure 15. Schematic for the control volume analysis to analyse the backflow ($C_1$, dotted red line) and the velocity gradient ($C_2$, solid blue line). Note that the control volume is assumed to be axisymmetric against the vertical centreline.

Figure 16

Figure 16. (a) Condition for the backflow regime in terms of momentum flux of the upper jet ($u_{1}^{2}A_{1}$) and the horizontal momentum flux of the lower jet ($u_{2}^{2}\sin {\theta _2}\,A_{2}$). The dashed line corresponds to (4.7) with $B = 0.1$. (b) Comparison of velocity gradient (${\rm d}\bar {u}_{y}^{*}/{{\rm d} y}^{*}$) with the analytical estimation ($\Delta \hat {v}^{*}$).

Figure 17

Figure 17. (a–c) Instantaneous atomization images showing the disintegration process of the liquid column by the gas jet. Rectangular boxes indicate the measurement area in which the Rayleigh–Taylor instability occurs. (d–f) Results of pattern identification (thick circles) corresponding to the Rayleigh–Taylor length scale: (a,d) $\theta _{2} = 20^{\circ }$; (b,e) $\theta _{2} = 40^{\circ }$; (c, f) $\theta _{2} = 60^{\circ }$. Here, $m_{L2} = 0.051$, $We_{eff2} = 28\unicode{x2013}252$ and $Re_{2} = 1.1 \times 10^{5}$.

Figure 18

Figure 18. (a) Comparison between theoretical estimation on the length scale of the Rayleigh–Taylor instability ($\lambda _{RT,est}$) and the length scale measured experimentally ($\lambda _{RT,exp}$). Here, $m_{12} = 0\unicode{x2013}0.27$, $Re_{2} = 0.69\unicode{x2013}1.1 \times 10^{5}$ and $m_{L2} = 0.051\unicode{x2013}0.13$. (b) Representative atomization visualizations showing the Rayleigh–Taylor cells (indicated by arrows) corresponding to each case (symbols from (a) are noted at bottom right in each image).

Figure 19

Figure 19. Ratio of the Sauter mean diameter ($d_{32}$) to (a) $\lambda _{KH,est}$ and (b) $\lambda _{RT,est}$, depending on the flow regime.

Figure 20

Figure 20. Instantaneous atomization images showing the pre-atomized water column depending on the flux of upper jet ($u_{2} = 0$): (a) $M_{L1} = 0.2$; (b) $0.12$; (c) $0.095$; (d) $0.078$; (e) $0.067$. Here, $We_{eff1} = 4.6\unicode{x2013}13.6$ and $Re_{1} = 4.9\unicode{x2013}8.5 \times 10^{4}$.

Choi et al. supplementay movie 1

See pdf file for movie caption

Download Choi et al. supplementay movie 1(Video)
Video 1.4 MB

Choi et al. supplementary movie 2

See pdf file for movie caption

Download Choi et al. supplementary movie 2(Video)
Video 1.3 MB

Choi et al. supplementary movie 3

See pdf file for movie caption

Download Choi et al. supplementary movie 3(Video)
Video 2.5 MB
Supplementary material: PDF

Choi et al. supplementary material

Captions for movies 1-3

Download Choi et al. supplementary material(PDF)
PDF 1.4 MB