Hostname: page-component-74656f9884-c52kr Total loading time: 0 Render date: 2026-11-07T09:40:04.989Z Has data issue: false hasContentIssue false

A high-accuracy hollowness inspection system with sensor fusion of ultra-wide-band radar and depth camera

Published online by Cambridge University Press:  23 December 2022

Haoran Kang
Affiliation:
Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen, Guangdong Province 518055, People’s Republic of China
Wentao Zhang
Affiliation:
Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen, Guangdong Province 518055, People’s Republic of China
Yangtao Ge
Affiliation:
Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen, Guangdong Province 518055, People’s Republic of China
Haiou Liao
Affiliation:
Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen, Guangdong Province 518055, People’s Republic of China
Bangzhen Huang
Affiliation:
Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen, Guangdong Province 518055, People’s Republic of China
Jing Wu*
Affiliation:
Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen, Guangdong Province 518055, People’s Republic of China
Rui-Jun Yan
Affiliation:
Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen, Guangdong Province 518055, People’s Republic of China
I-Ming Chen
Affiliation:
School of Mechanical and Aerospace Engineering, Nanyang Technological University, 639798, Singapore
*
*Corresponding author. E-mail: wuj@sustech.edu.cn
Rights & Permissions [Opens in a new window]

Abstract

With the dangerous and troublesome nature of hollow defects inside building structures, hollowness inspection has always been a challenge in the field of construction quality assessment. Several methods have been proposed for inspecting hollowness inside concrete structures. These methods have shown great advantages compared to manual inspection but still lack autonomy and have several limitations. In this paper, we propose a range-point migration-based non-contact hollowness inspection system with sensor fusion of ultra-wide-band radar and laser-based depth camera to extract both outer surface and inner hollowness information accurately and efficiently. The simulation result evaluates the performance of the system based on the original range-point migration algorithm, and our proposed one and the result of our system show great competitiveness. Several simulation experiments of structures that are very common in reality are carried out to draw more convincing conclusions about the system. At the same time, a set of laboratory-made concrete components were used as experimental objects for the robotic system. Although still accompanied by some problems, these experiments demonstrate the availability of an automated hollow-core detection system.

Information

Type
Research Article
Copyright
© The Author(s), 2022. Published by Cambridge University Press
Figure 0

Figure 1. The system setup of the inspection robot. (a) The schematic of the robot system setup. (b) The experiment setup of hollow inspection system.

Figure 1

Figure 2. The total workflow of the quality inspection robot system.

Figure 2

Figure 3. The comparison of outer surface point extraction procedure through original RPM algorithm with different antenna used.

Figure 3

Figure 4. The schematic diagram of the inner candidate curve and the outer surface points used in RPM algorithm. For targets buried inside dielectric structures, candidate travel paths should be calculated with refraction considered.

Figure 4

Figure 5. Schematic diagram of the overall workflow, the outer and inner data acquisition are decoupled.

Figure 5

Table I. Simulation environment parameters.

Figure 6

Figure 6. The outer surface points extracted through both methods. The gray curved surface is the real front outer surface. The blue points are results of both methods.

Figure 7

Figure 7. The inner target surface points extracted through both method. The gray curved surface is the real front outer surface; the blue plane is the real inner target front surface. The red points are results of both methods, which are calculated with the same outer surface data shown in Fig. 6(b). The outer surface normals are calculated in different ways.

Figure 8

Figure 8. The dielectric component with hollow defect buried inside. (a). The overall view of the component. (b). The reshaping procedure of the front surface of component.

Figure 9

Figure 9. Illustration of the impact of false normal to potential target point. ${n^g}$ and ${n^{g{\prime}}}$ represent real and false normal, respectively, the potential point calculated by ${n^{g{\prime}}}$ shows a noticeable shift from the real one ${p^d}$.

Figure 10

Table II. Evaluation of simulation results with $\tau = 1$.

Figure 11

Figure 10. Ratio $r$ of valid result points with $\tau $ from 1 to 1.6.

Figure 12

Table III. Commonly used structures and simulation experiments results.

Figure 13

Figure 11. The simulation result of the original method against the stair structure.

Figure 14

Figure 12. The commonly used structures in real building scenarios.

Figure 15

Table IV. Commonly used structures and simulation experiments results.

Figure 16

Figure 13. The schematic diagram of used concrete structure.

Figure 17

Table V. Autonomous NDT robot system parameters.

Figure 18

Figure 14. The schematic diagram of the experiment setup.

Figure 19

Figure 15. The result of the experiment, in which those blue points represent the imaging result. The experiment result shows the hollow with complex shape is difficult to imaging.

Figure 20

Figure 16. The comparison of signals reflected from the concrete structure and the floor. The true position of the tiles inside the floor remains unknown so there is no experiment produced on it.