Hostname: page-component-74656f9884-8rzl6 Total loading time: 0 Render date: 2026-11-06T07:37:58.479Z Has data issue: false hasContentIssue false

A Comparison of Paramedic First Pass Endotracheal Intubation Success Rate of the VividTrac VT-A 100, GlideScope Ranger, and Direct Laryngoscopy Under Simulated Prehospital Cervical Spinal Immobilization Conditions in a Cadaveric Model

Published online by Cambridge University Press:  15 August 2017

Ryan Hodnick*
Affiliation:
Santa Fe Fire Department, Santa Fe, New Mexico USA Santa Fe County Fire EMS, Santa Fe, New Mexico USA Arteria Fire Department, Artesia, New Mexico USA Carlsbad Fire Department, Carlsbad, New Mexico USA TriState CareFlight, Bullhead City, Arizona USA MedFlight, Albuquerque, New Mexico USA University of Nevada Department of Emergency Medicine, Las Vegas, Nevada USA
Tony Zitek
Affiliation:
University of Nevada Department of Emergency Medicine, Las Vegas, Nevada USA
Kellen Galster
Affiliation:
University of Nevada Department of Emergency Medicine, Las Vegas, Nevada USA
Stephen Johnson
Affiliation:
Medic West Ambulance, Las Vegas, Nevada USA
Bryan Bledsoe
Affiliation:
University of Nevada Department of Emergency Medicine, Las Vegas, Nevada USA Medic West Ambulance, Las Vegas, Nevada USA
Daniel Ebbs
Affiliation:
A.T. Still School of Osteopathic Medicine, Mesa, Arizona USA
*
Correspondence: Ryan Hodnick, DO, NREMT-P University of Nevada School of Medicine Department of Emergency Medicine 901 Rancho Lane, Suite 135 Las Vegas, Nevada 89106 USA E-mail: lasvegas.em@gmail.com
Rights & Permissions [Opens in a new window]

Abstract

Objective

The primary goal of this study was to compare paramedic first pass success rate between two different video laryngoscopes and direct laryngoscopy (DL) under simulated prehospital conditions in a cadaveric model.

Methods

This was a non-randomized, group-controlled trial in which five non-embalmed, non-frozen cadavers were intubated under prehospital spinal immobilization conditions using DL and with both the GlideScope Ranger (GL; Verathon Inc, Bothell, Washington USA) and the VividTrac VT-A100 (VT; Vivid Medical, Palo Alto, California USA). Participants had to intubate each cadaver with each of the three devices (DL, GL, or VT) in a randomly assigned order. Paramedics were given 31 seconds for an intubation attempt and a maximum of three attempts per device to successfully intubate each cadaver. Confirmation of successful endotracheal intubation (ETI) was confirmed by one of the six on-site physicians.

Results

Successful ETI within three attempts across all devices occurred 99.5% of the time overall and individually 98.5% of the time for VT, 100.0% of the time for GL, and 100.0% of the time for DL. First pass success overall was 64.4%. Individually, first pass success was 60.0% for VT, 68.8% for GL, and 64.5% for DL. A chi-square test revealed no statistically significant difference amongst the three devices for first pass success rates (P=.583). Average time to successful intubation was 42.2 seconds for VT, 38.0 seconds for GL, and 33.7 for seconds for DL. The average number of intubation attempts for each device were as follows: 1.48 for VT, 1.40 for GL, and 1.42 for DL.

Conclusion

The was no statistically significant difference in first pass or overall successful ETI rates between DL and video laryngoscopy (VL) with either the GL or VT (adult).

HodnickR , ZitekT , GalsterK , JohnsonS , BledsoeB , EbbsD . A Comparison of Paramedic First Pass Endotracheal Intubation Success Rate of the VividTrac VT-A 100, GlideScope Ranger, and Direct Laryngoscopy Under Simulated Prehospital Cervical Spinal Immobilization Conditions in a Cadaveric Model. Prehosp Disaster Med. 2017;32(6):621–624.

Information

Type
Original Research
Copyright
© World Association for Disaster and Emergency Medicine 2017