Hostname: page-component-6898cfcb55-kwdml Total loading time: 0 Render date: 2026-11-11T12:21:46.882Z Has data issue: false hasContentIssue false

Turbulent Rayleigh–Bénard convection with bubbles attached to the plate

Published online by Cambridge University Press:  25 July 2022

Hao-Ran Liu
Affiliation:
Physics of Fluids Group, Max Planck Center Twente for Complex Fluid Dynamics and J. M. Burgers Centre for Fluid Dynamics, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
Kai Leong Chong
Affiliation:
Shanghai Key Laboratory of Mechanics in Energy Engineering, Shanghai Institute of Applied Mathematics and Mechanics, School of Mechanics and Engineering Science, Shanghai University, Shanghai 200072, PR China
Rui Yang
Affiliation:
Physics of Fluids Group, Max Planck Center Twente for Complex Fluid Dynamics and J. M. Burgers Centre for Fluid Dynamics, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
Roberto Verzicco
Affiliation:
Physics of Fluids Group, Max Planck Center Twente for Complex Fluid Dynamics and J. M. Burgers Centre for Fluid Dynamics, University of Twente, P.O. Box 217, 7500 AE Enschede, The NetherlandsDipartimento di Ingegneria Industriale, University of Rome ‘Tor Vergata’, Via del Politecnico 1, Roma 00133, ItalyGran Sasso Science Institute, Viale F. Crispi, 7, 67100 L'Aquila, Italy
Detlef Lohse*
Affiliation:
Physics of Fluids Group, Max Planck Center Twente for Complex Fluid Dynamics and J. M. Burgers Centre for Fluid Dynamics, University of Twente, P.O. Box 217, 7500 AE Enschede, The NetherlandsMax Planck Institute for Dynamics and Self-Organization, Am Fassberg 17, 37077 Göttingen, Germany
*
†Email address for correspondence: d.lohse@utwente.nl

Abstract

We numerically investigate turbulent Rayleigh–Bénard convection with gas bubbles attached to the hot plate, mimicking a core feature in electrolysis, catalysis or boiling. The existence of bubbles on the plate reduces the global heat transfer due to the much lower thermal conductivity of gases as compared with liquids and changes the structure of the boundary layers. The numerical simulations are performed in three dimensions at Prandtl number $\mbox{Pr}=4.38$ (water) and Rayleigh number $10^7\leqslant \mbox{Ra}\leqslant 10^8$. For simplicity, we assume the bubbles to be equally sized and having pinned contact lines. We vary the total gas-covered area fraction $0.18 \leqslant S_0 \leqslant 0.62$, the relative bubble height $0.02\leqslant h/H \leqslant 0.05$ (where $H$ is the height of the Rayleigh–Bénard cell), the bubble number $40 \leqslant n \leqslant 144$ and their spatial distribution. In all cases, asymmetric temperature profiles are observed, which we quantitatively explain based on the heat flux conservation at each horizontal section. We further propose the idea of using an equivalent single-phase set-up to mimic the system with attached bubbles. Based on this equivalence, we can calculate the heat transfer. Without introducing any free parameter, the predictions for the Nusselt number, the upper and lower thermal boundary layer thicknesses and the mean centre temperature agree well with the numerical results. Finally, our predictions also work for the cases with much larger $\mbox{Pr}$ (e.g. $400$), which indicates that our results can also be applied to predict the mass transfer in water electrolysis with bubbles attached to the electrode surface or in catalysis.

Information

Type
JFM Papers
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2022. Published by Cambridge University Press
Figure 0

Table 1.Material and geometrical parameters controlling the flow and their typical values (upper part) and all resulting dimensionless parameters (lower part). Here, $U=\sqrt {\beta _l g H \varDelta }$ is the free-fall velocity. The index $g$ denotes gas and $l$ denotes liquid.

Figure 1

Figure 1.RB convection with bubbles on the hot plate for $\mbox{Ra} = 10^8$, $\mbox{Pr}=4.38$, $S_0=0.18$, $\tilde {h}=0.02$ and $n=144$: (a) volume rendering of a snapshot of the thermal structures, (b) horizontal slice at the height of the lower (hot) BL thickness and (c) mean (over time and space) temperature profile with an inset showing thermal structures inside one bubble. The temperature field is colour-coded and the interface between liquid and gas is marked in green. As seen from the mean temperature profile in (c), due to the bubbles the mean centre temperature $\bar {\theta }=0.461$ is lower than the average temperature $1/2$ of the top and bottom plates (dashed black line).

Figure 2

Figure 2.Nusselt number normalised by that in the single-phase system: (a) $\mbox{Nu}/\mbox{Nu}_s$ as a function of the relative bubble-covered area $S_0$, where the (relative) bubble height $\tilde {h}=0.02$ and the bubble number $n=40$; (b) $\mbox{Nu}/\mbox{Nu}_s$ as a function of $h/\lambda$ for $S_0=0.32$ and $n=40$, with $\lambda$ being the thermal BL thickness (values taken from the hot bottom BL); (c) $\mbox{Nu}/\mbox{Nu}_s$ as a function of $n$ for $S_0=0.18$ and $\tilde {h}=0.02$, where symbols denote the numerical results and lines the predictions of (4.1) and (5.1a,b)–(5.3), and colours are for $\mbox{Ra}=10^7$ (red), $\mbox{Ra}=3.2\times 10^7$ (blue) and $\mbox{Ra}=10^8$ (black). The orange symbol $+$ and the green symbol $\times$ in (c) denote the cases with random bubbles distribution as shown in (d) and the half-covered distribution as shown in (e). All the other symbols in (a–c) are for the uniform distribution. All error bars and deviations between simulations and predictions are within $5\,\%$.

Figure 3

Figure 3.Mean centre temperature $\bar {\theta }$ as a function of (a) $S_0$, (b) $h/\lambda$ and (c) $n$. All the cases are the same as in figure 2. The dashed line denotes the average temperature $1/2$ of the top and bottom plates. All error bars and deviations between simulations and predictions are within $5\,\%$.

Figure 4

Figure 4.Sketch of the temperature profile near the (a) cold top and (b) hot bottom plate. The red lines denote the temperature profiles, the black lines the mean centre temperature $\bar {\theta }$, the blue lines the solution for pure thermal conduction in the BL, that is, (4.1), and the green dashed line the tangent of (4.1) at the intersection. Here, $\theta ^*$ is the intercept of the tangent. We define the dimensional BL thickness near the hot and cold plates as $\lambda _{hot}$ and $\lambda _{cold}$, respectively, that is, the distance from the black dashed lines to the corresponding plate.

Figure 5

Figure 5.Thermal BL thicknesses $\lambda _{hot}$ (empty symbols) and $\lambda _{cold}$ (filled symbols) of the hot bottom and cold top BLs, respectively, as functions of (a) $S_0$, (b) $h/\lambda$ and (c) $n$. All the cases are the same as in figure 2. All error bars and deviations between simulations and predictions are within $5\,\%$.

Figure 6

Figure 6.(a) Comparison between the mean centre temperature $\bar {\theta }_{sim}$ and the effective temperature $\theta ^*_{sim}$, both taken from simulations. The symbols are the same as in figure 2. The shadow is the zone within ${\pm }5\,\%$. (b) Sketch of the bubble system under consideration and the equivalent single-phase RB system. Here, $\bar {\theta }_{sim}$ and $\theta ^*_{sim}$ are plotted this way to support the existence of the equivalent single-phase system.

Figure 7

Table 2.Comparisons between simulations and predictions at large $\mbox{Pr}=400$. The other parameters are $\mbox{Ra}=10^7$, $S_0=0.32$ and $n=40$.