Hostname: page-component-74656f9884-rdgjk Total loading time: 0 Render date: 2026-11-09T04:07:13.071Z Has data issue: false hasContentIssue false

Ultrashort-pulse MeV positron beam generation from intense Compton-scattering γ-ray source driven by laser wakefield acceleration

Published online by Cambridge University Press:  20 December 2012

W. Luo*
Affiliation:
College of Science, National University of Defense Technology, Changsha, China College of Nuclear Science and Technology, University of South China, Hengyang, China
H.B. Zhuo*
Affiliation:
College of Nuclear Science and Technology, University of South China, Hengyang, China Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, China
Y.Y. Ma
Affiliation:
College of Nuclear Science and Technology, University of South China, Hengyang, China Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, China
X.H. Yang
Affiliation:
College of Nuclear Science and Technology, University of South China, Hengyang, China
N. Zhao
Affiliation:
College of Nuclear Science and Technology, University of South China, Hengyang, China
M.Y. Yu
Affiliation:
Institute for Fusion Theory and Simulation, Department of Physics, Zhejiang University, Hangzhou, China Theoretical Physics I, Ruhr University, Bochum, Germany
*
Address correspondence and reprint requests to: H.B. Zhuo and W. Luo, College of Science, National University of Defense Technology, Changsha 410073, China. E-mail: hongbin.zhuo@gmail.com, hongbin.zhuo@gmail.com
Address correspondence and reprint requests to: H.B. Zhuo and W. Luo, College of Science, National University of Defense Technology, Changsha 410073, China. E-mail: hongbin.zhuo@gmail.com, hongbin.zhuo@gmail.com

Abstract

Intense Compton-scattering γ-ray radiation driven by laser wakefield acceleration (LWFA) and generation of ultrashort positron beams are investigated by Monte Carlo simulation. Using an LWFA driven GeV electron bunch and a 45 femtosecond, 90 mJ/pulse, and 10 Hz Ti:Sapphire laser for driving the Compton scattering, fs γ-ray pulses were generated. The latter have a flux of ≥108/s, peak brightness of ≥1020 photons/(s mm2 mrad2 0.1% bandwidth), and photon energy of 5.9 to 23.2 MeV. The γ-ray pulses then impinge on a thin high-Z target. More than 107 positrons/s in the form of sub-100 fs pulses at several MeV can be produced. Such ultrashort positron pulses can be useful as the pump-probe type positron annihilation spectroscopy as well as in other applications.

Information

Type
Research Article
Copyright
Copyright © Cambridge University Press 2012
Figure 0

Fig. 1. Schematic illustration of positron generation via Compton scattering of laser light off LWFA electron beams (e− beams) and the resulting pair creation. An USUI pump laser is focused onto a gas-filled capillary-discharge waveguide or gas jet to generate an LWFA electron bunch. The X/γ rays are then generated by colliding the USUI electron bunch from LWFA with the light from a TW laser that drives the Compton scattering. After passing through the off-axis parabola, the Compton backscattered γ rays impinge on a thin high-Z target to generate an ultrashort positron pulse.

Figure 1

Table 1. LWFA driven electron beam parameters (Leemans et al., 2006) and Ti:Sa laser-pulse parameters used in the simulation. For comparison, the key parameters of typical linac-based storage rings are also shown

Figure 2

Fig. 2. (a) Total energy spectrum obtained from the MCLCSS code. (b) Temporal profile of the GRP obtained from a Gaussian LWFA electron bunch. The LWFA driven electron beam parameters are: 50 pC charge, 5 nm-mrad emittance, 3 µm (rms) spot sizes, and 2.5% energy spread.

Figure 3

Fig. 3. Total positron flux and the corresponding bunch length as a function of the target thickness, from Monte Carlo simulation with the Geant4 toolkit. The calculation is for the spectrum (dotted curve) in Figure 2a.

Figure 4

Fig. 4. Evolution of the positron spectrum, obtained from Monte Carlo simulation. The calculation corresponds to the spectrum given by the dotted curve shown in Figure 2a, for a 4 mm lead target.