Hostname: page-component-74656f9884-j7cmm Total loading time: 0 Render date: 2026-11-10T16:13:11.701Z Has data issue: false hasContentIssue false

Transient Joule–Thomson cooling during CO2 injection in depleted reservoirs

Published online by Cambridge University Press:  10 October 2024

Lucy E.L. Tweed*
Affiliation:
Institute for Energy and Environmental Flows, University of Cambridge, Cambridge CB3 0EZ, UK Department of Earth Sciences, University of Cambridge, Cambridge CB2 3EQ, UK
Michael J. Bickle
Affiliation:
Department of Earth Sciences, University of Cambridge, Cambridge CB2 3EQ, UK
Jerome A. Neufeld
Affiliation:
Institute for Energy and Environmental Flows, University of Cambridge, Cambridge CB3 0EZ, UK Department of Earth Sciences, University of Cambridge, Cambridge CB2 3EQ, UK Department of Applied Mathematics and Theoretical Physics, University of Cambridge, Cambridge CB3 0WA, UK
*
†Email address for correspondence: lt335@cam.ac.uk

Abstract

The injection of ${\rm CO}_2$ into depleted reservoirs carries the potential for significant Joule–Thomson cooling, when dense, supercritical ${\rm CO}_2$ is injected into a strongly under-pressured reservoir. The resulting low temperatures around the wellbore risk causing thermal fracturing of the well/near-well region or causing freezing of pore waters or formation of gas hydrates which would reduce injectivity and jeopardise well and reservoir integrity. These risks are particularly acute during injection start-up when ${\rm CO}_2$ is in the gas stability field. In this paper we present a model of non-isothermal single-phase flow in the near-wellbore region. We show that during radial injection, with fixed mass injection rate, transient Joule–Thomson cooling can be described by similarity solutions at early times. The positions of the ${\rm CO}_2$ and thermal fronts are described by self-similar scaling relations. We show that, in contrast to steady-state flow, transient flow causes slight heating of ${\rm CO}_2$ and reservoir gas either side of the thermal front, as pressure diffuses into the reservoir. The scaling analysis here identifies the parametric dependence of Joule–Thomson cooling. We present a sensitivity analysis which demonstrates that the primary controls on the degree of cooling are reservoir permeability, reservoir thickness, injection rate and Joule–Thomson coefficient. The analysis presented provides a computationally efficient approach for assessing the degree of Joule–Thomson cooling expected during injection start-up, providing a complement to complex, fully resolved numerical simulations.

Information

Type
JFM Papers
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2024. Published by Cambridge University Press.
Figure 0

Figure 1. Pressure–temperature, $p-T$, phase diagram for ${\rm CO}_2$ showing typical reservoir and well-head conditions. Note that depleted reservoirs fall within the gas stability field of ${\rm CO}_2$. The density contours are constructed using data from the NIST web-book (Linstrom & Mallard 2001, webbook.nist.gov).

Figure 1

Figure 2. Schematic diagram showing injection of ${\rm CO}_2$ into a low-pressure, gas-filled reservoir. Here, $\boldsymbol {x}_W$, $\boldsymbol {x}_T$ and $\boldsymbol {x}_C$ denote the edge of the wellbore, the positions of the thermal front and ${\rm CO}_2$ front, respectively. Schematic temperature fields are shown in red subject to: (i) fluid advection only (dashed), (ii) fluid advection, heat conduction and Joule–Thomson cooling (solid). Here $\Delta T_{JT}$ denotes the maximum Joule–Thomson cooling.

Figure 2

Figure 3. Schematic diagram of a radial ${\rm CO}_2$ injection into a cylindrical ${\rm CH}_4$-filled reservoir with thickness $H$. The ${\rm CO}_2$ and thermal front are denoted $r_C$ and $r_T$, respectively.

Figure 3

Table 1. Reference reservoir properties, fluid properties and non-dimensional variables.

Figure 4

Figure 4. Example transient solutions, calculated using the reference fluid and reservoir properties (see table 1), for pressure, temperature, density and $\textrm {CO}_2$ fraction in the mobile fluid phase, plotted against the similarity variable $\eta$. Solutions are calculated for a cold injection with $T_w=25\,^{\circ }\textrm {C}$. The dotted and dashed lines in the top plot show the uncoupled and linearised pressure field solutions at 1 year. The positions of $\eta _W(t)$ at the various times are marked by ‘x’. The positions of $\eta _T$, $\eta _M$, and $\eta _C$ are marked by the vertical blue, orange and grey lines, respectively.

Figure 5

Figure 5. Example transient solutions, calculated using the reference fluid and reservoir properties (see table 1), for pressure, temperature, density and $\textrm {CO}_2$ fraction in the mobile fluid phase, plotted against the radial distance $r$. Solutions are calculated for (a) a cold injection at $25\,^{\circ }\textrm {C}$, and (b) a hot injection at $75\,^{\circ }\textrm {C}$. The steady-state solutions, calculated using the wellbore densities at the three time intervals, are plotted in dashed lines for comparison.

Figure 6

Figure 6. Plots of (a) the rate of pressure buildup in the solid frame $\partial p/\partial t$, (b) the rate of temperature change $\partial T/\partial t$, (c) the rate of fluid density increase $\partial {\rho _f}/\partial t$, (d) the material derivative of pressure in the fluid frame ${\textrm {D}p}/{\textrm {D}t}$, (e) the material derivative of temperature ${\textrm {D}T}/{\textrm {D}t}$ and ( f) the material derivative of fluid density ${\textrm {D}\rho _f}/{\textrm {D}t}$. All rates are calculated for a cold injection at $25 \,^{\circ }\textrm {C}$. The thermal front, temperature maximum and $\textrm {CO}_2$ front are marked by blue, red and grey vertical lines, respectively.

Figure 7

Figure 7. Phase diagram of $\textrm {CO}_2$ with contours of $\mathcal {J} = {\alpha _f\mu _{JT}}/{\beta _f}$ calculated using the CoolProp library (Bell et al.2014) for pure $\textrm {CO}_2$. At the critical point $(\alpha _f, \beta _f)\rightarrow \infty$ such that $\mathcal {J}=1$.

Figure 8

Figure 8. Sensitivity analysis showing parametric controls on pressure and temperature fields of (a) volumetric heat capacity $\varGamma$, (b) scaled isentropic temperature gradient $\mathcal {A}$, (c) scaled Joule–Thomson coefficient $\mathcal {J}$, (d) Thermal Péclet number $Pe$, (e) scaled wellbore pressure gradient $\chi$, ( f) wellbore temperature $\mathcal {T}_w$. The black lines show the reference case for injection at $75\,^{\circ }\textrm {C}$, and the coloured lines are runs with independently varied parameter values. In plots (a–f) only a single parameter is changed at a time.

Figure 9

Figure 9. The $p-T$ phase diagram of $\textrm {CO}_2$ showing the liquid–gas phase transition in the solid black line, and the critical pressure and temperature in the dashed black lines. Contours of (a) $\varGamma$, (b) $\mathcal {A}$, (c) $\mathcal {J}$ and (d) $\chi$ calculated using the CoolProp library.

Figure 10

Figure 10. The $p-T$ phase diagram of $\textrm {CO}_2$, with the liquid–gas phase transition in solid black line, and the critical pressure and temperature marked in dashed black lines. The phase boundaries for $\textrm {CO}_2$ and $\textrm {CH}_4$-hydrate and pure H$_2$O ice are marked, with the freezing window shaded in blue. The $p-T$ trajectories for the low-$T$ ($T_W=25^{\circ }$C) and high-$T$ ($T_W=75\,^{\circ }\textrm {C}$) injections are shown at 3 different times. The dashed lines show a low-$T$ injection with a higher injection rate. The wellbore pressure and temperature are marked by the open circles and the far-field reservoir conditions are marked by the closed circle.