Analysis of regular and small samples at Tandem Laboratory, Uppsala University: 10 years of operation using a MICADAS

Published online by Cambridge University Press:  19 October 2026

Melanie Mucke*
Affiliation:
Tandem Laboratory, Uppsala University , Sweden
Maximilian Rughöft
Affiliation:
Tandem Laboratory, Uppsala University , Sweden
Jonas Balkefors
Affiliation:
Tandem Laboratory, Uppsala University , Sweden
Karl Håkansson
Affiliation:
Tandem Laboratory, Uppsala University , Sweden
Daniel Primetzhofer
Affiliation:
Tandem Laboratory, Uppsala University , Sweden Department of Physics and Astronomy, Uppsala University, Sweden
*
Corresponding author: Melanie Mucke; Email: melanie.mucke@physics.uu.se
Rights & Permissions [Opens in a new window]

Abstract

We report on 10 years of operation of a MICADAS compact tandem accelerator for radiocarbon (14C) analysis at the Tandem Laboratory national research infrastructure at Uppsala University comprising analysis of over 40,000 samples. Based on the large number of analyzed samples and associated references, we perform an analysis of the target scatter of employed IAEA-C7 and SRM-4990C-standards. As a result, we show how the target scatter deduced from a single magazine run is falling below the long-term statistical average, which can result in a systematic uncertainty in 14C results obtained from such runs. We also discuss effects of sample size on current and potential corrections for contamination or non-linearities in the measurement for standard samples spanning a wide range of activity levels, down to below 10 µg C equivalent. Finally, we discuss an observed mass dependence of stable isotope ratios in IRMS, which, if not measured by the accelerator itself, could impact 14C determination.

Information

Type
Conference Paper
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2026. Published by Cambridge University Press on behalf of University of Arizona
Figure 0

Figure 1. Panel A: Histogram of 14C age of C7 reference samples measured with MICADAS from 2015 to 2025. The Gaussian fit yields an average of (5646 ± 33) BP. Panel B: Target scatter values for 52 consecutive magazines measured during 2024 and 2025 as determined by using the “6-Ox-method” (short term) or the long-term observation (see section 2.1 for details). Panel C: Comparison of resulting uncertainties of C7-age in calendar years (1σ) determined via “6-Ox-method” (left) and long-term observation (right), respectively. Panel D: Comparison of δ13C values for C7-standards measured in an IRMS and MICADAS. Both distributions illustrate high accuracy (consensus value C7: δ13C=(−14.48±0.21)${{\rm{\delta }}^{13}}{\rm{C}} = \left( { - 14.48{\rm{\;}} \pm 0.21} \right)$‰) but the measurement precision of the IRMS is significantly higher than that of the MICADAS.

Figure 1

Figure 2. Dependency of measured 13C current on carbon mass for small samples dated using the MICADAS (blue dots, 2014–2025) in comparison to using the 5 MV NEC Pelletron (red dots, 2001–2014), for 6679 samples each, on a log-log scale.

Figure 2

Figure 3. Comparison of F14C for two mass-series of OxII samples from two test magazines, with (filled symbols) and without (open symbols) mass correction according to the contamination model (see Eq. 2). Red and blue curves correspond to badly vs. well-adjusted Faraday cups. Error bars are purely statistical and were scaled from measured to corrected data proportional to the change in F14C.

Figure 3

Figure 4. F14C for mass series of standard sample materials used for calibration and control of small sample dating: C6, OxII, salmon DNA, C7 and C2. The data is current-corrected using BATS and mass-corrected using the contamination model (see section 2.2).

Figure 4

Figure 5. Panels A–D: IRMS measurements on protein standard casein (B2155, Elemental Microanalysis Ltd). Data for stable isotope δ13C are shown in panel A and the corresponding histograms in panel C, data for δ15N in panel B and histograms in panel D. Uncorrected measurement data is shown in red, corrected data is shown in blue. Data sets of one example week are highlighted as large dots.