Progressive cardiac strangulation by an epicardial lead in a single-ventricle patient: a case report

Published online by Cambridge University Press:  06 February 2026

Eun Chae Kim
Affiliation:
Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Jongno-gu, Seoul, Korea
Hyeok Sang Woo
Affiliation:
Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Jongno-gu, Seoul, Korea
Jae Gun Kwak*
Affiliation:
Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Jongno-gu, Seoul, Korea Department of Thoracic and Cardiovascular Surgery, College of Medicine, Seoul National University, Jongno-gu, Seoul, Korea
*
Corresponding author: Jae Gun Kwak; Email: switch.surgeon@gmail.com
Rights & Permissions [Opens in a new window]

Abstract

We report a 24-year-old male with functional single ventricle who developed ventricular dysfunction associated with strangulation by a previous epicardial pacemaker lead. During conversion to dual-chamber pacing, the constricting ventricular lead was removed, with intraoperative echocardiography demonstrating improvement in apical contraction. Relief of mechanical compression, together with restoration of atrioventricular synchrony, likely contributed to the recovery of ventricular function.

Information

Type
Case Report
Copyright
© The Author(s), 2026. Published by Cambridge University Press
Figure 0

Figure 1. Pictures from the operation. (a) Injured pacemaker lead. (b) White arrows: previous ventricular lead, encircling ventricular apex; black: diaphragm. (c) White dotted: ventricular apex. (d) White triangles: ventricular apical area indentation slightly improved but remained with the fibrotic band even after the removal of the previous ventricular lead.

Figure 1

Figure 2. Chest X-ray of the patient in chronological order. (a) after inserting the pacemaker at 13 months of age. (b) at age 5 year. (c) at age 17 years. (d) at age 21 years. The position of the pacemaker lead appears to have shifted over time.