Hostname: page-component-74656f9884-54qdv Total loading time: 0 Render date: 2026-11-10T02:26:01.523Z Has data issue: false hasContentIssue false

Diffusive growth of successive bubbles in confinement

Published online by Cambridge University Press:  06 November 2019

Álvaro Moreno Soto*
Affiliation:
Physics of Fluids Group and Max Planck Center Twente, MESA+ Institute and J. M. Burgers Centre for Fluid Dynamics, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands Department of Mechanical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, USA
Detlef Lohse
Affiliation:
Physics of Fluids Group and Max Planck Center Twente, MESA+ Institute and J. M. Burgers Centre for Fluid Dynamics, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
Devaraj van der Meer*
Affiliation:
Physics of Fluids Group and Max Planck Center Twente, MESA+ Institute and J. M. Burgers Centre for Fluid Dynamics, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
*
†Email addresses for correspondence: a.morenosoto@utwente.nl, d.vandermeer@utwente.nl
†Email addresses for correspondence: a.morenosoto@utwente.nl, d.vandermeer@utwente.nl

Abstract

We analyse how a succession of single bubbles extracts dissolved gas from a liquid solution while they grow and detach in a confinement induced by the presence of lateral walls. Like bubbles growing on a liquid-immersed unconfined surface, these bubbles absorb the dissolved gas in the liquid around them and hence deplete their surroundings. The supersaturation level, $\unicode[STIX]{x1D701}$, stands out as the main parameter which determines the diffusive bubble dynamics, both in the confined and unconfined scenarios. For slightly supersaturated solutions, the bubble evolution is rather similar for the two cases. We observe nonetheless mildly higher concentration gradients within confinement due to the lack of gas renewal. This causes a slightly enhancement of density-driven convection as compared to the unconfined case, which results in a higher mass transfer rate towards the bubble and a somewhat faster long-term gas depletion. For larger supersaturations, the onset of natural convection is inhibited by the presence of the confinement. Confinement promotes the gas mixing within the cavity as well. These two effects combined result in a slower depletion in the confined case as compared to the unconfined one. The two opposite behaviours for small and large supersaturation suggest that there must be a transition in between the two scenarios. The cross-over has been estimated to occur at $\unicode[STIX]{x1D701}\approx 0.17$. We propose a modified depletion model which accounts for the confined configuration and its effect on the effective area through which gas diffuses into the bubble. The model can accurately describe the experimental results and sheds more light on the origin of the depletion effect due to the successive bubble growth.

Information

Type
JFM Papers
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright
© The Author(s) 2019
Figure 0

Figure 1. (a) Schematic (not to scale) of the experimental geometry with the substrate holding the cylindrical lateral confinement of radius $R_{c}=2.5~\text{mm}$ and height $H=10~\text{mm}$ around the growing bubble. The single bubble grows from the superhydrophobic pit of radius $R_{p}=50~\unicode[STIX]{x03BC}\text{m}$ according to the imposed supersaturation level $\unicode[STIX]{x1D701}$. Once the bubble detaches, a subsequent one nucleates and the succession continues. (b) Snapshot of one of the experiments. The contour of the cylinder base surrounding the bubble can be appreciated. The position of the superhydrophobic pit from which the bubble nucleates and grows is also indicated. One clearly detects the neck joining the entrapped gas in the pit and the bubble growing outside (Moreno Soto et al.2017).

Figure 1

Figure 2. (a) Dimensionless radius $\unicode[STIX]{x1D716}$ plotted against the dimensionless square root of time $x$ for subsequent bubbles in confinement. The different colours represent different supersaturation levels $\unicode[STIX]{x1D701}$, namely, blue for 0.15, red for 0.25 and yellow for 0.47. The different symbols stand for the order of the bubble in the succession, namely circles for the first bubble and diamonds for the fifth, whereas (3.2) is plotted as solid lines in the corresponding colours. The inset shows the unscaled data for the time evolution of the bubble radius $R$ prior to the non-dimensionalisation. (b) Derivative of the dimensionless radius versus the dimensionless square root of time. The same colour symbol coding as in panel (a) applies here. Equation (3.2) coincides for the three different $\unicode[STIX]{x1D701}$ and is represented as a black solid line. Note that increasing $\unicode[STIX]{x1D701}$ causes an earlier and intensified onset of convection.

Figure 2

Figure 3. (a) Sherwood number $Sh$ against Rayleigh number $Ra$ for the same bubbles as in figure 2 plotted in logarithmic scale. Depletion can already be appreciated for the fifth bubble, which is clearly separated from the first curve. To compare, the theoretical relation for natural convection around bubbles in an infinite medium, equation (3.4), is shown. The experimental curves lie below but ‘parallel’ (see main text) to the theoretical expression, indicating that, indeed, natural convection is driving the bubble growth from the middle stages of its growth onwards. (b) The depletion number $\unicode[STIX]{x1D6F6}$ decreases for increasing $\unicode[STIX]{x1D701}$, as expected from an enhanced bubble growth rate. The solid lines represent the best theoretical approximation for each $\unicode[STIX]{x1D701}$ according to (3.7).

Figure 3

Figure 4. (a) Dimensionless radius $\unicode[STIX]{x1D716}$ plotted against the dimensionless square root of time $x$ for experiments with $\unicode[STIX]{x1D701}=0.15$. In blue, the bubbles grow under confinement, whereas in red, the bubbles grow in an open medium. Different symbols are used to indicate the first (circle), fifth (diamond) and tenth (star) bubbles in the succession. The curves within the same succession deviate from each other due to the effect of depletion. (b) Derivative of the dimensionless radius versus the dimensionless square root of time. The effects of depletion are very noticeable in this data representation. The respective curves with and without confinement seem to run parallel, indicating a similar strength in the onset of convection. In (a,b), the solid line corresponds to (3.2).

Figure 4

Figure 5. (a) Evolution of the dimensionless radius $\unicode[STIX]{x1D716}$ for $\unicode[STIX]{x1D701}=0.47$ and (b) corresponding derivative versus the dimensionless square root of time $x$. The solid lines correspond to (3.2). There has been an inversion of some of the behaviour observed for $\unicode[STIX]{x1D701}=0.15$ (figure 4): now, the first confined bubble grows slower than that in the unconfined case. However, due to a stronger depletion for the unbounded bubble, the subsequent bubbles in confinement grow faster.

Figure 5

Figure 6. (a) The evolution of the depletion number $\unicode[STIX]{x1D6F6}_{n}$ as a function of time for $\unicode[STIX]{x1D701}=0.15$ shows that for the first five bubbles in the succession, bubbles in the confined and open cases deplete their surroundings in very similarly manner. In the long term, depletion is more affected by the minute stronger convective effect occurring in confinement. The solid lines in the corresponding colours represent the theoretical behaviour indicated by (3.7) for the confined domain (blue) and the model by Moreno Soto et al. (2017) for the non-confined (red). (b,c) The depletion number $\unicode[STIX]{x1D6F6}_{n}$ for (b) $\unicode[STIX]{x1D701}=0.25$ and (c) $\unicode[STIX]{x1D701}=0.47$ strongly decreases for the unconfined scenario as compared to the bounded domain due to the full development of the buoyant depleted boundary layer. Increasing $\unicode[STIX]{x1D701}$ provides the same qualitative behaviour. Note that for all the cases, the bubble frequency for the confined case is always larger than for the unconfined case. This originates from the accumulation of time mismatch due to the slight difference in the final $R_{det}$ and the different ways in which the buoyant depleted boundary layer develops in the two cases.