Hostname: page-component-74656f9884-npj9w Total loading time: 0 Render date: 2026-11-07T01:09:56.703Z Has data issue: false hasContentIssue false

Structure design and kinematic performance of the deployable translational parallel tape-spring manipulator

Published online by Cambridge University Press:  22 March 2024

Hu Liu
Affiliation:
School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China
Yawen Qin
Affiliation:
School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China
Yi Yang*
Affiliation:
School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China
*
Corresponding author: Yi Yang; E-mail: yiyangshu@t.shu.edu.cn.
Rights & Permissions [Opens in a new window]

Abstract

A deployable manipulator has the characteristics of a small installation space and a large workspace, which has great application prospects in small unmanned platforms. Most existing deployable manipulators are designed based on rigid links, whose complexity and mass inevitably increase sharply with increasing numbers of rigid links and joints. Inspired by the remarkable properties of tape springs, this paper proposes novel deployable parallel tape-spring manipulators with low mass, simple mechanics, and a high deployed-to-folded ratio. First, a double C-shaped tape spring is presented to improve the stability of the structure. The combined fixed drive component (CFDC) and combined mobile drive component (CMDC) are designed. Then, novel 2-DOF and 3-DOF deployable translational parallel manipulators are proposed based on the CFDC and CMDC, and their degrees-of-freedom (DOFs), kinematics, and stability are analyzed. The coiled tape spring is regarded as an Archimedean spiral, which can significantly improve the accuracy of kinematic analysis. The correction coefficient of the Euler formula is obtained by comparison with simulation results and experimental results. Furthermore, the stability spaces of the 2-DOF and 3-DOF deployable parallel manipulators are given. Finally, a prototype is fabricated, and experiments are conducted to validate the proposed design and analysis.

Information

Type
Research Article
Copyright
© The Author(s), 2024. Published by Cambridge University Press
Figure 0

Figure 1. Diagram of a double C-shaped tape spring. (a) Cross-section; (b) Cross-section after folding; (c) Coiled tape spring.

Figure 1

Figure 2. Design principle of the MDC. (a) Localized folded configuration; (b) Folded segment of the tape spring sliding; (c) Schematic diagram of MDC.

Figure 2

Figure 3. The detailed structure of the mobile drive component.

Figure 3

Figure 4. Fixed drive component. (a) Structure; (b) Constant tension mechanism.

Figure 4

Figure 5. Combined mobile drive component.

Figure 5

Figure 6. 2-DOF double V-shaped deployable parallel manipulator.

Figure 6

Figure 7. Schematic diagram of the mechanism. (a). Mobile drive component, (b). Fixed drive component, (c). Single V-shaped configuration, (d). Double V-shaped configuration.

Figure 7

Figure 8. Schematic diagram of the 2-DOF manipulator.

Figure 8

Figure 9. Schematic diagram of the mechanism consisting of two 2-DOF manipulators.

Figure 9

Figure 10. Detailed structure of the 3-DOF deployable tape-spring manipulator.

Figure 10

Figure 11. Kinematic model of the 2-DOF deployable parallel tape-spring manipulator.

Figure 11

Figure 12. The relationship between s1 and the rotation angles of FDC $\theta _{1}$ in two cases.

Figure 12

Figure 13. (a) Workspace of the 2-DOF manipulator; (b) Variation of r1 in the workspace.

Figure 13

Figure 14. Condition number of the Jacobian matrix under different conditions.

Figure 14

Figure 15. Kinematic model of the 3-DOF deployable tape-spring manipulator.

Figure 15

Figure 16. Workspace of the 3-DOF deployable tape-spring manipulator.

Figure 16

Figure 17. Cross-sectional geometry of the double C-shaped tape spring.

Figure 17

Figure 18. The second moment of the area corresponding to different α.

Figure 18

Figure 19. Deformation diagram of a double C-shaped tape spring. (a) l = 490 mm; (b) l = 540 mm; (c) l = 590 mm; (d) l = 640 mm.

Figure 19

Figure 20. Configuration of the buckling experiment.

Figure 20

Figure 21. F-$\lambda$curves of double C-shaped tape springs with different lengths: (a) l = 490 mm; (b) l = 540 mm; (c) l = 590 mm; (d) l = 640 mm.

Figure 21

Table I. Critical buckling loads of the tape springs.

Figure 22

Table II. Comparison of critical loads for the tape spring obtained by three methods.

Figure 23

Figure 22. Comparison between the modified Euler formula and experimental values.

Figure 24

Figure 23. Stability space of the 2-DOF manipulator.

Figure 25

Figure 24. Stability space of the 3-DOF manipulator.

Figure 26

Figure 25. Prototype of the 2-DOF double V-shaped tape-spring manipulator.

Figure 27

Figure 26. Stability experiment at four boundary positions: (a) (0, −200); (b) (450, −500); (c) (−450, −500); (d) (−100, −1150).

Figure 28

Figure 27. Grasping experiment for the 2-DOF double V-shaped tape spring manipulator. (a) Initial state; (b) Deploying; (c) Grasping; (d) Moving to the right; (e) Releasing; (f) Retracting.