Development of knee exoskeleton for capturing energy from human knee motion

Published online by Cambridge University Press:  17 July 2023

Bing Chen
Affiliation:
School of Mechanical Engineering, Hefei University of Technology, Hefei, China Intelligent Interconnected Systems Laboratory of Anhui Province, Hefei University of Technology, Hefei, China
Jialiang Tan
Affiliation:
School of Mechanical Engineering, Hefei University of Technology, Hefei, China
Chenpu Shi
Affiliation:
School of Mechanical Engineering, Hefei University of Technology, Hefei, China
Bin Zi*
Affiliation:
School of Mechanical Engineering, Hefei University of Technology, Hefei, China Intelligent Interconnected Systems Laboratory of Anhui Province, Hefei University of Technology, Hefei, China
*
Corresponding author: Bin Zi; E-mail: zibinhfut@163.com
Rights & Permissions [Opens in a new window]

Abstract

In this paper, the design and experimental validation of a knee exoskeleton are presented. The exoskeleton can capture the negative work from the wearer’s knee motion while decreasing the muscle activities of the wearer. First, the human knee biomechanics during the normal walking is described. Then, the design of the exoskeleton is presented. The exoskeleton mainly includes a left one-way transmission mechanism, a right one-way transmission mechanism, and a front transmission mechanism. The left and right one-way transmission mechanisms are designed to capture the negative work from the wearer’s knee motion in the stance and swing phases, respectively. The front transmission mechanism is designed to transform the bidirectional rotation of the wearer’s knee joint into the generator unidirectional rotation. Additionally, the modeling and analysis of the energy harvesting of the exoskeleton is described. Finally, walking experiments are performed to validate the effectiveness of the proposed knee exoskeleton. The testing results verify that the developed knee exoskeleton can output a maximum power of 5.68 ± 0.23 W and an average power of 1.45 ± 0.13 W at a speed of 4.5 km/h in a gait cycle. The average rectus femoris and semitendinosus activities of the wearers in a gait cycle are decreased by 3.68% and 3.40%, respectively.

Information

Type
Research Article
Copyright
© The Author(s), 2023. Published by Cambridge University Press
Figure 0

Figure 1. Human normal gait cycle. A human gait cycle comprises a stance phase and a swing phase, and the stance phase accounts for approximately 60% of a normal gait cycle.

Figure 1

Figure 2. Joint angle and torque of the human knee in a normal gait cycle. For a human knee joint, a normal gait cycle can be divided into a stance flexion stage, a stance extension stage, a pre-swing stage, a swing flexion stage, and a swing extension stage.

Figure 2

Figure 3. Joint power of the human knee in a normal gait cycle. The negative work can be generated from the knee motion in the stance flexion, pre-swing, and swing extension stages.

Figure 3

Figure 4. Developed knee exoskeleton. The exoskeleton is primarily composed of a shank brace, a thigh brace, a left one-way transmission mechanism, a right one-way transmission mechanism, and a front transmission mechanism. (a) Mechanical structure of the knee exoskeleton. (b) Prototype of the knee exoskeleton.

Figure 4

Figure 5. Mechanical structure of the key modules of the knee exoskeleton. (a) Thigh and shank braces. (b) Left one-way transmission mechanism. (c) Right one-way transmission mechanism. (d) Front transmission mechanism.

Figure 5

Figure 6. Negative work capturing during the stance flexion, pre-swing, and swing extension stages of a gait cycle. During the stance flexion, pre-swing, and swing extension stages, the leg in the dashed line is at the beginning of this stage, and the leg in the solid line is at the end of this stage.

Figure 6

Figure 7. Experimental setup of the walking experiments. The treadmill is used to control the walking speed. The oscilloscope is used to measure the voltage of the external electrical resistance. The EMG system is used to collect the muscles activities. The motion capture system is used to collect the participants’ knee joint angles.

Figure 7

Figure 8. Power produced by the knee exoskeleton. The exoskeleton captures the negative work from the wearer’s knee motion during the stance flexion, pre-swing, and swing extension stages of a gait cycle.

Figure 8

Figure 9. Knee joint angles of the participants in the three groups of walking experiments. p < 0.05 indicates statistically significant difference, and p > 0.05 indicates no statistically significant difference. (a) Knee joint trajectories. (b) Statistical analysis results of the overall knee joint trajectories.

Figure 9

Figure 10. Muscle activities of the rectus femoris and semitendinosus of the participants in the three groups of walking experiments. p < 0.05 indicates statistically significant difference, and p > 0.05 indicates no statistically significant difference. (a) Rectus femoris activities. (b) Statistical analysis results of the overall rectus femoris activities. (c) Semitendinosus activities. (d) Statistical analysis results of the overall semitendinosus activities.

Figure 10

Table I. Comparison between the developed knee exoskeleton and other studies.