Hostname: page-component-74656f9884-npj9w Total loading time: 0 Render date: 2026-11-07T04:52:17.684Z Has data issue: false hasContentIssue false

Two-dimensional modelling of transient capillary driven damped micro-oscillations and self-alignment of objects in microassembly

Published online by Cambridge University Press:  08 January 2021

Adam Chafaï*
Affiliation:
Transfers, Interfaces and Processes (TIPs), Université Libre de Bruxelles, Avenue F.D. Roosevelt 50, CP 165/67, 1050 Brussels, Belgium
Y. Vitry
Affiliation:
Transfers, Interfaces and Processes (TIPs), Université Libre de Bruxelles, Avenue F.D. Roosevelt 50, CP 165/67, 1050 Brussels, Belgium
S. Dehaeck
Affiliation:
Transfers, Interfaces and Processes (TIPs), Université Libre de Bruxelles, Avenue F.D. Roosevelt 50, CP 165/67, 1050 Brussels, Belgium
F. Gallaire
Affiliation:
Laboratory of Fluid Mechanics and Instabilities (LFMI), Ecole Polytechnique Fédérale de Lausanne, MED 2 2926, Station 9, 1015 Lausanne, Switzerland
B. Scheid
Affiliation:
Transfers, Interfaces and Processes (TIPs), Université Libre de Bruxelles, Avenue F.D. Roosevelt 50, CP 165/67, 1050 Brussels, Belgium
P. Colinet
Affiliation:
Transfers, Interfaces and Processes (TIPs), Université Libre de Bruxelles, Avenue F.D. Roosevelt 50, CP 165/67, 1050 Brussels, Belgium
P. Lambert
Affiliation:
Transfers, Interfaces and Processes (TIPs), Université Libre de Bruxelles, Avenue F.D. Roosevelt 50, CP 165/67, 1050 Brussels, Belgium
*
†Email address for correspondence: adam.chafai@ulb.be

Abstract

In the fields of microgripping and microassembly, the self-alignment motion of a solid micro-object linked by a liquid meniscus to a substrate or a tool is an inexpensive way to overcome the current limitations of the assembly processes at microscale by getting rid of the positioning actuators. Original models providing a dynamical description of the capillary self-alignment of an $L\times D \times d$ chip are reported, as well as experimental results as evidence of their validity. The first two models describe the liquid and the solid physics in two dimensions. Both include nonlinearities and describe the coupling between a laminar flow and a solid structure. The fluid–solid coupling is ensured by the boundary conditions at their surface of contact and by the forces the liquid and the solid apply on each other. Both models yield the shift, lift and tilt modes of deformation of the liquid meniscus. Equations are first numerically solved by using a finite element method (model 1). By approximating the menisci with spherical caps, a geometrical model is then presented (model 2). Next, for small oscillations and thin liquid layers, the equations are linearised. The solution to the semianalytical three degrees of freedom (3-DOF) modal analysis is thus obtained (model 3). Finally, a semianalytical 1-DOF model is presented and numerically solved by considering a one-dimensional motion for the solid object (model 4). Solutions for models 1, 3 and 4 are computed and show good agreement with the experimental measurements. Yet, the remaining deviations are investigated to identify their origin.

Information

Type
JFM Papers
Copyright
© The Author(s), 2021. Published by Cambridge University Press
Figure 0

Figure 1. Usual terminology used in capillary gripping and self-assembly fields. (a) Modes of deformation of a liquid meniscus bounding two solid objects; (b) one-dimensional (1-D) uncoupled model for the shift where the 1-D linear fluid velocity distribution is described as $\boldsymbol {v}_x=\dot {x}z/h \, \boldsymbol {1}_x$; (c) 1-D coupled model for the shift where $\boldsymbol {v}_x=f(t,z) \, \boldsymbol {1}_x$; (d) two-dimensional (2-D) coupled model for shift, tilt, lift with a two degrees of freedom (2-DOF) fluid, $\boldsymbol {v}_x$ and $\boldsymbol {v}_z$.

Figure 1

Table 1. Overview of the dynamical self-alignment models and their experimental validations. The terms ‘1-D uncoupled’, ‘1-D coupled’ and ‘2-D coupled’ refer to figure 1(b–d), respectively. The following abbreviations are used: rectangular (Rect.); finite element method (FEM).

Figure 2

Figure 2. Illustration of 2-D self-alignment motion of a rectangular pad linked to a similarly shaped substrate by a liquid meniscus. The grey dashed lines sketch the rest state of the system. Here $\boldsymbol {F}_{T_P}$ and $\boldsymbol {F}_{T_Q}$ are the tension forces applied on the triple line interface, $P_g$ is the ambient pressure and point $G$ is the centre of mass of the rectangular pad. Its coordinates along $\boldsymbol {1}_x$ and $\boldsymbol {1}_z$ are the shift and lift DOF. Here $\theta$ (the tilt) is the third degree of freedom of the pad. The meniscus, respectively, forms the angles $\phi +\varTheta _P$ and $\psi -\varTheta _Q$ at points $P$ and $Q$ with the vertical axis. Angles $\varTheta _P$ and $\varTheta _Q$ expressed as functions of the DOF $x_G$, $z_G$ and $\theta$ can be found in appendix B. These two angles are positive when the solid shifts rightwards.

Figure 3

Figure 3. Geometrical parameterisation for the calculation of the excess capillary pressure with respect to the ambient on the left-hand side of the meniscus. A similar parameterisation is adopted for the right-hand side, i.e. at point $Q$, using $\psi$ instead of $\phi$. As the solid shifts towards the left, angles $\varTheta _P$ and $\varTheta _Q$ are negative.

Figure 4

Figure 4. Experimental set-up for the motion tracking of a patterned chip. The liquid meniscus has been distorted by applying an initial shift on the coated chip thanks to the actuator. At time $t=0$, the actuator retracts faster than the chip subjected to the self-alignment effect.

Figure 5

Figure 5. Two of the tracking routine steps. (a) Top view of a randomly etched glass chip. Its centre of mass $G$ is obtained by finding the edges. The red crosses show the resulting corner coordinates. Here $G$ is located at the centre of the green square. The position of the observed region of the chip (blue box) is found by cross-correlation. The white circle represents the centre of the observed region. The coordinates of the centre of mass are thereby known in the observed region of the chip. (b) Observed region of the chip. Each one of the green points is a tracked feature. The displacements of these points are used to retrieve the position of the centre of mass by the least squares method.

Figure 6

Figure 6. Typical damped oscillations obtained with the experimental set-up for a $0.08$ mm initial shift in the $\boldsymbol {1}_x$ direction. Period $T$ (s) and damping time constant $\tau$ (s) are specified in the $f(t)=x_{G_0}\cos ((2{\rm \pi} /T)\, t)\exp (-t/\tau )$ least squares fitting functions. (a) Shift motions in $\boldsymbol {1}_x$ and $\boldsymbol {1}_y$ directions; (b) COMSOL simulation corresponding to shift along $\boldsymbol {1}_x$; (c) focus on the shift motion in the $\boldsymbol {1}_y$ direction, extracted from (a); (d) Twist motion.

Figure 7

Table 2. Physical parameters input into the models for solving.

Figure 8

Figure 7. (a) Increase in the damping time constant with the meniscus height. The damping time constant $\tau$ is extracted from the damped sinusoidal oscillations fitting formula $f(t)=x_{G_0}\cos ((2{\rm \pi} /T)t)\exp (-t/\tau )$. Comparison between experimental results obtained with a square chip and results from models. Bond numbers are given for each value of $h_0$; (b) relative error between experimental and theoretical results.

Figure 9

Figure 8. (a) Sketch showing the chip being pushed with a misalignment $S$ (mm) along $\boldsymbol {1}_y$ in order to excite non-negligible 3-D deformations of the meniscus; (b) evolution of the relative error for a fixed volume of liquid ($h_0/L = 0.017$) according to the misalignment between the pushing tip and the centre of mass of the chip.

Figure 10

Figure 9. (a) Increase of the period with the meniscus height and comparison with the models’ predictions; (b) relative error between experimental results and the models.

Figure 11

Figure 10. Sketches closely following the experimental pictures of the meniscus shape in different cut planes. The colour of the meniscus refers to the cut plane in which the liquid is observed. (a) Meniscus shape for the square pads; (b) meniscus shape for the rounded pads; (c) the cut planes in which the pictures have been taken. The $AA'$ cuts the chip parallel to its sides, while $BB'$ cuts it diagonally. (a) Rectangular chip; (b) rounded chip; (c) cut planes.

Figure 12

Figure 11. An example of normalised tilt motion induced by the oscillations in the case of a pure initial shift for the fully numerical 2-D nonlinear and linear models. Here $z_P$ and $z_Q$ vary due to the shift induced tilting of the pad. The 2-D linear model has been solved for $T$ and $\tau$, and a normalised damped sinusoidal function has been plotted.

Chafaï et al. supplementary movie

Movie presenting the experimental set-up and validation steps for the measurement of the capillary driven micro-oscillations.

Download Chafaï et al. supplementary movie(Video)
Video 19.9 MB