The second revolution in atom probe tomography

Published online by Cambridge University Press:  17 February 2012

Thomas F. Kelly
Affiliation:
Cameca Instruments, Inc., Madison, WI; thomas.kelly@ametek.com.
David J. Larson
Affiliation:
Cameca Instruments, Inc., Madison, WI; david.larson@ametek.com.

Abstract

There has been explosive growth in the performance and consequential adoption of atom probe tomography in the past decade, which was fueled by the development of the commercial local-electrode atom probe (LEAP) and technologies for specimen preparation. The LEAP introduced to atom probes orders-of-magnitude increases in data collection rates and field of view while improving mass resolution and greatly improving ease of use. These developments constitute the second revolution in the field since the invention of the atom probe in 1967 and atom probe tomography in 1973: the invention of the three-dimensional atom probe was the first revolution. This article seeks to put this second revolution into historical perspective by recounting the essential developments that led to this point. In particular, the role of Erwin Müller, the inventor of the atom probe and related instruments, is highlighted. From the invention of the field emission electron microscope to the field ion microscope to the atom probe and beyond, he created a field of microscopy that is thriving today. Next, the state of the art in atom probe instrumentation is illustrated with a current application. Finally, a brief look toward future developments is provided, which may include superconducting detectors and integration of atom probes with transmission electron microscopes.

Information

Type
Research Article
Copyright
Copyright © Materials Research Society 2012
Figure 0

Figure 1. Ancestry of the local-electrode atom probe.

Figure 1

Figure 2. Photograph of Erwin W. Müller (1911–1977)—father of high-(electric) field nanoscience. Figure courtesy of J.A. Panitz, The University of New Mexico, Department of Physics and Astronomy.

Figure 2

Figure 3. (a) Schematic of the field electron emission microscope (FEEM). (b) FEEM image of <110> tungsten.14 The twofold symmetry of this pattern is evident. (c) Schematic of the field ion microscope (FIM). (d) FIM image of <110> tungsten.17,18 The first images of atoms obtained by humans were made on October 11, 1955 by Bahadur and Müller.

Figure 3

Figure 4. Schematic of a short-flight-path atom probe with a local electrode. The detector would be placed close to the specimen to maximize solid angle. If the detector is also capable of modest energy discrimination, then the atom probe (labeled APT) image data may be separated from field ions and a separate field ion microscope (labeled FIM) image may be simultaneously recorded.

Figure 4

Figure 5. A sketch of an electron-beam pulsed atom probe inside the objective lens of a transmission electron microscope. From the 1990 International Field Emission Symposium meeting, Albuquerque, NM. The electron beam would be used for both thermal pulsing and for imaging the tip.

Figure 5

Figure 6. (a) Photograph of the alpha prototype of the commercial local-electrode atom probe (LEAP) at Imago Scientific Instruments (2001). (b) Photograph of a current LEAP 4000 system for comparison with the alpha prototype.

Figure 6

Table I. Comparison of predictions (1990) with reality (2011) for performance of atom probes.

Figure 7

Figure 7. Atom probe tomography analysis of a high-κ + metal gate transistor: gate oxide/source/channel/drain region. (a) Schematic of the transistor (after Mardinly41) and (b) an atom map of the transistor.40

Figure 8

Figure 8. The Atomscope as proposed in the ATOM Project.44,45 Left: A schematic diagram of the electron column with an atom probe component in the objective lens module. Right: Specimen geometry with an integrated local electrode.