Rapid Quantification of Bone Collagen Content by ATR-FTIR Spectroscopy

Published online by Cambridge University Press:  05 January 2016

M Lebon*
Affiliation:
Unité Mixte de Recherche 7194, Histoire Naturelle de l’Homme Préhistorique (HNHP), Centre National de la Recherche Scientifique, Muséum National d’Histoire Naturelle, Université Perpignan Via Domitia – Sorbonne Universités, 17 Place du Trocadéro, F-75116 Paris, France.
I Reiche
Affiliation:
Unité Mixte de Recherche 8220, Laboratoire d’Archéologie Moléculaire et Structurale (LAMS), Centre National de la Recherche Scientifique, Université Pierre et Marie Curie Paris 6 – Sorbonne Universités, CP 225, 4 place Jussieu, F-75005, Paris, France.
X Gallet
Affiliation:
Unité Mixte de Recherche 7194, Histoire Naturelle de l’Homme Préhistorique (HNHP), Centre National de la Recherche Scientifique, Muséum National d’Histoire Naturelle, Université Perpignan Via Domitia – Sorbonne Universités, 17 Place du Trocadéro, F-75116 Paris, France.
L Bellot-Gurlet
Affiliation:
Unité Mixte de Recherche 8233, De la molécule aux nano-objets: réactivité, interactions et spectroscopies (MONARIS), Centre National de la Recherche Scientifique Université Pierre et Marie Curie Paris 6 – Sorbonne Universités, CP 49, 4 place Jussieu, F-75252 Paris, France.
A Zazzo
Affiliation:
Unité Mixte de Recherche 7209, Archéozoologie, Archéobotanique: Sociétés, Pratiques et Environnements, Centre National de la Recherche Scientifique, Muséum National d’Histoire Naturelle, Sorbonne Universités, CP 56, 55 rue Buffon, F-75005 Paris, France.
*
*Corresponding author. Email: lebon@mnhn.fr.
Rights & Permissions [Opens in a new window]

Abstract

Expensive and time-consuming preparation procedures for radiocarbon and stable isotope analyses can be conducted on archaeological bone samples even if no collagen is preserved. Such unsuccessful preparation can lead to the partial destruction of valuable archaeological material. Establishing a rapid prescreening method for evaluating the amount of bone collagen while minimizing the impact of sampling constitutes a challenge for the preservation of archaeological collections. This study proposes and discusses a new methodology to detect and quantify collagen content in archaeological bone samples by attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. A total of 42 Pleistocene to modern bone samples were selected according to their nitrogen content measured using an elemental analyzer. Comparison of collagen content estimation using ATR-FTIR and mass spectrometry reveals that some of the studied samples are contaminated by a nitrogen source coming from the burial environment. Two different FTIR calibration approaches were tested on the uncontaminated samples: peak-to-peak ratio and multivariate regression (PLS). The two approaches yield similar results with a good correlation of ATR-FTIR analyses and N wt% from 0.7 to 4wt% (R²=0.97–0.99; standard error of estimation ±0.22 to 0.25wt%). While collagen content remains difficult to detect in poorly preserved bones (less than ~3wt%), ATR-FTIR analysis can be a fast alternative for sample screening to optimize the sampling strategy and avoid partial destruction of valuable samples that do not contain enough collagen for further analysis.

Information

Type
Research Article
Copyright
© 2016 by the Arizona Board of Regents on behalf of the University of Arizona 
Figure 0

Figure 1 Example of ATR-FTIR spectra with decreasing contents of collagen: modern ox bone, and archaeological bones from Harsova-tell (HAR), Bize-Tournal (BZ-PJ1-09), El Harroura 2 (EH2-20).

Figure 1

Table 1 Measurement of amide 1/PO4, C wt%, N wt%, and C:N ratio and associated standard deviation (SD) and relative standard deviation (RSD). Part of the samples were analyzed before and after NaOH treatment.

Figure 2

Figure 2 Relationship between N content (wt%) and amide/PO4 ratio for archaeological samples. Values obtained before and after NaOH treatment are plotted for SSPM, AGI, and GOL samples.

Figure 3

Figure 3 Effect of the NaOH treatment on the N content and amide I/PO4 ratio of the bone samples from AGI, GOL, and SSPM catacomb.

Figure 4

Figure 4 Comparison of ATR-FTIR spectra before and after NaOH treatment for (a) X84-Sq203-FF and (b) X84-Sq205-FF samples from the SSPM catacomb; (c) subtraction of (a) and (b) spectra.

Figure 5

Figure 5 Linear regression between N content (wt%) and amide I/PO4 ratio for modern and archaeological samples. The dotted line representing the regression obtained for all samples (0 to 4.25%wt N) was used to calculate the LOD and LOQ of the calibration. The solid line representing the linear regression between 0.5–4wt% N was used to establish the relationship between N wt% and the amide I/PO4 ratio.

Figure 6

Figure 6 PLS validation plots of measured N wt% versus ATR-FTIR predicted values for models established on (a) ATR-FTIR spectra for the range 4000–400 cm–1 and (b) on 1st derivative spectra for the range 1900–800 cm–1. Insets present an enlargement of the curves for low concentrations.

Figure 7

Table 2 PLS regression results of N wt% content obtained using ATR-FTIR spectra or 1st derivative spectra on three different spectral ranges. Asterisks (*) indicate the models that are more effective to quantify low concentrations.